Literature DB >> 22464368

Comparison of through-focus image sharpness across five presbyopia-correcting intraocular lenses.

Jay S Pepose1, Daozhi Wang, Griffith E Altmann.   

Abstract

PURPOSE: To assess through-focus polychromatic image sharpness of 5 FDA-approved presbyopia-correcting intraocular lenses (IOLs) through a range of object vergences and pupil diameters using an image sharpness algorithm.
DESIGN: Laboratory investigation.
METHODS: A 1951 USAF resolution target was imaged through Crystalens AO (AO), Crystalens HD (HD), aspheric ReSTOR +4 (R4), aspheric ReSTOR +3 (R3), and Tecnis Multifocal Acrylic (TMF) IOL in a model eye and captured digitally for each combination of pupil diameter and object vergence. The sharpness of each digital image was objectively scored using a 2-dimensional gradient function.
RESULTS: AO had the best distance image sharpness for all pupil diameters and was superior to the HD. With a 5-mm pupil, the R4 distance image sharpness was similar to the HD and at 6 mm the TMF was superior to the HD, R3, and R4. The R3 moved the near focal point farther from the patient compared to the R4, but did not improve image sharpness at intermediate distances and showed worse distance and near image sharpness. Consistent with apodization, the ReSTOR IOLs displayed better distance and poorer near image sharpness as pupil diameter increased. TMF showed consistent distance and near image sharpness across pupil diameters and the best near image sharpness for all pupil diameters.
CONCLUSIONS: Differing IOL design strategies to increase depth of field are associated with quantifiable differences in image sharpness at varying vergences and pupil sizes. Objective comparison of the imaging properties of specific presbyopia-correcting IOLs in relation to patient's pupil sizes can be useful in selecting the most appropriate IOL for each patient.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22464368     DOI: 10.1016/j.ajo.2012.01.013

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  9 in total

Review 1.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

2.  Presbyopia-Correcting Intraocular Lenses Implantation in Eyes After Corneal Refractive Laser Surgery: A Meta-Analysis and Systematic Review.

Authors:  Yang Sun; Yingying Hong; Xianfang Rong; Yinghong Ji
Journal:  Front Med (Lausanne)       Date:  2022-04-11

3.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

4.  Visual Outcomes, Quality of Vision, and Quality of Life of Diffractive Multifocal Intraocular Lens Implantation after Myopic Laser In Situ Keratomileusis: A Prospective, Observational Case Series.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

5.  Fractal-structured multifocal intraocular lens.

Authors:  Laura Remón; Salvador García-Delpech; Patricia Udaondo; Vicente Ferrando; Juan A Monsoriu; Walter D Furlan
Journal:  PLoS One       Date:  2018-07-09       Impact factor: 3.240

6.  Comparison of three different diffractıve multifocal intraocular lenses with a +2.5, +3.0, and +3.75 diopter additıon power.

Authors:  Emre Altinkurt; Orkun Muftuoglu
Journal:  Saudi J Ophthalmol       Date:  2019-11-06

7.  Intraocular lens multifocality combined with the compensation for corneal spherical aberration: a new concept of presbyopia-correcting intraocular lens.

Authors:  Reiner Friedrich
Journal:  Case Rep Ophthalmol       Date:  2012-10-24

8.  Prospective evaluation of visual outcomes with three presbyopia-correcting intraocular lenses following cataract surgery.

Authors:  Re Ang; Ga Martinez; Em Cruz; Aa Tiongson; Ag Dela Cruz
Journal:  Clin Ophthalmol       Date:  2013-09-17

9.  Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens.

Authors:  Jan Willem van der Linden; Ivanka J van der Meulen; Maarten P Mourits; Ruth Lapid-Gortzak
Journal:  Int Ophthalmol       Date:  2013-02-05       Impact factor: 2.031

  9 in total