Literature DB >> 23066456

Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique.

Ritesh Kumar Soni1, Surender Mohan Mehta, Bhanu Awasthi, Janith Lal Singh, Amit Kumar, Lokesh Thakur, Sujit Kumar Tripathy.   

Abstract

BACKGROUND: Distal interlocking screw insertion in intramedullary nailing of long-bone fracture is a challenging task for orthopedic surgeons. It is difficult particularly when the surgeon is in his learning stage or when image intensifier is not available. We describe a radiation-free technique of distal interlocking screw insertion which is easy and practicable.
MATERIALS AND METHODS: In this technique, a same length nail is placed over the skin (outer nail) and through its distal-most screw hole, a 3.2 mm drill bit is inserted to drill the distal locking screw hole of the intramedullary nail (inner nail). With a small skin incision over the distal screw holes, the distal-most screw hole is identified; the bone window overlying the screw hole is widened with an awl and a locking bolt is inserted with a washer under direct visualization. The other distal interlocking screw is simply drilled by matching the other three holes of the outer and inner nails. We have operated 86 patients (39 femoral shaft fracture and 47 tibial shaft fracture) in 1 year where this technique was used. There were 41 open fracture and 45 closed fracture.
RESULTS: Within 6 months of follow-up, bony union was achieved in 36 of 39 femur fractures and 45 of 47 tibial fractures. No unwanted complications were observed during the postoperative period and in follow-up.
CONCLUSION: This method of radiation-free distal interlocking screw insertion is simple and can be used in third world country where image intensifier facility is not available. However, surgeons are encouraged to use image intensifier facility where the facility is available.

Entities:  

Keywords:  Intramedually nail; femur fracture; radiation; tibia frcature

Year:  2012        PMID: 23066456      PMCID: PMC3461770          DOI: 10.4103/2006-8808.100346

Source DB:  PubMed          Journal:  J Surg Tech Case Rep        ISSN: 2006-8808


INTRODUCTION

Intramedullary nailing is the standard treatment method for closed and most of the open fractures of the long-bone diaphysis.[12] Targeting the distal holes of the intrameduallry (IM) nail for insertion of distal interlocking screws remain a challenge for the orthopedic surgeons. Proximally based distal targeting devices have not proved useful till date due to the deformation of the nail inside the medullary canal;[3] hence a free hand technique for insertion of distal interlocking screws under fluoroscopic guidance remains the most popular method. This process is technically demanding, time consuming, and afflicted to considerable radiation exposure of the patient and the surgical personnel.[4-10] Radiation induced cancer is a growing problem among orthopedic surgeons, associated with a relative risk for cancer of 5.37 with respect to the general population;[11] malignancies of exposed personnel range from cancers of solid organs (i.e., thyroid and pancreas), to skin and hematopoietic cancers.[12] In female orthopedic surgeons the standardized prevalence ratio for all cancers is 1.9 and 2.88 specifically for breast cancer when compared to the general population. According to Sanders et al.[5] who put dosimeter rings on the surgeon's hand for all orthopedic fluoroscopy cases, there is increased risk of positive reading with increased fluoroscopy time. The risk increased further during intramedullary nailing procedures. Gugala et al. reported a fluoroscopy time of 36 seconds for placement of two screws in the tibia,[13] whereas Suhm et al. stated intense use of fluoroscopy during freehand locking of 108 seconds per screw.[14] Factors such as experience level of the operator or experimental/clinical setup might contribute to this scattering. In the investigation of Kirousis et al.[15] a complete tibia nailing procedure required 72 seconds of radiation and resulted in an effective dose of 0.04 mSv for the operating surgeon and 0.11 mSv for the C-arm technician. A number of techniques and systems have recently been developed to minimize the exposure of the radiation to the surgeons and the accompanying staff.[1316-19] Penning et al. have reported 100% accuracy for the placement of distal interlocking screws using Orthofix femoral and tibial intramedullary rods equipped with distal targeting devices.[20] All these techniques are either not available in developing countries or are still in their developmental stages. Secondly, insertion of distal interlocking screws requires an image intensifier and an experienced radiographer which sometimes are not available in developing and poor countries. There is no study till date that describes the techniques of insertion of distal interlocking screws without the use of image intensifier or the X-rays. We hypothesized that our described technique in this article is a valid method of radiation-free insertion of distal interlocking screw in tibial and femoral nailing. The surgical technique, tips and pearls, and treatment outcome of a group of patients treated with IM nail without the help of image intensifier over a period of 1 year are described.

