Literature DB >> 22381486

Comparison of the orthodontic load systems created with elastomeric power chain to close extraction spaces on different rectangular archwires.

Catherine Kroczek1, Katherine Kula2, Kelton Stewart3, James Baldwin4, Tie Fu5, Jie Chen6.   

Abstract

INTRODUCTION: The 3-dimensional load system (forces and moments) was quantified at the canine bracket during space closure with sliding mechanics with elastomeric chain on dry and wet stainless steel and beta-titanium 0.019 × 0.025-in archwires.
METHODS: A custom-made maxillary dentoform simulating first premolar extractions was attached to an orthodontic force tester. The canine was attached to a load cell through an adaptor with silicone simulating the periodontal ligament. The orthodontic force tester simultaneously measured the entire load system produced at the canine bracket by an elastomeric chain. The effects of archwire material, time (activation and 1 hour), and lubrication were analyzed by using 3-way repeated measures analysis of variance (ANOVA, α = 0.05).
RESULTS: Stainless steel provided a greater (P = 0.001) load system than did beta-titanium. The force was greatest on the canine in the lingual axis. The greatest moment was about the y-axis. The moment-to-force ratio, the most critical ratio, was greater for beta-titanium than stainless steel; however, both were close to the ideal 10:1.
CONCLUSIONS: With a stainless steel archwire for retraction sliding mechanics, a canine will experience a greater load system in all 3 dimensions than with a beta-titanium wire. Both archwires produced a moment-to-force ratio adequate for translation.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22381486     DOI: 10.1016/j.ajodo.2011.09.007

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Biomechanical validation of an artificial tooth-periodontal ligament-bone complex for in vitro orthodontic load measurement.

Authors:  Zeyang Xia; Jie Chen
Journal:  Angle Orthod       Date:  2012-09-12       Impact factor: 2.079

2.  Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

Authors:  Ricardo Lima Shintcovsk; Roberto Soares da Silva Júnior; Larry White; Lidia Parsekian Martins; Renato Parsekian Martins
Journal:  Angle Orthod       Date:  2018-05-15       Impact factor: 2.079

3.  Three-dimensional quantification of pretorqued nickel-titanium wires in edgewise and prescription brackets.

Authors:  Nitika Mittal; Zeyang Xia; Jie Chen; Kelton T Stewart; Sean Shih-Yao Liu
Journal:  Angle Orthod       Date:  2012-10-24       Impact factor: 2.079

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.