Literature DB >> 6692610

Radiation exposure to an orthopedic surgeon.

T P Barry.   

Abstract

Occupational radiation exposure was measured using three film badges and one ring thermoluminescent dosimeter. The radiation dose in the hospital but outside the operating room was measured as zero for the 12-month period. The measured trunk dose in the operating room was 5 mrem, and the measured dose to the head and neck region was 227 mrem. For selected orthopedic procedures a ring thermoluminescent dosimeter was worn on the left ring finger (under a lead glove when appropriate) and measured 0 mrem. The measured occupational radiation exposure to the author was well below the recommendations of the U.S. National Committee on Radiation Protection for maximal permissible dose. However, caution is advised since the long-term biologic effects of exposure to low doses of radiation are not well known. Since many factors influence the amount of radiation to individual surgeons, the data obtained are not necessarily representative.

Mesh:

Year:  1984        PMID: 6692610

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  21 in total

1.  Occupational radiation exposure from C arm fluoroscopy during common orthopaedic surgical procedures and its prevention.

Authors:  Anupam Mahajan; Sumant Samuel; Atul K Saran; M K Mahajan; M K Mam
Journal:  J Clin Diagn Res       Date:  2015-03-01

2.  Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training.

Authors:  M J Oddy; C H Aldam
Journal:  Ann R Coll Surg Engl       Date:  2006-05       Impact factor: 1.891

3.  [Precision of guidewire placement--can it be improved by applying the new, isocentric aiming principle?].

Authors:  N Suhm; P Toggwiler; M Hänni; V Quarz; A Appelt
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

4.  Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging.

Authors:  Harvey E Smith; Matthew D Welsch; Rick C Sasso; Alexander R Vaccaro
Journal:  J Spinal Cord Med       Date:  2008       Impact factor: 1.985

5.  [Effectiveness of lead thyroid shield for reducing roentgen ray exposure in trauma surgery interventions of the lower leg].

Authors:  L P Müller; J Suffner; W Mohr; J Degreif; P M Rommens
Journal:  Unfallchirurgie       Date:  1997-12

6.  Is distal locking of long nails for intertrochanteric fractures necessary? A clinical study.

Authors:  Bryan G Vopat; Patrick M Kane; Jeremy Truntzer; Philip McClure; David Paller; Emily Abbood; Christopher Born
Journal:  J Clin Orthop Trauma       Date:  2014-07-28

7.  Measuring the radiation exposed with optically stimulated luminescent dosimeters and evaluation of the total time and dose of fluoroscopy.

Authors:  Sever Çaglar; Yaşar Mahsut Dinçel; Yavuz Arıkan; Osman Nuri Özyalvaç; Barış Özkul; Ali Öner
Journal:  J Clin Orthop Trauma       Date:  2018-07-21

8.  Comparison between locked and unlocked intramedullary nails in intertrochanteric fractures.

Authors:  Riccardo Maria Lanzetti; Auro Caraffa; Domenico Lupariello; Paolo Ceccarini; Giulio Gambaracci; Luigi Meccariello; Francesco Manfreda; Daniele Maiettini; Cristina Ibáñez Vicente; Michele Scialpi; Olga Bisaccia; Giuseppe Rinonapoli; Michele Bisaccia
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-09

9.  Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience.

Authors:  Rajesh Botchu; Kassetti Ravikumar
Journal:  Indian J Orthop       Date:  2008-10       Impact factor: 1.251

10.  Radiation-free Insertion of Distal Interlocking Screw in Tibial and Femur Nailing: A Simple Technique.

Authors:  Ritesh Kumar Soni; Surender Mohan Mehta; Bhanu Awasthi; Janith Lal Singh; Amit Kumar; Lokesh Thakur; Sujit Kumar Tripathy
Journal:  J Surg Tech Case Rep       Date:  2012-01