PURPOSE: To evaluate accuracy and noise properties of a novel time-resolved, three-dimensional, three-directional phase contrast sequence with variable velocity encoding (denoted 4D-vPC) on a 3 Tesla MR system, and to investigate potential benefits and limitations of variable velocity encoding with respect to depicting blood flow patterns. MATERIALS AND METHODS: A 4D PC-MRI sequence was modified to allow variable velocity encoding (VENC) over the cardiac cycle in all three velocity directions independently. 4D-PC sequences with constant and variable VENC were compared in a rotating phantom with respect to measured velocities and noise levels. Additionally, comparison of flow patterns in the ascending aorta was performed in six healthy volunteers. RESULTS: Phantom measurements showed a linear relationship between velocity noise and velocity encoding. 4D-vPC MRI presented lower noise levels than 4D-PC both in phantom and in volunteer measurements, in agreement with theory. Volunteer comparisons revealed more consistent and detailed flow patterns in early diastole for the variable VENC sequences. CONCLUSION: Variable velocity encoding offers reduced noise levels compared with sequences with constant velocity encoding by optimizing the velocity-to-noise ratio (VNR) to the hemodynamic properties of the imaged area. Increased VNR ratios could be beneficial for blood flow visualizations of pathology in the cardiac cycle.
PURPOSE: To evaluate accuracy and noise properties of a novel time-resolved, three-dimensional, three-directional phase contrast sequence with variable velocity encoding (denoted 4D-vPC) on a 3 Tesla MR system, and to investigate potential benefits and limitations of variable velocity encoding with respect to depicting blood flow patterns. MATERIALS AND METHODS: A 4D PC-MRI sequence was modified to allow variable velocity encoding (VENC) over the cardiac cycle in all three velocity directions independently. 4D-PC sequences with constant and variable VENC were compared in a rotating phantom with respect to measured velocities and noise levels. Additionally, comparison of flow patterns in the ascending aorta was performed in six healthy volunteers. RESULTS: Phantom measurements showed a linear relationship between velocity noise and velocity encoding. 4D-vPC MRI presented lower noise levels than 4D-PC both in phantom and in volunteer measurements, in agreement with theory. Volunteer comparisons revealed more consistent and detailed flow patterns in early diastole for the variable VENC sequences. CONCLUSION: Variable velocity encoding offers reduced noise levels compared with sequences with constant velocity encoding by optimizing the velocity-to-noise ratio (VNR) to the hemodynamic properties of the imaged area. Increased VNR ratios could be beneficial for blood flow visualizations of pathology in the cardiac cycle.
Authors: Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl Journal: J Magn Reson Imaging Date: 2017-02-02 Impact factor: 4.813
Authors: Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner Journal: MAGMA Date: 2017-08-07 Impact factor: 2.310
Authors: Sean Callahan; Narayana S Singam; Michael Kendrick; M J Negahdar; Hui Wang; Marcus F Stoddard; Amir A Amini Journal: J Magn Reson Imaging Date: 2019-12-18 Impact factor: 4.813
Authors: M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby Journal: Clin Radiol Date: 2016-03-02 Impact factor: 2.350
Authors: Mikael Kanski; Johannes Töger; Katarina Steding-Ehrenborg; Christos Xanthis; Karin Markenroth Bloch; Einar Heiberg; Marcus Carlsson; Håkan Arheden Journal: BMC Med Imaging Date: 2015-06-18 Impact factor: 1.930