Literature DB >> 2805490

Radiation exposure from fluoroscopy during orthopedic surgical procedures.

S A Riley1.   

Abstract

The use of fluoroscopy has enabled orthopedic surgeons to become technically more proficient. In addition, these surgical procedures tend to have less associated patient morbidity by decreasing operative time and minimizing the area of the operative field. The trade-off, however, may be an increased risk of radiation exposure to the surgeon on an annual or lifetime basis. The current study was designed to determine the amount of radiation received by the primary surgeon and the first assistant during selected surgical procedures involving the use of fluoroscopy. Five body sites exposed to radiation were monitored for dosage. The results of this study indicate that with appropriate usage, (1) radiation exposure from fluoroscopy is relatively low; (2) the surgeon's dominant hand receives the most exposure per case; and (3) proper maintenance and calibration of fluoroscopic machines are important factors in reducing exposure risks. Therefore, with proper precautions, the use of fluoroscopy in orthopedic procedures can remain a safe practice.

Entities:  

Mesh:

Year:  1989        PMID: 2805490

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  Radiation exposure during 3D fluoroscopy of the knee: an experimental study.

Authors:  T Tharmviboonsri; K Riansuwan; A Nitising; B Mahaisavariya
Journal:  Eur J Trauma Emerg Surg       Date:  2011-11-19       Impact factor: 3.693

2.  Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training.

Authors:  M J Oddy; C H Aldam
Journal:  Ann R Coll Surg Engl       Date:  2006-05       Impact factor: 1.891

3.  [Precision of guidewire placement--can it be improved by applying the new, isocentric aiming principle?].

Authors:  N Suhm; P Toggwiler; M Hänni; V Quarz; A Appelt
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

Review 4.  C-arm fluoroscopy in orthopaedic surgical practice.

Authors:  Ishaq Ojodu; Ayodele Ogunsemoyin; Sascha Hopp; Tim Pohlemann; Oluwole Ige; Oluwaseun Akinola
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-23

Review 5.  Occupational health related concerns among surgeons.

Authors:  Anjuman Gul Memon; Zahid Naeem; Atif Zaman; Faryal Zahid
Journal:  Int J Health Sci (Qassim)       Date:  2016-04

6.  A New Preoperative Planning Technique Can Reduce Radiation Exposure During the Performance of Medial Opening-Wedge High Tibial Osteotomy.

Authors:  Elad Spitzer; Joseph J Ruzbarsky; John B Doyle; Kaitlyn L Yin; Robert G Marx
Journal:  HSS J       Date:  2017-12-26

7.  Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique.

Authors:  Ritesh Kumar Soni; Surender Mohan Mehta; Bhanu Awasthi; Janith Lal Singh; Amit Kumar; Lokesh Thakur; Sujit Kumar Tripathy
Journal:  J Surg Tech Case Rep       Date:  2012-01

Review 8.  Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: a systematic review.

Authors:  Chandrasekharan Nair Kesavachandran; Frank Haamann; Albert Nienhaus
Journal:  Eur J Med Res       Date:  2012-10-30       Impact factor: 2.175

9.  Exposure of the surgical team to ionizing radiation during orthopedic surgical procedures.

Authors:  Evandro Pereira Palácio; André Araújo Ribeiro; Bruno Moreira Gavassi; Gabriel Guimarães Di Stasi; José Antônio Galbiatti; Alcides Durigam Junior; Roberto Ryuiti Mizobuchi
Journal:  Rev Bras Ortop       Date:  2014-04-25

10.  FRACTURES OF THE DISTAL EXTREMITY OF THE TIBIA TREATED WITH INTRAMEDULLARY NAIL OR BRIDGE PLATE: COMPARISON OF RADIATION EXPOSURE DURATION BETWEEN THE TWO METHODS.

Authors:  Pedro José Labronici; Fábio Soares Lyra; Ildeu Leite Moreira; Rolix Hoffmann; José Sergio Franco; Paulo Roberto Barbosa de Toledo Lourenço; Gustavo José Labronici
Journal:  Rev Bras Ortop       Date:  2015-11-16
View more