Literature DB >> 23213005

Motion and flow insensitive adiabatic T2 -preparation module for cardiac MR imaging at 3 Tesla.

Elizabeth R Jenista1, Wolfgang G Rehwald, Enn-Ling Chen, Han W Kim, Igor Klem, Michele A Parker, Raymond J Kim.   

Abstract

A versatile method for generating T2 -weighting is a T2 -preparation module, which has been used successfully for cardiac imaging at 1.5T. Although it has been applied at 3T, higher fields (B0 ≥ 3T) can degrade B0 and B1 homogeneity and result in nonuniform magnetization preparation. For cardiac imaging, blood flow and cardiac motion may further impair magnetization preparation. In this study, a novel T2 -preparation module containing multiple adiabatic B1 -insensitive refocusing pulses is introduced and compared with three previously described modules [(a) composite MLEV4, (b) modified BIR-4 (mBIR-4), and (c) Silver-Hoult-pair]. In the static phantom, the proposed module provided similar or better B0 and B1 insensitivity than the other modules. In human subjects (n = 21), quantitative measurement of image signal coefficient of variation, reflecting overall image inhomogeneity, was lower for the proposed module (0.10) than for MLEV4 (0.15, P < 0.0001), mBIR-4 (0.27, P < 0.0001), and Silver-Hoult-pair (0.14, P = 0.001) modules. Similarly, qualitative analysis revealed that the proposed module had the best image quality scores and ranking (both, P < 0.0001). In conclusion, we present a new T2 -preparation module, which is shown to be robust for cardiac imaging at 3T in comparison with existing methods.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  3T; T2-weighting; adiabatic pulses; cardiac imaging

Mesh:

Year:  2012        PMID: 23213005      PMCID: PMC3926429          DOI: 10.1002/mrm.24564

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Flow-independent magnetic resonance projection angiography.

Authors:  G A Wright; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

2.  Comprehensive cardiac magnetic resonance imaging at 3.0 Tesla: feasibility and implications for clinical applications.

Authors:  Matthias Gutberlet; Ralph Noeske; Kerstin Schwinge; Patrick Freyhardt; Roland Felix; Thoralf Niendorf
Journal:  Invest Radiol       Date:  2006-02       Impact factor: 6.016

Review 3.  Cardiac MRI of ischemic heart disease at 3 T: potential and challenges.

Authors:  Oliver Wieben; Christopher Francois; Scott B Reeder
Journal:  Eur J Radiol       Date:  2008-01       Impact factor: 3.528

4.  Coronary angiography with magnetization-prepared T2 contrast.

Authors:  J H Brittain; B S Hu; G A Wright; C H Meyer; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

5.  Broadband and adiabatic inversion of a two-level system by phase-modulated pulses.

Authors: 
Journal:  Phys Rev A Gen Phys       Date:  1985-12

6.  Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction.

Authors:  Jingsi Xie; Peng Lai; Himanshu Bhat; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

7.  An MRI phantom material for quantitative relaxometry.

Authors:  K A Kraft; P P Fatouros; G D Clarke; P R Kishore
Journal:  Magn Reson Med       Date:  1987-12       Impact factor: 4.668

8.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

9.  Use of 2D sensitivity encoding for slow-infusion contrast-enhanced isotropic 3-T whole-heart coronary MR angiography.

Authors:  Jing Yu; Ingo Paetsch; Bernhard Schnackenburg; Eckart Fleck; Robert G Weiss; Matthias Stuber; Cosima Jahnke
Journal:  AJR Am J Roentgenol       Date:  2011-08       Impact factor: 3.959

10.  T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

Authors:  Peter Kellman; Anthony H Aletras; Christine Mancini; Elliot R McVeigh; Andrew E Arai
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

View more
  18 in total

1.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

2.  Improved Brachial Plexus Visualization Using an Adiabatic iMSDE-Prepared STIR 3D TSE.

Authors:  Elisabeth Klupp; Barbara Cervantes; Nico Sollmann; Franziska Treibel; Dominik Weidlich; Thomas Baum; Ernst J Rummeny; Claus Zimmer; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Clin Neuroradiol       Date:  2018-07-23       Impact factor: 3.649

3.  Combined T2 -preparation and multidimensional outer volume suppression for coronary artery imaging with 3D cones trajectories.

Authors:  David Y Zeng; Corey A Baron; Mario O Malavé; Adam B Kerr; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2019-11-05       Impact factor: 4.668

4.  Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory.

Authors:  Hsin-Jung Yang; Behzad Sharif; Jianing Pang; Avinash Kali; Xiaoming Bi; Ivan Cokic; Debiao Li; Rohan Dharmakumar
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

5.  Shuffled magnetization-prepared multicontrast rapid gradient-echo imaging.

Authors:  Peng Cao; Xucheng Zhu; Shuyu Tang; Andrew Leynes; Angela Jakary; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2017-10-27       Impact factor: 4.668

6.  In vivo diffusion-tensor MRI of the human heart on a 3 tesla clinical scanner: An optimized second order (M2) motion compensated diffusion-preparation approach.

Authors:  Christopher Nguyen; Zhaoyang Fan; Yibin Xie; Jianing Pang; Peter Speier; Xiaoming Bi; Jon Kobashigawa; Debiao Li
Journal:  Magn Reson Med       Date:  2016-08-23       Impact factor: 4.668

7.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

8.  Feasibility and reproducibility of whole brain myelin water mapping in 4 minutes using fast acquisition with spiral trajectory and adiabatic T2prep (FAST-T2) at 3T.

Authors:  Thanh D Nguyen; Kofi Deh; Elizabeth Monohan; Sneha Pandya; Pascal Spincemaille; Ashish Raj; Yi Wang; Susan A Gauthier
Journal:  Magn Reson Med       Date:  2015-08-29       Impact factor: 4.668

9.  Profilometry: A new statistical framework for the characterization of white matter pathways, with application to multiple sclerosis.

Authors:  Michael Dayan; Elizabeth Monohan; Sneha Pandya; Amy Kuceyeski; Thanh D Nguyen; Ashish Raj; Susan A Gauthier
Journal:  Hum Brain Mapp       Date:  2015-12-15       Impact factor: 5.038

10.  MRI Analysis of White Matter Myelin Water Content in Multiple Sclerosis: A Novel Approach Applied to Finding Correlates of Cortical Thinning.

Authors:  Michael Dayan; Sandra M Hurtado Rúa; Elizabeth Monohan; Kyoko Fujimoto; Sneha Pandya; Eve M LoCastro; Tim Vartanian; Thanh D Nguyen; Ashish Raj; Susan A Gauthier
Journal:  Front Neurosci       Date:  2017-05-26       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.