Literature DB >> 23214170

High-speed upper-airway imaging using full-range optical coherence tomography.

Joseph Jing1, Jun Zhang, Anthony Chin Loy, Brian J F Wong, Zhongping Chen.   

Abstract

Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizing radiation, and MRI typically requires sedation of the patient to prevent motion artifacts. Long-range optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images with high resolution and without the use of ionizing radiation. In this paper, we present work on the development of a long-range OCT endoscopic probe with 1.2 mm OD and 20 mm working distance used in conjunction with a modified Fourier domain swept source OCT system to acquire structural and anatomical datasets of the human airway. Imaging from the bottom of the larynx to the end of the nasal cavity is completed within 40 s.

Entities:  

Mesh:

Year:  2012        PMID: 23214170      PMCID: PMC3494494          DOI: 10.1117/1.jbo.17.11.110507

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  11 in total

1.  Linear dimensions of the upper airway structure during development: assessment by magnetic resonance imaging.

Authors:  Raanan Arens; Joseph M McDonough; Aaron M Corbin; Mary Elizabeth Hernandez; Greg Maislin; Richard J Schwab; Allan I Pack
Journal:  Am J Respir Crit Care Med       Date:  2002-01-01       Impact factor: 21.405

2.  Imaging true 3D endoscopic anatomy by incorporating magnetic tracking with optical coherence tomography: proof-of-principle for airways.

Authors:  Brandon Lau; Robert A McLaughlin; Andrea Curatolo; Rodney W Kirk; Derek K Gerstmann; David D Sampson
Journal:  Opt Express       Date:  2010-12-20       Impact factor: 3.894

3.  Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator.

Authors:  Jun Zhang; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2005-01-15       Impact factor: 3.776

Review 4.  Adult obstructive sleep apnea: pathophysiology and diagnosis.

Authors:  Susheel P Patil; Hartmut Schneider; Alan R Schwartz; Philip L Smith
Journal:  Chest       Date:  2007-07       Impact factor: 9.410

5.  In vivo size and shape measurement of the human upper airway using endoscopic longrange optical coherence tomography.

Authors:  Julian Armstrong; Matthew Leigh; Ian Walton; Andrei Zvyagin; Sergey Alexandrov; Stefan Schwer; David Sampson; David Hillman; Peter Eastwood
Journal:  Opt Express       Date:  2003-07-28       Impact factor: 3.894

6.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting.

Authors:  S Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-10-04       Impact factor: 3.894

7.  Developmental aspects of the upper airway: report from an NHLBI Workshop, March 5-6, 2009.

Authors:  Carole L Marcus; Richard J H Smith; Leila A Mankarious; Raanan Arens; Gordon S Mitchell; Ravindhra G Elluru; Vito Forte; Steven Goudy; Ethylin W Jabs; Alex A Kane; Eliot Katz; David Paydarfar; Kevin Pereira; Roger H Reeves; Joan T Richtsmeier; Ramon L Ruiz; Bradley T Thach; David E Tunkel; Jeffrey A Whitsett; David Wootton; Carol J Blaisdell
Journal:  Proc Am Thorac Soc       Date:  2009-09-15

8.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

9.  Cephalometric analysis for diagnosis and treatment of obstructive sleep apnea.

Authors:  B deBerry-Borowiecki; A Kukwa; R H Blanks
Journal:  Laryngoscope       Date:  1988-02       Impact factor: 3.325

10.  Age-related changes of the upper airway assessed by 3-dimensional computed tomography.

Authors:  Zachary Abramson; Srinivas Susarla; Maria Troulis; Leonard Kaban
Journal:  J Craniofac Surg       Date:  2009-03       Impact factor: 1.046

View more
  29 in total

1.  Spatiotemporal correlation of optical coherence tomography in-vivo images of rabbit airway for the diagnosis of edema.

Authors:  DongYel Kang; Alex Wang; Veronika Volgger; Zhongping Chen; Brian J F Wong
Journal:  J Biomed Opt       Date:  2015-07       Impact factor: 3.170

2.  Visualizing biofilm formation in endotracheal tubes using endoscopic three-dimensional optical coherence tomography.

Authors:  Andrew E Heidari; Samer Moghaddam; Kimberly K Truong; Kimberly K Troung; Lidek Chou; Carl Genberg; Matthew Brenner; Zhongping Chen
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

3.  Automatic airway wall segmentation and thickness measurement for long-range optical coherence tomography images.

Authors:  Li Qi; Shenghai Huang; Andrew E Heidari; Cuixia Dai; Jiang Zhu; Xuping Zhang; Zhongping Chen
Journal:  Opt Express       Date:  2015-12-28       Impact factor: 3.894

4.  Quantitative Evaluation of Adult Subglottic Stenosis Using Intraoperative Long-range Optical Coherence Tomography.

Authors:  Giriraj K Sharma; Anthony Chin Loy; Erica Su; Joe Jing; Zhongping Chen; Brian J-F Wong; Sunil Verma
Journal:  Ann Otol Rhinol Laryngol       Date:  2016-06-28       Impact factor: 1.547

5.  Ultra-thin and flexible endoscopy probe for optical coherence tomography based on stepwise transitional core fiber.

Authors:  Jangbeom Lee; Yugyeong Chae; Yeh-Chan Ahn; Sucbei Moon
Journal:  Biomed Opt Express       Date:  2015-04-21       Impact factor: 3.732

6.  Airway compliance measured by anatomic optical coherence tomography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Nicusor Iftimia; Hillel Price; Carlton Zdanski; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2017-03-15       Impact factor: 3.732

7.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

8.  Quantitative upper airway endoscopy with swept-source anatomical optical coherence tomography.

Authors:  Kushal Wijesundara; Carlton Zdanski; Julia Kimbell; Hillel Price; Nicusor Iftimia; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2014-02-19       Impact factor: 3.732

9.  Broadband rotary joint for high-speed ultrahigh-resolution endoscopic OCT imaging at 800  nm.

Authors:  Hyeon-Cheol Park; Jessica Mavadia-Shukla; Wu Yuan; Milad Alemohammad; Xingde Li
Journal:  Opt Lett       Date:  2017-12-01       Impact factor: 3.776

Review 10.  The use of magnetic resonance imaging in the evaluation of upper airway structures in paediatric obstructive sleep apnoea syndrome: a systematic review and meta-analysis.

Authors:  Romeo Patini; Mariantonietta Arrica; Enrico Di Stasio; Patrizia Gallenzi; Massimo Cordaro
Journal:  Dentomaxillofac Radiol       Date:  2016-08-19       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.