Literature DB >> 23179322

[Non-fluoroscopic catheter tracking: the MediGuide™ system].

Philipp Sommer1, S Rolf, S Richter, G Hindricks, C Piorkowski.   

Abstract

Conventional fluoroscopy is the main technology for intracardiac device tracking in interventional cardiovascular procedures. For therapy delivery it carries the advantage of being able to instantaneously localize the device and its spatial relationship with respect to the moving target organ. However, besides the associated X-ray exposure, fluoroscopy only provides 2D orientation. For treatment of complex cardiac anatomies and substrates such as in interventional electrophysiology, 3-D mapping technologies have been introduced to facilitate spatial, anatomic, and electrical orientation. A new technological platform (MediGuide(™)) offers the option to continuously display the catheter tip on a prerecorded cine-loop allowing better anatomic understanding of the underlying substrate. We describe our initial experience using the system with diagnostic catheters only and the first procedures with the MediGuide(™) equipped ablation catheter (available since May 2012). We could show a significant decrease of fluoroscopy time in all types of procedures with comparable procedure times. No increase in complication rates was observed.

Entities:  

Mesh:

Year:  2012        PMID: 23179322     DOI: 10.1007/s00399-012-0236-4

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  13 in total

1.  Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

Authors:  Sascha Rolf; Philipp Sommer; Thomas Gaspar; Silke John; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-07-07

Review 2.  Medical positioning system: a technical report.

Authors:  Moshe Y Flugelman; Avinoam Shiran; Danielle Nusimovici-Avadis; Liat Schwartz; Adrian Herscovici; Amit Cohen; Rona Shofti; Basil S Lewis; Andreas Luchner; Andreas Jeron
Journal:  EuroIntervention       Date:  2008-05       Impact factor: 6.534

3.  Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.

Authors:  Christopher Piorkowski; Gerhard Hindricks
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-08

4.  Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX).

Authors:  Heidi Luise Estner; Isabel Deisenhofer; Armin Luik; Gjin Ndrepepa; Christian von Bary; Bernhard Zrenner; Claus Schmitt
Journal:  Europace       Date:  2006-07-10       Impact factor: 5.214

5.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

6.  First-in-man (FIM) experience with the Magnetic Medical Positioning System (MPS) for intracoronary navigation.

Authors:  Andreas Jeron; Sabine Fredersdorf; Kurt Debl; Eitan Oren; Alon Izmirli; Alexander Peleg; Anton Nekovar; Adrian Herscovici; Günter A Riegger; Andreas Luchner
Journal:  EuroIntervention       Date:  2009-11       Impact factor: 6.534

Review 7.  Potential biological effects following high X-ray dose interventional procedures.

Authors:  L K Wagner; P J Eifel; R A Geise
Journal:  J Vasc Interv Radiol       Date:  1994 Jan-Feb       Impact factor: 3.464

8.  A new nonfluoroscopic navigation system to guide pulmonary vein isolation.

Authors:  Claudio Tondo; Massimo Mantica; Giovanni Russo; Eleni Karapatsoudi; Arianna Lucchina; Franco Nigro; Michaela Wild; Cristina Molinaro; Roberto Bavila
Journal:  Pacing Clin Electrophysiol       Date:  2005-01       Impact factor: 1.976

9.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

10.  Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system.

Authors:  Martin Rotter; Yoshihide Takahashi; Prashanthan Sanders; Michel Haïssaguerre; Pierre Jaïs; Li-Fern Hsu; Fréderic Sacher; Jean-Luc Pasquié; Jacques Clementy; Mélèze Hocini
Journal:  Eur Heart J       Date:  2005-03-01       Impact factor: 29.983

View more
  3 in total

1.  Impact of nonfluoroscopic MediGuide™ tracking system on radiation exposure in radiofrequency ablation procedures (LESS-RADS registry)-an initial experience.

Authors:  Ajay Vallakati; Yeruva Madhu Reddy; Martin Emert; Pramod Janga; Moussa C Mansour; E Kevin Heist; Rhea Pimentel; Raghuveer Dendi; Donita Atkins; Sudharani Bommana; Srijoy Mahapatra; Michael Heard; Jeremy Ruskin; Loren Berenbom; Buddhadeb Dawn; Dhanunjaya Lakkireddy
Journal:  J Interv Card Electrophysiol       Date:  2013-09-12       Impact factor: 1.900

2.  Non-fluoroscopic catheter tracking for fluoroscopy reduction in interventional electrophysiology.

Authors:  Philipp Sommer; Simon Kircher; Sascha Rolf; Sergio Richter; Micha Doering; Arash Arya; Andreas Bollmann; Gerhard Hindricks
Journal:  J Vis Exp       Date:  2015-05-26       Impact factor: 1.355

3.  Aegrescit medendo: orthopedic disability in electrophysiology - call for fluoroscopy elimination-review and commentary.

Authors:  Donald S Rubenstein; Benjamin B Holmes; Joseph A Manfredi; Matthew S McKillop; Peter C Netzler; Chad C Ward
Journal:  J Interv Card Electrophysiol       Date:  2022-03-08       Impact factor: 1.759