Literature DB >> 15955853

Carotid artery stenosis: intraindividual correlations of 3D time-of-flight MR angiography, contrast-enhanced MR angiography, conventional DSA, and rotational angiography for detection and grading.

Nicoletta Anzalone1, Francesco Scomazzoni, Renata Castellano, Laura Strada, Claudio Righi, Letterio S Politi, Miles A Kirchin, Roberto Chiesa, Giuseppe Scotti.   

Abstract

PURPOSE: To compare three-dimensional (3D) time-of-flight (TOF) MR angiography, contrast-enhanced MR angiography, digital subtraction angiography (DSA), and rotational angiography for depiction of stenosis.
MATERIALS AND METHODS: The study had Ethics Committee approval, and each patient gave written informed consent. Forty-nine patients (18 women, mean age, 67.2 years +/- 9.1 [+/- standard deviation], and 31 men, mean age, 63.1 years +/- 8.0) with symptomatic stenosis of internal carotid artery (ICA) diagnosed at duplex ultrasonography underwent transverse 3D TOF MR angiography with sliding interleaved kY acquisition and coronal contrast-enhanced MR angiography, followed by DSA and rotational angiography within 48 hours. MR angiography was performed at 1.5-T with a cervical coil. Contrast-enhanced MR angiograms were obtained after a bolus injection of 20 mL of gadobenate dimeglumine. Maximum ICA stenosis on maximum intensity projection and source images was quantified according to NASCET criteria. Correlations for 3D TOF MR angiography, contrast-enhanced MR angiography, DSA, and rotational angiography were determined by means of cross tabulation, and accuracy for detection and grading of stenoses were calculated. Data were evaluated with analysis of variance, Wilcoxon signed rank test, and McNemar test, all at significance of P < .05.
RESULTS: Ninety-eight ICAs were evaluated at contrast-enhanced MR angiography, DSA, and rotational angiography, and 97 were evaluated at 3D TOF MR angiography. Correlations for contrast-enhanced MR angiography, 3D TOF MR angiography, and DSA relative to rotational angiography were r2 = 0.9332, r2 = 0.9048, and r2 = 0.9255, respectively. Lower correlation (r2 = 0.8593) was noted for contrast-enhanced MR angiography and DSA. Respective sensitivity and specificity for detection of hemodynamically relevant stenosis relative to rotational angiography were 100% and 90% for contrast-enhanced MR angiography, 95.5% and 87.2% for 3D TOF MR angiography, and 88.6% and 100% for DSA. Four of 31 severe stenoses were underestimated at DSA, and three were underestimated at contrast-enhanced MR angiography. Three severe stenoses were underestimated at 3D TOF MR angiography, and one was misclassified as occluded. Of 13 moderate (50%-69%) stenoses, one was overestimated at contrast-enhanced MR angiography, two were underestimated and three overestimated at 3D TOF MR angiography, and two were underestimated at DSA.
CONCLUSION: DSA results in an underestimation of ICA stenosis compared with rotational angiography. Contrast-enhanced MR angiography correlates best with rotational angiography. Copyright RSNA, 2005

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15955853     DOI: 10.1148/radiol.2361032048

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  29 in total

1.  [CT diagnostics of carotid artery stenosis].

Authors:  W Reith; C Roth
Journal:  Radiologe       Date:  2010-07       Impact factor: 0.635

2.  Multimodality Imaging of Carotid Stenosis.

Authors:  Theodor Adla; Radka Adlova
Journal:  Int J Angiol       Date:  2015-07-15

Review 3.  Cross-sectional vascular imaging with CT and MR angiography.

Authors:  Hasan K Kabul; Klaus D Hagspiel
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

4.  Angiography underestimates peripheral atherosclerosis: lumenography revisited.

Authors:  Vikram S Kashyap; Mircea L Pavkov; Paul D Bishop; Sean P Nassoiy; Matthew J Eagleton; Daniel G Clair; Kenneth Ouriel
Journal:  J Endovasc Ther       Date:  2008-02       Impact factor: 3.487

5.  MR angiography at 3 Tesla to assess proximal internal carotid artery stenoses: contrast-enhanced or 3D time-of-flight MR angiography?

Authors:  J Weber; P Veith; B Jung; G Ihorst; O Moske-Eick; S Meckel; H Urbach; C A Taschner
Journal:  Clin Neuroradiol       Date:  2014-01-03       Impact factor: 3.649

6.  Diagnostic accuracy of colour Doppler ultrasonography, CT angiography and blood-pool-enhanced MR angiography in assessing carotid stenosis: a comparative study with DSA in 170 patients.

Authors:  M Anzidei; A Napoli; F Zaccagna; P Di Paolo; L Saba; B Cavallo Marincola; C Zini; G Cartocci; L Di Mare; C Catalano; R Passariello
Journal:  Radiol Med       Date:  2011-03-07       Impact factor: 3.469

7.  Magnetic resonance angiography of the carotid arteries: comparison of unenhanced and contrast enhanced techniques.

Authors:  Harald Kramer; Val M Runge; John N Morelli; Kenneth D Williams; L Gill Naul; Konstantin Nikolaou; Maximilian F Reiser; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2011-04-09       Impact factor: 5.315

8.  Preliminary experience with MRA in evaluating the degree of carotid stenosis and plaque morphology using high-resolution sequences after gadofosveset trisodium (Vasovist) administration: comparison with CTA and DSA.

Authors:  M Anzidei; A Napoli; D Geiger; B Cavallo Marincola; C Zini; F Zaccagna; P Di Paolo; C Catalano; R Passariello
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

9.  Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

Authors:  A Le Bras; H Raoult; J-C Ferré; T Ronzière; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

10.  Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques.

Authors:  Jan Menke
Journal:  Eur Radiol       Date:  2009-04-28       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.