OBJECTIVES: We sought to determine the relaxivity and accurate relaxation rates of Gd-DTPA, Gd-BT-DO3A, and Gd-BOPTA at 0.2, 1.5, and 3 T in human blood plasma. MATERIALS AND METHODS: Contrast media concentrations between 0.01 and 16 mM in human plasma were used for relaxation measurements. The R1 and R2 relaxation rates and r1 and r2 relaxivities were determined. RESULTS: Gd-BOPTA produced the highest relaxation rates and relaxivities at all field strengths. The r1 and r2 values for Gd-BOPTA were 107-131% and 91-244% higher than for Gd-DTPA, respectively, and 72-98% and 82-166% higher than for Gd-BT-DO3A. Higher field strengths resulted in lower values of R1, R2, and r1 for all contrast agents tested and of r2 for Gd-DTPA and Gd-BT-DO3A. A linear dependence of R1 and R2 on concentration was found for Gd-DTPA and Gd-BT-DO3A and a nonlinear dependence for Gd-BOPTA for concentrations larger than 1 mM. The r1 and r2 relaxivity of Gd-BOPTA increased with decreasing concentration. CONCLUSIONS: Gd-BOPTA demonstrates the highest longitudinal r1 at all field strengths, which is ascribable to weak protein interaction. The R2/R1 ratio increases at higher field strength only for Gd-BOPTA, hence very short echo times are required for Gd-BOPTA to benefit from the higher longitudinal relaxivity.
OBJECTIVES: We sought to determine the relaxivity and accurate relaxation rates of Gd-DTPA, Gd-BT-DO3A, and Gd-BOPTA at 0.2, 1.5, and 3 T in human blood plasma. MATERIALS AND METHODS: Contrast media concentrations between 0.01 and 16 mM in human plasma were used for relaxation measurements. The R1 and R2 relaxation rates and r1 and r2 relaxivities were determined. RESULTS:Gd-BOPTA produced the highest relaxation rates and relaxivities at all field strengths. The r1 and r2 values for Gd-BOPTA were 107-131% and 91-244% higher than for Gd-DTPA, respectively, and 72-98% and 82-166% higher than for Gd-BT-DO3A. Higher field strengths resulted in lower values of R1, R2, and r1 for all contrast agents tested and of r2 for Gd-DTPA and Gd-BT-DO3A. A linear dependence of R1 and R2 on concentration was found for Gd-DTPA and Gd-BT-DO3A and a nonlinear dependence for Gd-BOPTA for concentrations larger than 1 mM. The r1 and r2 relaxivity of Gd-BOPTA increased with decreasing concentration. CONCLUSIONS:Gd-BOPTA demonstrates the highest longitudinal r1 at all field strengths, which is ascribable to weak protein interaction. The R2/R1 ratio increases at higher field strength only for Gd-BOPTA, hence very short echo times are required for Gd-BOPTA to benefit from the higher longitudinal relaxivity.
Authors: Jan Thorsten Winterer; Olaf Moske-Eick; Michael Markl; Alexander Frydrychowicz; Thorsten Alexander Bley; Mathias Langer Journal: Eur Radiol Date: 2007-11-27 Impact factor: 5.315
Authors: A C Schmitz; N H G M Peters; W B Veldhuis; A M Fernandez Gallardo; P J van Diest; G Stapper; R van Hillegersberg; W P Th M Mali; M A A J van den Bosch Journal: Eur Radiol Date: 2007-09-20 Impact factor: 5.315
Authors: Bernhard D Klumpp; Joern Sandstede; Klaus P Lodemann; Achim Seeger; Tobias Hoevelborn; Michael Fenchel; Ulrich Kramer; Claus D Claussen; Stephan Miller Journal: Eur Radiol Date: 2008-12-18 Impact factor: 5.315
Authors: Eric M Bultman; Ethan K Brodsky; Debra E Horng; Pablo Irarrazaval; William R Schelman; Walter F Block; Scott B Reeder Journal: J Magn Reson Imaging Date: 2013-11-04 Impact factor: 4.813
Authors: Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A Omary; Andrew C Larson Journal: Magn Reson Med Date: 2008-10 Impact factor: 4.668
Authors: Chunying Shu; Frank D Corwin; Jianfei Zhang; Zhijian Chen; Jonathan E Reid; Minghao Sun; Wei Xu; Jae Hyun Sim; Chunru Wang; Panos P Fatouros; Alan R Esker; Harry W Gibson; Harry C Dorn Journal: Bioconjug Chem Date: 2009-06 Impact factor: 4.774