SURGICAL TECHNIQUE

This technique in our setup had come more out of compulsion than anything else, due to lack of good intraoperative imaging modalities in the past. The method of inserting interlocking nails remains standard. After insertion to the fractured bone, a same length nail is juxtaposed over the limb and held in position with two long drill bits introduced through the proximal zig [as shown in the Figures 1–3]. After aligning the outer nail with the proximal zig, a 5–6 cm long incision is given centering over the estimated site of the distal locking screws, the underlying long bone cortex is hence exposed [Figure 4a]. Now, through the distal most hole of the outer nail, the near cortex is drilled with a 3.2 mm drill bit. Using a corresponding bone awl, the hole is slightly enlarged [Figure 4b]. The intramedullary blood is then suctioned off from the hole with a Ryles tube (no. 12, 14) attached to a suction tube [Figure 5a]. Following this, the intramedullary nail and the distal hole could be clearly visualized [Figure 5b]. Once visualized, the tip of the awl is inserted into the hole and it is rotated perpendicular to the nail; this creates the entry point for the subsequent drill bit. A corresponding drill bit is then inserted through this hole and the opposite cortex drilled. The length of the screw is hence determined. Now, a free drill bit is passed through the distal locking holes of both the nails, this fixes the outer nail at three points [Figure 6]. With this alignment, the antecedent distal locking hole is usually a simple “drill and go.” But, if doubt exists, a similar procedure could be applied for this hole as well. Since the hole in the near cortex is slightly enlarged, a washer is usually used to secure the locking screw heads [Figures 7–9].
Figure 1

Instruments needed for interlocking

Figure 3

Antero-posterior play while keeping nail over nail

Figure 4

(a) Incision given for tibial interlocking; (b) Enlargement of the near cortex using bone awl

Figure 5

(a) Using Ryle's tube to suction intramedullary blood; (b) Enlarged distal tibial intramedullary nail hole

Figure 6

(a) The distal hole in the intramedullary nail seen through bone; (b) Insertion of distal interlocking screw with washer

Figure 7

Technique of inserting antecedent distal locking screws

Figure 9

(a) Wound site; (b) Postoperative photograph of fracture femur patient

Instruments needed for interlocking (a) Picture depicting outer nail in juxtaposition (nail on nail); (b) Illustration showing the “nail on nail” technique with three point fixation Antero-posterior play while keeping nail over nail (a) Incision given for tibial interlocking; (b) Enlargement of the near cortex using bone awl (a) Using Ryle's tube to suction intramedullary blood; (b) Enlarged distal tibial intramedullary nail hole (a) The distal hole in the intramedullary nail seen through bone; (b) Insertion of distal interlocking screw with washer Technique of inserting antecedent distal locking screws Postoperative radiograph of patient (a) Wound site; (b) Postoperative photograph of fracture femur patient In summary, the key to our technique is the direct visualization of the distal locking holes combined with the use of corresponding bone awl and three point fixation of a juxtaposed outer nail.

MATERIALS AND METHODS

Eighty-six cases of femoral and tibial shaft fractures were operated in our institute over a period of 1 year (January 2010–2011). Out of them, 73 were males and 13 were females. Of these, 39 had femoral shaft fractures and 47 had tibial shaft fractures. There were 41 open fractures (Gustilo Anderson grade 1–3B) and 45 closed fractures. Average age of the patients was 35.4 years (range 14–76 years). In all these cases, both of the distal screws were inserted without the use of image intensifier. Average time taken for inserting the distal screws was 11 minutes (range 5–18 minutes). More than two attempts of drilling near cortex were made in two cases. We resorted to placing bone grafts in addition to washers in these cases. All our patients were treated with the Simplified Universal Nails (SUN) supplied by the A.O. group. Interlocking was done in the lateral position in all cases of fracture femur and in supine position in fracture tibia. All the patients were mobilized immediately after surgery with partial weight bearing. Isometric quadriceps exercises and knee flexion were encouraged as tolerated by the patient. They were followed up after 3 weeks, 6 weeks, 3 months, and 6 months of surgery.

RESULTS

In the postoperative period, three patients had infection that needed debridement and antibiotic therapy. At the end of 6 months, radiographic union was observed in 36 of 39 femur fractures and 45 of 47 tibial fractures. The five patients with nonunion had open fracture. None of the patients complained of pain or tenderness at the distal screw sites. No clinical or radiological evidences of screw or nail breakage or fracture were noticed at the distal screw site.

