Literature DB >> 20870383

In vivo knee kinematics in patients with bilateral total knee arthroplasty of 2 designs.

Nobukazu Okamoto1, Leigh Breslauer, Anthony K Hedley, Hiroshi Mizuta, Scott A Banks.   

Abstract

Many younger and highly active patients desire to achieve high flexion after total knee arthroplasty. This study's purpose was to determine if a contemporary total knee arthroplasty design improved functional knee flexion compared with a traditional total knee arthroplasty in patients living a Western lifestyle. Ten patients with bilateral total knee arthroplasty of 2 types were studied during weight-bearing lunge, kneeling, and stair activities using fluoroscopic imaging. There were no differences in maximum knee flexion during lunging or kneeling. Statistically significant differences in tibial rotation and condylar translation were observed during the 3 activities. Although several joint kinematic differences were observed, no important functional differences were observed in clinically excellent, high performing subjects with bilateral total knee arthroplasty of 2 types.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20870383     DOI: 10.1016/j.arth.2010.07.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Less femorotibial rotation and AP translation in deep-dished total knee arthroplasty. An intraoperative kinematic study using navigation.

Authors:  Philippe Massin; Patrick Boyer; Marc Sabourin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-05       Impact factor: 4.342

2.  Assessment of Knee Kinematics in Older Adults Using High-Speed Stereo Radiography.

Authors:  Vasiliki Kefala; Adam J Cyr; Michael D Harris; Donald R Hume; Bradley S Davidson; Raymond H Kim; Kevin B Shelburne
Journal:  Med Sci Sports Exerc       Date:  2017-11       Impact factor: 5.411

3.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

4.  Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Joseph T Lynch; Jennie M Scarvell; Catherine R Galvin; Paul N Smith; Diana M Perriman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-03       Impact factor: 4.342

Review 5.  Functional imaging in OA: role of imaging in the evaluation of tissue biomechanics.

Authors:  C P Neu
Journal:  Osteoarthritis Cartilage       Date:  2014-10       Impact factor: 6.576

6.  Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised? A pulsed fluoroscopic investigation.

Authors:  G Scott; M A Imam; A Eifert; M A R Freeman; V Pinskerova; R E Field; J Skinner; S A Banks
Journal:  Bone Joint Res       Date:  2016-03       Impact factor: 5.853

7.  Comparison of in vivo kinematics of total knee arthroplasty between cruciate retaining and cruciate substituting insert.

Authors:  Keiji Iwamoto; Takaharu Yamazaki; Kazuomi Sugamoto; Tetsuya Tomita
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2021-10-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.