Literature DB >> 23179751

Application of a new three-dimensional method for the measurement of coronary stent angulation and comparison with conventional methods.

Huaiyu Qiao1, Luyue Gai, Minhan Wang, Bin He, Shuoyang Zhang, Xia Yang, Qinhua Jin, Zhiwei Guan.   

Abstract

The precision of the measurement of the angulation of coronary stents or lesions using coronary angiography (CA) and computed tomographic angiography (CTA) has not been established, and obtaining a rotating artery tree to measure angulation based on CTA is time-consuming. The aim of this study was to evaluate the utility of a new three-dimensional centerline method that we have developed for the measurement of coronary stent angulation based on CTA and to compare it with other conventional methods. We used the centerline method compacted by means of our new software, the conventional artery rotation method based on CTA and the simple CA method to measure the angulations of phantoms in vitro and stents implanted in patients. The precision and repetition of this new method was compared with those of the other two methods. The angulation values obtained from both the centerline and artery rotation methods based on CTA had high correlation and agreement with the true angulation values measured using a phantom; the 95 % confidence intervals (CIs) for the differences were -0.67° to 0.91° and -0.59° to 2.93°, respectively, while the difference between the value determined using the CA method and the true angulation of the phantoms ranged from 3° to 21.8° (median 8.1°). In clinical coronary stent measurement, the difference between artery rotation and centerline measurement was small (95 % CI -9.0° to 7.6°), and both methods had good repeatability. The time required to complete the measurement was considerably shorter (p < 0.001) using the centerline method than artery rotation method (12.5 ± 1.86 vs. 71.8 ± 13.6 s), while the CA method had poor precision and repeatability in the measurement of clinical stent angulation relative to the methods based on CTA (95 % CI -14.7° to 21.7°). Our three-dimensional centerline method based on CTA for the measurement of angulation was reliable and easy to implement in both clinical and basic research image analysis, and the centerline and conventional artery rotation methods can be used interchangeably. In addition, the value obtained for the coronary stent angulation using the CA method had a large bias.

Entities:  

Mesh:

Year:  2012        PMID: 23179751     DOI: 10.1007/s10554-012-0157-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

Review 1.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

2.  Comparison of plaque prolapse in consecutive patients treated with Xience V and Taxus Liberte stents.

Authors:  Zhu Jun Shen; Salvatore Brugaletta; Hector M Garcia-Garcia; Jurgen Ligthart; Josep Gomez-Lara; Roberto Diletti; Giovanna Sarno; Karen Witberg; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2010-12-21       Impact factor: 2.357

3.  Three-dimensional analysis of vulnerable segments in the left anterior descending artery.

Authors:  Demosthenes G Katritsis; Ioannis Pantos; Socrates Korovesis; Marios Hadjipavlou; Efthalia Tzanalaridou; Timothy Lockie; Simon Redwood; Eutychios Voridis; Efstathios P Efstathopoulos
Journal:  Coron Artery Dis       Date:  2009-05       Impact factor: 1.439

4.  Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation.

Authors:  Yasushi Ino; Yasuaki Toyoda; Atsushi Tanaka; Shuuta Ishii; Yoshio Kusuyama; Takashi Kubo; Shigeho Takarada; Hironori Kitabata; Takashi Tanimoto; Masato Mizukoshi; Toshio Imanishi; Takashi Akasaka
Journal:  Circ J       Date:  2009-08-28       Impact factor: 2.993

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Flat panel digital detector cinefluoroscopy late following SES or BMS implantation for detection of coronary stent fracture in asymptomatic patients.

Authors:  Periklis A Davlouros; Corina Chefneux; Ioanna Xanthopoulou; Maria Papathanasiou; Evaggelia Zaharioglou; Grigorios Tsigkas; Dimitrios Alexopoulos
Journal:  Int J Cardiol       Date:  2010-12-03       Impact factor: 4.164

7.  Coronary and systemic stent embolization during percutaneous coronary interventions: a single center experience.

Authors:  A Yucel Colkesen; Mehmet Baltali; Tayfun Acil; Goknur Tekin; Abdullah Tekin; Tansel Erol; Alpay T Sezgin; Haldun Muderrisoglu
Journal:  Int Heart J       Date:  2007-03       Impact factor: 1.862

8.  Anatomic assessment of the bifurcation of the left main coronary artery using multidetector computed tomography.

Authors:  Kevin N Christensen; Scott R Harris; Adam T Froemming; Waleed Brinjikji; Philip Araoz; Samuel J Asirvatham; Nirusha Lachman
Journal:  Surg Radiol Anat       Date:  2010-02-27       Impact factor: 1.246

9.  Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation.

Authors:  Hisashi Umeda; Tomoko Gochi; Mitsunori Iwase; Hideo Izawa; Takeshi Shimizu; Ryoji Ishiki; Haruo Inagaki; Junji Toyama; Mitsuhiro Yokota; Toyoaki Murohara
Journal:  Int J Cardiol       Date:  2008-03-14       Impact factor: 4.164

10.  A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation.

Authors:  Jeffrey J Popma; Klaus Tiroch; Alexandra Almonacid; Sidney Cohen; David E Kandzari; Martin B Leon
Journal:  Am J Cardiol       Date:  2009-04-01       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.