Literature DB >> 9075008

The deformation of small diameter solid tibial nails with unreamed intramedullary insertion.

C Krettek1, J Mannss, B Könemann, T Miclau, P Schandelmaier, H Tscherne.   

Abstract

'Radiation-independent' aiming systems for the placement of interlocking screws in intramedullary tibial nails have failed because of insertional related nail deformation. Prior to the development of these distal aiming systems, the variable position of the nails' interlocking holes after insertion must be known. In this study, the amount and direction of implant deformation of solid stainless-steel tibial nails (diameters of 8 and 9 mm, n = 20) were analyzed. Measurement of implant deflection (three translations, three angles) in the center of distal transverse locking hole was performed with a three-dimensional-magnetic motion tracker system after nail insertion in paired human cadaver tibiae. The results showed combined mean lateral translation of the 8 and 9 mm nails (n = 20) of -4.5 +/- 3.5 mm (range: 14.3 mm) and dorsal translation -7.8 +/- 5.8 mm (range: 19.2 mm). The combined mean rotational deformation about the longitudinal axis of the nail was 0.3 +/- 0.7 degree (range: 2.4 degrees). The authors conclude that a simple aiming arm, mounted on the proximal nail end alone, is not sufficient to provide accurate distal aiming.

Entities:  

Mesh:

Year:  1997        PMID: 9075008     DOI: 10.1016/s0021-9290(96)00160-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  Distal locking of tibial nails : a new device to reduce radiation exposure.

Authors:  George Anastopoulos; Panagiotis G Ntagiopoulos; Dionisios Chissas; Athanasios Papaeliou; Antonios Asimakopoulos
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

2.  Does the magnetic-guided intramedullary nailing technique shorten operation time and radiation exposure?

Authors:  Muhsin Dursun; Tughan Kalkan; Mahmut Nedim Aytekin; Ismail Celik; Mahmut Uğurlu
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-07-03

Review 3.  Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

Authors:  Yanbin Zhu; Hengrui Chang; Yiyang Yu; Wei Chen; Song Liu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-06-02       Impact factor: 3.075

4.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

5.  Contact Compliance Based Visual Feedback for Tool Alignment in Robot Assisted Bone Drilling.

Authors:  Ping-Lang Yen; Yu-Jui Chen
Journal:  Sensors (Basel)       Date:  2022-04-21       Impact factor: 3.847

6.  Electromagnetic distal targeting system does not reduce the overall operative time of the intramedullary nailing for humeral shaft fractures.

Authors:  Lawrence Camarda; Stefania Zini; Marcello Butera; Sabastin Giambartino; Ugo Mattaliano; Francesco Raso; Roberto Sciortino; Michele D'Arienzo
Journal:  J Orthop       Date:  2018-08-24

7.  A meta-analysis of external fixator versus intramedullary nails for open tibial fracture fixation.

Authors:  Xian Xu; Xu Li; Lin Liu; Wei Wu
Journal:  J Orthop Surg Res       Date:  2014-08-16       Impact factor: 2.359

8.  Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique.

Authors:  Ritesh Kumar Soni; Surender Mohan Mehta; Bhanu Awasthi; Janith Lal Singh; Amit Kumar; Lokesh Thakur; Sujit Kumar Tripathy
Journal:  J Surg Tech Case Rep       Date:  2012-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.