Literature DB >> 23229201

Development of multi-planar dose verification by use of a flat panel EPID for intensity-modulated radiation therapy.

Yuji Nakaguchi1, Fujio Araki, Tomohiro Kouno, Takeshi Ono, Kazunari Hioki.   

Abstract

Our purpose in this study was to evaluate the accuracy of a new multi-planar dose measurement method. The multi-planar dose distributions were reconstructed at each depth by convolution of EPID fluence and dose kernels with the use of EPIDose software (SunNuclear). The EPIDose was compared with EPID, MapCHECK (SunNuclear), EDR2 (Kodak), and Monte Carlo-calculated dose profiles. The EPIDose profiles were almost in agreement with Monte Carlo-calculated dose profiles and MapCHECK for test plans. The dose profiles were in good agreement with EDR2 at the penumbra region. For dose distributions, EPIDose, EDR2, and MapCHECK agreed with that of the treatment-planning system at each depth in the gamma analysis. In comparisons of clinical IMRT plans, EPIDose had almost the same accuracy as MapCHECK and EDR2. Because EPIDose has a wide dynamic range and high resolution, it is a useful tool for the complicated IMRT verification. Furthermore, EPIDose can also evaluate the absolute dose.

Entities:  

Mesh:

Year:  2012        PMID: 23229201     DOI: 10.1007/s12194-012-0192-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device.

Authors:  S C Vieira; M L P Dirkx; K L Pasma; B J M Heijmen
Journal:  Phys Med Biol       Date:  2003-01-21       Impact factor: 3.609

2.  Dosimetric IMRT verification with a flat-panel EPID.

Authors:  B Warkentin; S Steciw; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2003-12       Impact factor: 4.071

3.  Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device.

Authors:  Omar A Zeidan; Jonathan G Li; Manisha Ranade; Anthony M Stell; James F Dempsey
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

4.  [Comparison of dose accuracy between 2D array detectors for pre-treatment IMRT QA].

Authors:  Yuji Nakaguchi; Fujio Araki; Shunji Saiga; Tomohiro Kouno; Masato Maruyama; Kiyotaka Kakei; Nozomu Nagasue; Masahiro Hashida
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2012

5.  Three-dimensional IMRT verification with a flat-panel EPID.

Authors:  S Steciw; B Warkentin; S Rathee; B G Fallone
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

6.  Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems.

Authors:  L Masi; F Casamassima; R Doro; P Francescon
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

7.  Modeling dose distributions from portal dose images using the convolution/superposition method.

Authors:  T R McNutt; T R Mackie; P Reckwerdt; B R Paliwal
Journal:  Med Phys       Date:  1996-08       Impact factor: 4.071

8.  Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm.

Authors:  Sean L Berry; Ren-Dih Sheu; Cynthia S Polvorosa; Cheng-Shie Wuu
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

9.  Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction.

Authors:  Wouter J C van Elmpt; Sebastiaan M J J G Nijsten; André L A J Dekker; Ben J Mijnheer; Philippe Lambin
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

10.  Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams.

Authors:  Peter B Greer; Philip Vial; Lyn Oliver; Clive Baldock
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

View more