Literature DB >> 23095073

Three-dimensional quantification of pretorqued nickel-titanium wires in edgewise and prescription brackets.

Nitika Mittal1, Zeyang Xia, Jie Chen, Kelton T Stewart, Sean Shih-Yao Liu.   

Abstract

OBJECTIVE: To quantify the three-dimensional moments and forces produced by pretorqued nickel-titanium (NiTi) rectangular archwires fully engaged in 0.018- and 0.022-inch slots of central incisor and molar edgewise and prescription brackets.
MATERIALS AND METHODS: Ten identical acrylic dental models with retroclined maxillary incisors were fabricated for bonding with various bracket-wire combinations. Edgewise, Roth, and MBT brackets with 0.018- and 0.022-inch slots were bonded in a simulated 2 × 4 clinical scenario. The left central incisor and molar were sectioned and attached to load cells. Correspondingly sized straight and pretorqued NiTi archwires were ligated to the brackets using 0.010-inch ligatures. Each load cell simultaneously measured three force (Fx, Fy, Fz) and three moment (Mx, My, Mz) components. The faciolingual, mesiodistal, and inciso-occluso/apical axes of the teeth corresponded to the x, y, and z axes of the load cells, respectively. Each wire was removed and retested seven times. Three-way analysis of variance (ANOVA) examined the effects of wire type, wire size, and bracket type on the measured orthodontic load systems. Interactions among the three effects were examined and pair-wise comparisons between significant combinations were performed.
RESULTS: The force and moment components on each tooth were quantified according to their local coordinate axes. The three-way ANOVA interaction terms were significant for all force and moment measurements (P < .05), except for Fy (P > .05).
CONCLUSION: The pretorqued wire generates a significantly larger incisor facial crown torquing moment in the MBT prescription compared to Roth, edgewise, and the straight NiTi wire.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23095073      PMCID: PMC8763072          DOI: 10.2319/062812-532.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  17 in total

1.  Torque capacity of metal and plastic brackets with reference to materials, application, technology and biomechanics.

Authors:  Henner Gmyrek; Christoph Bourauel; Gert Richter; Winfried Harzer
Journal:  J Orofac Orthop       Date:  2002-03       Impact factor: 1.938

2.  Biomechanics of torque from twisted rectangular archwires. A finite element investigation.

Authors:  Vijay Jayade; Satish Annigeri; Chetan Jayade; Punit Thawani
Journal:  Angle Orthod       Date:  2007-03       Impact factor: 2.079

3.  Choosing a pre-adjusted orthodontic appliance prescription for anterior teeth.

Authors:  Eleanor Thickett; Nigel G Taylor; Trevor Hodge
Journal:  J Orthod       Date:  2007-06

4.  Three-dimensional orthodontic force measurements.

Authors:  Hisham M Badawi; Roger W Toogood; Jason P R Carey; Giseon Heo; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-10       Impact factor: 2.650

5.  Comparison of the orthodontic load systems created with elastomeric power chain to close extraction spaces on different rectangular archwires.

Authors:  Catherine Kroczek; Katherine Kula; Kelton Stewart; James Baldwin; Tie Fu; Jie Chen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-03       Impact factor: 2.650

6.  The six keys to normal occlusion.

Authors:  L F Andrews
Journal:  Am J Orthod       Date:  1972-09

7.  Moments with the edgewise appliance: incisor torque control.

Authors:  R J Isaacson; S J Lindauer; L K Rubenstein
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-05       Impact factor: 2.650

8.  Quantification of three-dimensional orthodontic force systems of T-loop archwires.

Authors:  Jie Chen; Serkis C Isikbay; Edward J Brizendine
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

Review 9.  Torque expression in stainless steel orthodontic brackets. A systematic review.

Authors:  Amy Archambault; Ryan Lacoursiere; Hisham Badawi; Paul W Major; Jason Carey; Carlos Flores-Mir
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

10.  A comparison of torque expression between stainless steel, titanium molybdenum alloy, and copper nickel titanium wires in metallic self-ligating brackets.

Authors:  Amy Archambault; Thomas W Major; Jason P Carey; Giseon Heo; Hisham Badawi; Paul W Major
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

View more
  4 in total

1.  Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

Authors:  Ricardo Lima Shintcovsk; Roberto Soares da Silva Júnior; Larry White; Lidia Parsekian Martins; Renato Parsekian Martins
Journal:  Angle Orthod       Date:  2018-05-15       Impact factor: 2.079

2.  Torque efficiency of different archwires in 0.018- and 0.022-inch conventional brackets.

Authors:  Iosif Sifakakis; Nikolaos Pandis; Margarita Makou; Theodore Eliades; Christos Katsaros; Christoph Bourauel
Journal:  Angle Orthod       Date:  2013-05-16       Impact factor: 2.079

3.  A Comparison of the Ligation Torque Expression of a Ribbonwise Bracket-Archwire Combination and a Conventional Combination: A Primary Study.

Authors:  Bin Lin; Feifei Jiang; Jie Chen; Jiaxing Liang
Journal:  Int J Clin Pract       Date:  2022-09-28       Impact factor: 3.149

4.  Biomechanical investigation of orthodontic treatment planning based on orthodontic force measurement and finite element method before implementation: A case study.

Authors:  Jianlei Wu; Yunfeng Liu; Jianxing Zhang; Wei Peng; Xianfeng Jiang
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.