Literature DB >> 15675695

Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator.

Jun Zhang1, J Stuart Nelson, Zhongping Chen.   

Abstract

A novel swept-laser-based Fourier-domain optical coherence tomography system using an electro-optic phase modulator was demonstrated. The imaging range was doubled by cancellation of the mirror image. The elimination of low-frequency noises resulting from dc and autocorrelation terms increased the sensitivity by 20 dB.

Mesh:

Year:  2005        PMID: 15675695     DOI: 10.1364/ol.30.000147

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  31 in total

1.  Comparison of phase-shifting techniques for in vivo full-range, high-speed Fourier-domain optical coherence tomography.

Authors:  Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Automatic airway wall segmentation and thickness measurement for long-range optical coherence tomography images.

Authors:  Li Qi; Shenghai Huang; Andrew E Heidari; Cuixia Dai; Jiang Zhu; Xuping Zhang; Zhongping Chen
Journal:  Opt Express       Date:  2015-12-28       Impact factor: 3.894

3.  Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

Authors:  B J Vakoc; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2006-02-01       Impact factor: 3.776

4.  Phase-resolved optical frequency domain imaging.

Authors:  B Vakoc; S Yun; J de Boer; G Tearney; B Bouma
Journal:  Opt Express       Date:  2005-07-11       Impact factor: 3.894

5.  Characterization of Fourier domain mode-locked wavelength swept laser for optical coherence tomography imaging.

Authors:  Min Yong Jeon; Jun Zhang; Zhongping Chen
Journal:  Opt Express       Date:  2008-03-17       Impact factor: 3.894

6.  High-speed and wide bandwidth Fourier domain mode-locked wavelength swept laser with multiple SOAs.

Authors:  Min Yong Jeon; Jun Zhang; Qiang Wang; Zhongping Chen
Journal:  Opt Express       Date:  2008-02-18       Impact factor: 3.894

7.  Detailed visualization of the anterior segment using fourier-domain optical coherence tomography.

Authors:  Sanjay Asrani; Marinko Sarunic; Cecilia Santiago; Joseph Izatt
Journal:  Arch Ophthalmol       Date:  2008-06

8.  Ghost reduction in CP-SSOCT having multiple references using Fourier-domain Shift and Sum.

Authors:  Gyeong Woo Cheon; Peter L Gehlbach; Jin U Kang
Journal:  IEEE Photonics Technol Lett       Date:  2016-06-14       Impact factor: 2.468

9.  Imaging the ocular anterior segment with real-time, full-range Fourier-domain optical coherence tomography.

Authors:  Marinko V Sarunic; Sanjay Asrani; Joseph A Izatt
Journal:  Arch Ophthalmol       Date:  2008-04

10.  Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography.

Authors:  Ehsan Azimi; Bin Liu; Mark E Brezinski
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.