Broadband rotary joint for high-speed ultrahigh-resolution endoscopic OCT imaging at 800  nm.

Hyeon-Cheol Park, Jessica Mavadia-Shukla, Wu Yuan, Milad Alemohammad, Xingde Li.   

Abstract

We report the development of a broadband rotary joint for high-speed ultrahigh-resolution endoscopic optical coherence tomography (OCT) imaging in the 800 nm spectral range. This rotary joint features a pair of achromatic doublets in order to achieve broadband operation for a 3 dB bandwidth over 150 nm. The measured one-way throughput of the rotary joint is greater than 80%, while the fluctuation of the double-pass coupling efficiency during 360 deg rotation is less than ±5% at a near video-rate speed of 20 revolutions/s (rps). The rotary joint is used in conjunction with a diffractive-optics-based endoscope and 800 nm spectral domain OCT system and achieved an ultrahigh axial resolution of ∼2.4  μm in air. The imaging performance is demonstrated by 3D circumferential imaging of a mouse colon in vivo.

Entities:  

Mesh:

Year:  2017        PMID: 29216160      PMCID: PMC5907933          DOI: 10.1364/OL.42.004978

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  17 in total

1.  Ultrahigh-resolution ophthalmic optical coherence tomography.

Authors:  W Drexler; U Morgner; R K Ghanta; F X Kärtner; J S Schuman; J G Fujimoto
Journal:  Nat Med       Date:  2001-04       Impact factor: 53.440

2.  Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography.

Authors:  P R Herz; Y Chen; A D Aguirre; K Schneider; P Hsiung; J G Fujimoto; K Madden; J Schmitt; J Goodnow; C Petersen
Journal:  Opt Lett       Date:  2004-10-01       Impact factor: 3.776

3.  Imaging needle for optical coherence tomography.

Authors:  X Li; C Chudoba; T Ko; C Pitris; J G Fujimoto
Journal:  Opt Lett       Date:  2000-10-15       Impact factor: 3.776

4.  In vivo size and shape measurement of the human upper airway using endoscopic longrange optical coherence tomography.

Authors:  Julian Armstrong; Matthew Leigh; Ian Walton; Andrei Zvyagin; Sergey Alexandrov; Stefan Schwer; David Sampson; David Hillman; Peter Eastwood
Journal:  Opt Express       Date:  2003-07-28       Impact factor: 3.894

5.  Flexible miniature compound lens design for high-resolution optical coherence tomography balloon imaging catheter.

Authors:  Henry L Fu; Yuxin Leng; Michael J Cobb; Kevin Hsu; Joo Ha Hwang; Xingde Li
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

6.  In vivo endoscopic optical biopsy with optical coherence tomography.

Authors:  G J Tearney; M E Brezinski; B E Bouma; S A Boppart; C Pitris; J F Southern; J G Fujimoto
Journal:  Science       Date:  1997-06-27       Impact factor: 47.728

7.  High frame-rate intravascular optical frequency-domain imaging in vivo.

Authors:  Han Saem Cho; Sun-Joo Jang; Kyunghun Kim; Alexey V Dan-Chin-Yu; Milen Shishkov; Brett E Bouma; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2013-12-16       Impact factor: 3.732

8.  Diffractive catheter for ultrahigh-resolution spectral-domain volumetric OCT imaging.

Authors:  Jiefeng Xi; Anqi Zhang; Zhenyu Liu; Wenxuan Liang; Lih Y Lin; Shaoyong Yu; Xingde Li
Journal:  Opt Lett       Date:  2014-04-01       Impact factor: 3.776

9.  High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography.

Authors:  B E Bouma; G J Tearney; C C Compton; N S Nishioka
Journal:  Gastrointest Endosc       Date:  2000-04       Impact factor: 9.427

10.  Three-dimensional endomicroscopy of the human colon using optical coherence tomography.

Authors:  Desmond C Adler; Chao Zhou; Tsung-Han Tsai; Joe Schmitt; Qin Huang; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Express       Date:  2009-01-19       Impact factor: 3.894

View more
  5 in total

1.  Visualization and Validation of The Microstructures in The Airway Wall in vivo Using Diffractive Optical Coherence Tomography.

Authors:  Jeffrey Thiboutot; Wu Yuan; Hyeon-Cheol Park; Dawei Li; Jeffrey Loube; Wayne Mitzner; Lonny Yarmus; Xingde Li; Robert H Brown
Journal:  Acad Radiol       Date:  2022-03-10       Impact factor: 5.482

2.  In vivo assessment of inflammatory bowel disease in rats with ultrahigh-resolution colonoscopic OCT.

Authors:  Wu Yuan; Yan Feng; Defu Chen; Payam Gharibani; Jiande D Z Chen; Huimin Yu; Xingde Li
Journal:  Biomed Opt Express       Date:  2022-03-15       Impact factor: 3.562

3.  Dual-modality fluorescence lifetime imaging-optical coherence tomography intravascular catheter system with freeform catheter optics.

Authors:  Cai Li; Julien Bec; Xiangnan Zhou; Laura Marcu
Journal:  J Biomed Opt       Date:  2022-07       Impact factor: 3.758

4.  Preliminary human application of optical coherence tomography for quantification and localization of primordial follicles aimed at effective ovarian tissue transplantation.

Authors:  Seido Takae; Kosuke Tsukada; Ichiro Maeda; Naoki Okamoto; Yorino Sato; Haruhiro Kondo; Kiemi Shinya; Yuki Motani; Nao Suzuki
Journal:  J Assist Reprod Genet       Date:  2018-04-02       Impact factor: 3.412

5.  Theranostic OCT microneedle for fast ultrahigh-resolution deep-brain imaging and efficient laser ablation in vivo.

Authors:  Wu Yuan; Defu Chen; Rachel Sarabia-Estrada; Hugo Guerrero-Cázares; Dawei Li; Alfredo Quiñones-Hinojosa; Xingde Li
Journal:  Sci Adv       Date:  2020-04-10       Impact factor: 14.957

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.