Literature DB >> 28663882

Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Michalina J Gora1,2, Melissa J Suter1,3,4, Guillermo J Tearney1,4,5,6, Xingde Li7,8.   

Abstract

In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed.

Keywords:  (170.1610) Clinical applications; (170.2150) Endoscopic imaging; (170.4500) Optical coherence tomography; (170.4580) Optical diagnostics for medicine

Year:  2017        PMID: 28663882      PMCID: PMC5480489          DOI: 10.1364/BOE.8.002405

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  195 in total

1.  Absorption spectroscopy in tissue-simulating materials: a theoretical and experimental study of photon paths.

Authors:  M S Patterson; S Andersson-Engels; B C Wilson; E K Osei
Journal:  Appl Opt       Date:  1995-01-01       Impact factor: 1.980

2.  Fiber-optic-bundle-based optical coherence tomography.

Authors:  Tuqiang Xie; David Mukai; Shuguang Guo; Matthew Brenner; Zhongping Chen
Journal:  Opt Lett       Date:  2005-07-15       Impact factor: 3.776

3.  Imaging the human vocal folds in vivo with optical coherence tomography: a preliminary experience.

Authors:  Adam M Klein; Mark C Pierce; Steven M Zeitels; R Rox Anderson; James B Kobler; Milen Shishkov; Johannes F de Boer
Journal:  Ann Otol Rhinol Laryngol       Date:  2006-04       Impact factor: 1.547

4.  Comprehensive esophageal microscopy by using optical frequency-domain imaging (with video).

Authors:  Benjamin J Vakoc; Milen Shishko; Seok H Yun; Wang-Yuhl Oh; Melissa J Suter; Adrien E Desjardins; John A Evans; Norman S Nishioka; Guillermo J Tearney; Brett E Bouma
Journal:  Gastrointest Endosc       Date:  2007-03-26       Impact factor: 9.427

5.  Diffuse Optics for Tissue Monitoring and Tomography.

Authors:  T Durduran; R Choe; W B Baker; A G Yodh
Journal:  Rep Prog Phys       Date:  2010-07

6.  Polarization sensitive optical frequency domain imaging system for endobronchial imaging.

Authors:  Jianan Li; Fabio Feroldi; Joop de Lange; Johannes M A Daniels; Katrien Grünberg; Johannes F de Boer
Journal:  Opt Express       Date:  2015-02-09       Impact factor: 3.894

7.  Diagnostic accuracy of conventional and cholangioscopy-guided sampling of indeterminate biliary lesions at the time of ERCP: a prospective, long-term follow-up study.

Authors:  Peter V Draganov; Shailendra Chauhan; Mihir S Wagh; Anand R Gupte; Tong Lin; Wei Hou; Chris E Forsmark
Journal:  Gastrointest Endosc       Date:  2012-02       Impact factor: 9.427

8.  Integrated multimodal endomicroscopy platform for simultaneous en face optical coherence and two-photon fluorescence imaging.

Authors:  Jiefeng Xi; Yongping Chen; Yuying Zhang; Kartikeya Murari; Ming-Jun Li; Xingde Li
Journal:  Opt Lett       Date:  2012-02-01       Impact factor: 3.776

9.  Criteria for pathology recognition in optical coherence tomography of fallopian tubes.

Authors:  Mikhail Kirillin; Olga Panteleeva; Ekaterina Yunusova; Ekaterina Donchenko; Natalia Shakhova
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

10.  Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

Authors:  Tsung-Han Tsai; Benjamin Potsaid; Yuankai K Tao; Vijaysekhar Jayaraman; James Jiang; Peter J S Heim; Martin F Kraus; Chao Zhou; Joachim Hornegger; Hiroshi Mashimo; Alex E Cable; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2013-06-14       Impact factor: 3.732

View more
  60 in total

1.  Localized compliance measurement of the airway wall using anatomic optical coherence elastography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Hillel Price; Carlton Zdanski; Sorin Mitran; Amy L Oldenburg
Journal:  Opt Express       Date:  2019-06-10       Impact factor: 3.894

2.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

3.  Introduction to the feature issue on the 25 year anniversary of optical coherence tomography.

Authors:  Joseph A Izatt; Stephen Boppart; Brett Bouma; Johannes de Boer; Wolfgang Drexler; Xingde Li; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

4.  Integrated optical coherence tomography and multielement ultrasound transducer probe for shear wave elasticity imaging of moving tissues.

Authors:  Andrei B Karpiouk; Donald J VanderLaan; Kirill V Larin; Stanislav Y Emelianov
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

5.  Depth-multiplexed optical coherence tomography dual-beam manually-actuated distortion-corrected imaging (DMDI) with a micromotor catheter.

Authors:  Anthony M D Lee; Calum MacAulay; Pierre Lane
Journal:  Biomed Opt Express       Date:  2018-10-23       Impact factor: 3.732

6.  Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Authors:  Oscar Caravaca Mora; Philippe Zanne; Lucile Zorn; Florent Nageotte; Natalia Zulina; Sara Gravelyn; Paul Montgomery; Michel de Mathelin; Bernard Dallemagne; Michalina J Gora
Journal:  Biomed Opt Express       Date:  2020-02-03       Impact factor: 3.732

7.  Circumferential-scanning endoscopic optical coherence tomography probe based on a circular array of six 2-axis MEMS mirrors.

Authors:  Site Luo; Dan Wang; Jianyu Tang; Liang Zhou; Can Duan; Donglin Wang; Hao Liu; Yu Zhu; Guoxing Li; Hui Zhao; Yuqing Wu; Xin An; Xinling Li; Yabing Liu; Li Huo; Huikai Xie
Journal:  Biomed Opt Express       Date:  2018-04-05       Impact factor: 3.732

8.  A biopsy-needle compatible varifocal multiphoton rigid probe for depth-resolved optical biopsy.

Authors:  Ang Li; Gunnsteinn Hall; Defu Chen; Wenxuan Liang; Bo Ning; Honghua Guan; Xingde Li
Journal:  J Biophotonics       Date:  2018-09-05       Impact factor: 3.207

9.  Computational analysis of six optical coherence tomography systems for vocal fold imaging: A comparison study.

Authors:  Tiffany T Pham; Lily Chen; Andrew E Heidari; Jason J Chen; Alisa Zhukhovitskaya; Yan Li; Urja Patel; Zhongping Chen; Brian J F Wong
Journal:  Lasers Surg Med       Date:  2019-01-25       Impact factor: 4.025

10.  Dimension reduction technique using a multilayered descriptor for high-precision classification of ovarian cancer tissue using optical coherence tomography: a feasibility study.

Authors:  Catherine St-Pierre; Wendy-Julie Madore; Etienne De Montigny; Dominique Trudel; Caroline Boudoux; Nicolas Godbout; Anne-Marie Mes-Masson; Kurosh Rahimi; Frédéric Leblond
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.