| Literature DB >> 21499564 |
Priyanka Sood1, Maria A Woodward.
Abstract
Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis(®) Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractive multifocal lens design. The design aims to minimize spherical aberration and improve range of focus. The purpose of this review is to assess patient acceptability of the Tecnis(®) multifocal intraocular lens.Entities:
Keywords: Tecnis®; intraocular lens; multifocal; presbyopia
Year: 2011 PMID: 21499564 PMCID: PMC3076114 DOI: 10.2147/OPTH.S11126
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Summary of Tecnis® multifocal studies
| Goes | 2008 | Prospective case series | Tecnis® ZM900 | 59 eyes of 30 patients | 6 months | Examined distance, intermediate, and near vision after refractive lens exchange. Assessed overall satisfaction, photic phenomena, difficulty driving at night and spectacle independence. |
| Bautista et al | 2009 | Prospective case series | Tecnis® ZM900 | 250 eyes of 137 patients | 5 to 7 months | Examined near vision, distance corrected near vision, uncorrected vision, best corrected vision. Assessed patient satisfaction, posterior capsule opacification and contrast sensitivity under photopic conditions. |
| Hutz et al | 2006 | Prospective, randomized study | Tecnis® ZM900 vs Array® SA40N vs SA60D3 | 120 eyes of 60 patients | 6 weeks | Assessed reading ability (uncorrected, best distance corrected and best near corrected) under low and bright light. |
| Akaishi et al | 2010 | Retrospective review | Tecnis® ZM900 | 2500 eyes of 1558 patients | 3 months to 3 years | Examined distance and near vision (uncorrected and corrected). Assessed overall satisfaction, spectacle independence, and photic phenomena. |
| Hutz et al | 2008 | Retrospective study | Tecnis® ZM900 vs Array® SA40N vs SA60D3 | 60 eyes of 30 patients | 12 months | Assessed intermediate vision (uncorrected and distance corrected) and reading speed under low and bright light. |
| Kaymak et al | 2008 | Prospective non-randomized intra-individual comparative study | Tecnis® ZM900 vs ReSTOR® | 32 eyes of 16 patients | 6 months | Examined distance visual acuity, contrast sensitivity and near visual acuity under different contrast levels. |
| Cillino et al | 2008 | Randomized prospective study | Tecnis® ZM900 vs AR40 vs Array® SA40N vs ReZoom® | 124 eyes of 62 patients | 12 months | Examined uncorrected and corrected distance, near, and intermediate visual acuity. Assessed defocusing curves, contrast sensitivity, and surveyed quality of life. |
| Palmer et al | 2008 | Prospective, randomized control study | Tecnis® Z9000 vs Tecnis® ZM900 vs ReZoom® vs TwinSet® | 228 eyes of 114 patients | 3 months | Examined binocular and monocular distance and near visual acuity (uncorrected and best corrected). Assessed contrast sensitivity, spectacle dependence, photic phenomena. |
| Mester et al | 2007 | Prospective comparative study | Tecnis® ZM900 vs Array® SA40 | 100 eyes of 50 patients | 4 to 5 months | Assessed distance and near visual acuity (uncorrected and corrected) at different contrast levels. Assessed contrast sensitivity at different spatial frequencies, pupil size and refraction. |
| Packer et al | 2009 | Nonrandomized, multicenter, comparative study | Tecnis® ZM900 vs CeeOn® 911A | 489 eyes of 248 patients | 12 months | Examined distance and near visual acuity (uncorrected and corrected). Assessed depth of focus, contrast sensitivity, reading speed, occurrence of photic phenomena, and spectacle independence. |
| Ngo et al | 2010 | Retrospective study | Tecnis® ZM900 vs ReSTOR® SA60D3 vs ReSTOR® SN60D3 | 108 eyes of 54 patients | 3 months | Assessed uncorrected and best corrected distance visual acuity as well as uncorrected and distance corrected near visual acuity. |
| Gierek-Ciaciura et al | 2009 | Prospective, nonrandomized, comparative study | Tecnis® ZM900 vs ReZoom® NXG1 vs ReSTOR® SA60D3 | 60 eyes of 30 patients | 6 months | Examined distance and near visual acuity (uncorrected and corrected). Assessed spectacle independence, photic phenomena, patient determination of quality of vision, and contrast sensitivity. |