DISCUSSION

When a nail is inserted into a long bone, it is likely to bend according to the curvature of the intramedullary canal.[3] Exact orientation of the distal interlocking holes is, hence, difficult to predict. Usually surgeons use repeated fluoroscopy to insert the screws in a freehand manner. In many centers of developing and poor countries, image intensifier facility is not available; hence surgeons adopt various indigenous techniques for distal screw insertion. Our technique is especially suited for institutions where either image intensifier or expert radiographer is not available in the operation theatre. This technique is different from the “nail on nail” technique described by Rohilla et al.,[3] because it does not involve the use of “sounding technique,” rather it aims at direct visualization of the locking hole, drilling under vision and the use of corresponding bone awl. The major advantage of our technique is that since everything is being done under direct vision, the chance of misplaced screws is less and the operating time is less. Again under direct vision, the chance of slippage of the drill bit on the bone is less. Tanna et al.[1] also described similar technique using K-wires which is image intensifier independent. However, it still depends on single radiographic imaging for estimating the location of the distal hole. In our technique, image intensifier or X-rays are very rarely used intraoperatively. While the success of their technique relies on interpretation of X-rays, our method relies on appropriate alignment of the outer nail and adequate widening of the near cortex so that the distal holes could be visualized. There are few potential drawbacks of the proposed technique. The length of incision for interlocking distal screws is larger than that those given during the free hand technique (about 5–6 cm compared to 1–2 cm). We have not compared it with any other method of interlocking; hence claims of superiority are at present largely anecdotal. Further studies are needed to evaluate the effect of widening of the near cortex on fracture healing. So far, we have not encountered any fracture through distal screws with our technique. A big hole around distal screw may act as stress riser. The potential complications of iatrogenic fracture, delayed union or nonunion cannot be avoided with our proposed technique. Definitely this technique cannot be employed in situations where bone quality is poor or in osteoporotic individuals. A snugly fit screw provides better biomechanical strength and hence one may argue about the stability of the fixation with the described technique. Use of washer beneath the screw in larger hole may increase the stability. The cause of nonunion in five cases is difficult to explain in the present series. All patients with nonunion had open fracture which is an important cause for nonunion. Thus, it is difficult to explain whether the nonunion is because of open nature of injury or because of biomechanical disadvantage of distal screw interlocking in a wide hole. Other than the risk of radiation exposure, distal screw insertion under fluoroscopy is definitely ideal and should be performed where the facility is available. Our described technique is particularly useful in situations where image intensifier or trained radiographers are not available. It is hence more suitable for rural hospitals and third world countries or in situations where image intensifier have failed technically. It does not need any special equipment and learning curve is also not very steep.
  19 in total

Review 1.  Occupational radiation exposure to the surgeon.

Authors:  Gordon Singer
Journal:  J Am Acad Orthop Surg       Date:  2005 Jan-Feb       Impact factor: 3.020

2.  Prevalence of cancer in female orthopaedic surgeons in the United States.

Authors:  Loretta B Chou; Christopher A Cox; Joanna J Tung; Alex H S Harris; Daria Brooks-Terrell; Weiva Sieh
Journal:  J Bone Joint Surg Am       Date:  2010-01       Impact factor: 5.284

3.  The deformation of small diameter solid tibial nails with unreamed intramedullary insertion.

Authors:  C Krettek; J Mannss; B Könemann; T Miclau; P Schandelmaier; H Tscherne
Journal:  J Biomech       Date:  1997-04       Impact factor: 2.712

4.  Locking nailing: an aid to distal targetting.

Authors:  I Hudson
Journal:  Injury       Date:  1989-05       Impact factor: 2.586

5.  Interlocking medullary nails--radiation doses in distal targeting.

Authors:  S Skjeldal; S Backe
Journal:  Arch Orthop Trauma Surg       Date:  1987

6.  Radiation exposure to the surgeon during closed interlocking intramedullary nailing.

Authors:  P E Levin; R W Schoen; B D Browner
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

7.  Interlocking tibial nailing without an image intensifier.

Authors:  D D Tanna
Journal:  J Bone Joint Surg Br       Date:  1994-07

8.  Radiation exposure to an orthopedic surgeon.

Authors:  T P Barry
Journal:  Clin Orthop Relat Res       Date:  1984 Jan-Feb       Impact factor: 4.176

9.  Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures.

Authors:  M E Miller; M L Davis; C R MacClean; J G Davis; B L Smith; J R Humphries
Journal:  J Bone Joint Surg Am       Date:  1983-01       Impact factor: 5.284

10.  Dosimetry during intramedullary nailing of the tibia.

Authors:  George Kirousis; Harry Delis; Panagiotis Megas; Elias Lambiris; George Panayiotakis
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more
  1 in total

1.  Preliminary Results with the Shape Memory Nail: A Self-contained Distal Locking Mechanism for Diaphyseal Femur Fractures.

Authors:  Nando Ferreira; Luan Nieuwoudt
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Sep-Dec
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.