Literature DB >> 17545296

Choosing a pre-adjusted orthodontic appliance prescription for anterior teeth.

Eleanor Thickett1, Nigel G Taylor, Trevor Hodge.   

Abstract

A common orthodontic task is to correct anterior tooth position using brackets whose torque, tip and in-out are pre-adjusted. Bracket prescription greatly influences final aesthetics and function. Pre-adjusted orthodontic brackets have in-built prescriptions of torque, tip and in-out which are optimized for average cases. Refinement of tooth position can be achieved by archwire adjustment or archwire auxiliaries. Modifications to bracket position such as inversion can also help achieve individual tooth movements. Planning bracket position must be considered at the outset of treatment to achieve the maximum benefit. A number of clinical scenarios will be discussed including: a Class II division 1 malocclusion with lateral incisors palatally displaced, and another case with absent lateral incisors for space closure. Also, Class III malocclusions with consideration given to: canine angulation; a palatally displaced canine requiring labial movement; absent upper central incisors (space closure), and finally, a Class III case where incisor inclination requires consideration. By using a typodont to illustrate some of the points, this article aims to (1) show how three pre-adjusted orthodontic bracket systems (Andrews, Roth and MBT) vary significantly in their ability to influence tooth position and appearance; (2) inform clinicians how modified bracket position can influence tooth position.

Entities:  

Mesh:

Year:  2007        PMID: 17545296     DOI: 10.1179/146531207225021996

Source DB:  PubMed          Journal:  J Orthod        ISSN: 1465-3125


  4 in total

1.  The Effects of Increased Maxillary Canine Bracket Angulation on Tooth Movement and Alignment Efficiency: A Prospective Clinical Study.

Authors:  Murat Türedi; Sabahat Yazıcıoğlu
Journal:  Turk J Orthod       Date:  2022-03

2.  Three-dimensional quantification of pretorqued nickel-titanium wires in edgewise and prescription brackets.

Authors:  Nitika Mittal; Zeyang Xia; Jie Chen; Kelton T Stewart; Sean Shih-Yao Liu
Journal:  Angle Orthod       Date:  2012-10-24       Impact factor: 2.079

3.  Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets.

Authors:  Shiva Alavi; Farnaz Tajmirriahi
Journal:  Dent Res J (Isfahan)       Date:  2016-09

4.  A Retrospective Clinical Audit of Bracket Failure among Patients Undergoing Orthodontic Therapy.

Authors:  Dashrath Kafle; Rajeev Kumar Mishra; Md Riasat Hasan; Takashi Saito
Journal:  Int J Dent       Date:  2020-12-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.