The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric multifocal IOL. At 6 months after surgery, postoperative spherical equivalent was within ±1.00 D in 96.8% of eyes, with 94.7% of patients presenting a postoperative binocular far LogMAR uncorrected visual acuity (UCVA) of 0.1 or better. Far best-corrected distance VA improved significantly (p < 0.01), with postoperative values of 0.1 or better in 96.8% of eyes. Postoperative near UCVA was 0.10 (equivalent to J1) or better in 93.55% of eyes. Furthermore, the IOL power was found to be very poorly correlated with the postoperative far LogMAR (r = 0.13) and near UCVA (r = 0.13). In conclusion, the aspheric diffractive multifocal IOL Tecnis ZMB00 provides a restoration of the far and near visual function after phacoemulsification surgery for cataract removal or presbyopia correction, which is predictable and independent from the optical power of the implanted IOL.Entities:
Keywords: Diffractive intraocular lens; Multifocal intraocular lens; Spherical aberration; Tecnis
Year: 2012 PMID: 23185180 PMCID: PMC3506050 DOI: 10.1159/000343919
Source DB: PubMed Journal: Case Rep Ophthalmol ISSN: 1663-2699
Fig. 1Distribution of far and near UCVA. a Monocular. b Binocular.
Fig. 3Scattergram showing the relationship between the optical power of the IOL implanted and different visual variables. a Postoperative far LogMAR UCVA. b Postoperative near LogMAR UCVA. c Postoperative far LogMAR BCVA.
Summary of the far and near visual and refractive outcomes in our study with the Tecnis ZMB00
| Before surgery | –6 Months after surgery | p value | |
|---|---|---|---|
| Monocular far LogMAR UCVA | – | 0.08±0.11 (0.00 to 0.40) | – |
| Binocular far LogMAR UCVA | – | 0.01±0.08 (−0.08 to 0.22) | – |
| Manifest sphere, D | +0.27±2.88 (–7.00 to +4.50) | +0.34±0.64 (−0.75 to +2.25) | 0.91 |
| Manifest cylinder, D | −0.60±0.71 (–3.50 to 0.00) | −0.57±0.38 (–1.50 to 0.00) | 0.82 |
| Spherical equivalent, D | −0.03±2.84 (–7.13 to +4.38) | +0.05±0.55 (–1.00 to +1.63) | 0.88 |
| Far LogMAR BCVA | −0.41±0.32 (0.05 to 1.52) | 0.03±0.05 (0.00 to 0.15) | <0.01 |
| Monocular near LogMAR UCVA | – | 0.03±0.09 (−0.10 to 0.30) | – |
| Binocular near LogMAR UCVA | – | 0.00±0.08 (−0.10 to 0.10) | – |