Literature DB >> 24026968

Impact of nonfluoroscopic MediGuide™ tracking system on radiation exposure in radiofrequency ablation procedures (LESS-RADS registry)-an initial experience.

Ajay Vallakati1, Yeruva Madhu Reddy, Martin Emert, Pramod Janga, Moussa C Mansour, E Kevin Heist, Rhea Pimentel, Raghuveer Dendi, Donita Atkins, Sudharani Bommana, Srijoy Mahapatra, Michael Heard, Jeremy Ruskin, Loren Berenbom, Buddhadeb Dawn, Dhanunjaya Lakkireddy.   

Abstract

BACKGROUND: Radiation exposure in the electrophysiology (EP) lab is a major concern to most electrophysiologists. A new technology, MediGuide™ nonfluoroscopic catheter tracking system, has been used for the first time in the USA recently. We intended to evaluate the efficacy of this novel catheter tracking system in reducing radiation exposure.
METHODS: We performed a prospective observational study by comparing the radiation exposure with MediGuide™ system to that of conventional mapping systems. The first 45 EP procedures performed with the MediGuide™ system were compared to 45 matched patients undergoing similar procedures during the same time frame using conventional mapping systems (CARTO and NavX) and fluoroscopy. We collected and compared baseline characteristics, procedural variables including fluoroscopic exposure between both groups.
RESULTS: Forty-five patients underwent EP procedures using the MediGuide™ technology. They were matched with an equal number of patients with conventional mapping systems. Of the 45 patients included in the study, 33 underwent right atrial flutter ablations, 5 underwent atrioventricular nodal reentrant tachycardia ablations, 4 underwent ablation of Wolf-Parkinson-White syndrome, and 3 underwent EP studies with no ablation. There were no differences in mean age, gender distribution, and body mass index between the groups. Procedure duration in the MediGuide™ group was significantly lower than the duration in the conventional group (103 vs. 142 min, p = 0.03). The fluoroscopic time was significantly less during the procedures performed with the MediGuide™ technology when compared to the control group (8 vs. 21 min, p < 0.001). No major complications occurred during the procedures in either group.
CONCLUSION: MediGuide™, a new nonfluoroscopic catheter tracking system, is associated with more than a 50 % reduction in fluoroscopic time when compared to conventional mapping systems.

Entities:  

Mesh:

Year:  2013        PMID: 24026968     DOI: 10.1007/s10840-013-9825-3

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  12 in total

1.  Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

Authors:  Sascha Rolf; Philipp Sommer; Thomas Gaspar; Silke John; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-07-07

Review 2.  Medical positioning system: a technical report.

Authors:  Moshe Y Flugelman; Avinoam Shiran; Danielle Nusimovici-Avadis; Liat Schwartz; Adrian Herscovici; Amit Cohen; Rona Shofti; Basil S Lewis; Andreas Luchner; Andreas Jeron
Journal:  EuroIntervention       Date:  2008-05       Impact factor: 6.534

3.  Nonfluoroscopic sensor-guided navigation of intracardiac electrophysiology catheters within prerecorded cine loops.

Authors:  Christopher Piorkowski; Gerhard Hindricks
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-08

4.  Nonfluoroscopic, in vivo navigation and mapping technology.

Authors:  S A Ben-Haim; D Osadchy; I Schuster; L Gepstein; G Hayam; M E Josephson
Journal:  Nat Med       Date:  1996-12       Impact factor: 53.440

5.  [Non-fluoroscopic catheter tracking: the MediGuide™ system].

Authors:  Philipp Sommer; S Rolf; S Richter; G Hindricks; C Piorkowski
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2012-11-21

6.  Enhancement of intracardiac navigation by new GPS-guided location system (MediGuide Technologies).

Authors:  T Gaspar; S Kircher; A Arya; P Sommer; S Rolf; G Hindricks; C Piorkowski
Journal:  Europace       Date:  2012-08       Impact factor: 5.214

7.  First-in-man (FIM) experience with the Magnetic Medical Positioning System (MPS) for intracoronary navigation.

Authors:  Andreas Jeron; Sabine Fredersdorf; Kurt Debl; Eitan Oren; Alon Izmirli; Alexander Peleg; Anton Nekovar; Adrian Herscovici; Günter A Riegger; Andreas Luchner
Journal:  EuroIntervention       Date:  2009-11       Impact factor: 6.534

8.  Use of a new non-fluoroscopic three-dimensional mapping system in type I atrial flutter ablation.

Authors:  Thierry Verbeet; José Castro; Marielle Morissens; Emmanuel T Ngoc; Pierre Decoodt
Journal:  Pacing Clin Electrophysiol       Date:  2005-01       Impact factor: 1.976

9.  MediGuide in supraventricular tachycardia: initial experience from a multicentre registry.

Authors:  Philipp Sommer; Christopher Piorkowski; Thomas Gaspar; Charlotte Eitel; Michael Derndorfer; Martin Martinek; Helmut Pürerfellner; Arash Arya; Gerhard Hindricks; Sascha Rolf
Journal:  Europace       Date:  2013-04-23       Impact factor: 5.214

10.  Initial experience in ablation of typical atrial flutter using a novel three-dimensional catheter tracking system.

Authors:  Philipp Sommer; Agnieszka Wojdyla-Hordynska; Sascha Rolf; Thomas Gaspar; Charlotte Eitel; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Europace       Date:  2012-08-02       Impact factor: 5.214

View more
  4 in total

Review 1.  MediGuide-impact on catheter ablation techniques and workflow.

Authors:  Jayasree Pillarisetti; Arun Kanmanthareddy; Yeruva Madhu Reddy; Dhanunjaya Lakkireddy
Journal:  J Interv Card Electrophysiol       Date:  2014-06-14       Impact factor: 1.900

2.  Non-fluoroscopic catheter tracking for fluoroscopy reduction in interventional electrophysiology.

Authors:  Philipp Sommer; Simon Kircher; Sascha Rolf; Sergio Richter; Micha Doering; Arash Arya; Andreas Bollmann; Gerhard Hindricks
Journal:  J Vis Exp       Date:  2015-05-26       Impact factor: 1.355

3.  MediGuide-assisted atrial flutter ablation in a patient with a HeartMate II left ventricular assist device.

Authors:  Hien Kiem Nguyen Thanh; Jason Andrade; Katia Dyrda; Bernard Thibault; Paul Khairy; Laurent Macle
Journal:  HeartRhythm Case Rep       Date:  2015-03-30

4.  Ablation of idiopathic ventricular arrhythmia using zero-fluoroscopy approach with equivalent efficacy and less fatigue: A multicenter comparative study.

Authors:  Yan Wang; Guang Zhi Chen; Yan Yao; Yang Bai; Hui Min Chu; Ke Zhong Ma; Reginald Liew; Hao Liu; Guo Qiang Zhong; Yu Mei Xue; Shu Lin Wu; Yi Fu Li; Chun Xia Zhao; Qi Gong Liu; Li Lin; Lin Wang; Dao Wen Wang
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.