Literature DB >> 23060718

Correlations between magnitude of refractive error and other optical components in Korean myopes.

Sangkyu Lee1, Boyun Kim, Tae-Hoon Oh, Hyun Seung Kim.   

Abstract

PURPOSE: We evaluated ocular optical components and their interrelationships in myopic Korean patients.
METHODS: In this prospective observational study, 1,011 consecutive patients were recruited from a refractive surgery clinic. The best-corrected visual acuity was >20 / 20 in all patients. The refractive error, axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were measured by an autorefractor and partial coherence laser interferometry (IOL Master). Central corneal thickness (CCT) was measured by ORBscan II topography.
RESULTS: The refractive errors had a positive correlation with LT but negative correlations with AL, ACD, VCD, and CCT. As the axial length increased, the ACD, VCD, and CCT increased but the LT decreased. The CCT had a positive correlation with gender, refractive errors, ACD, VCD, and AL but no correlation with age. The mean CCT was increased in proportion to the increase in AL.
CONCLUSIONS: In myopic Korean patients, as axial elongation progressed, the VCD and ACD deepened and the CCT thickened but the LT decreased. The CCT had a positive correlation with the degree of myopia and the AL.

Entities:  

Keywords:  Axial length; Central corneal thickness; Koreans; Myopia; Refractive errors

Mesh:

Year:  2012        PMID: 23060718      PMCID: PMC3464315          DOI: 10.3341/kjo.2012.26.5.324

Source DB:  PubMed          Journal:  Korean J Ophthalmol        ISSN: 1011-8942


  29 in total

1.  Applanation tonometry and central corneal thickness.

Authors:  N Ehlers; T Bramsen; S Sperling
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-03

2.  Posterior corneal protrusion after PRK.

Authors:  S Shimmura; H Y Yang; H Bissen-Miyajima; J Shimazaki; K Tsubota
Journal:  Cornea       Date:  1997-11       Impact factor: 2.651

3.  Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry.

Authors:  V Yaylali; S C Kaufman; H W Thompson
Journal:  J Cataract Refract Surg       Date:  1997-11       Impact factor: 3.351

4.  Mathematics of laser in situ keratomileusis for high myopia.

Authors:  L E Probst; J J Machat
Journal:  J Cataract Refract Surg       Date:  1998-02       Impact factor: 3.351

5.  Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study.

Authors:  R C Wolfs; C C Klaver; J R Vingerling; D E Grobbee; A Hofman; P T de Jong
Journal:  Am J Ophthalmol       Date:  1997-06       Impact factor: 5.258

6.  Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students.

Authors:  D A Goss; H G Van Veen; B B Rainey; B Feng
Journal:  Optom Vis Sci       Date:  1997-07       Impact factor: 1.973

7.  A clinical study of the normal human central corneal thickness.

Authors:  F K Hansen
Journal:  Acta Ophthalmol (Copenh)       Date:  1971

8.  The effect of corneal thickness on applanation tonometry.

Authors:  M M Whitacre; R A Stein; K Hassanein
Journal:  Am J Ophthalmol       Date:  1993-05-15       Impact factor: 5.258

9.  Central corneal thickness and intraocular pressure in a Mongolian population.

Authors:  P J Foster; J Baasanhu; P H Alsbirk; D Munkhbayar; D Uranchimeg; G J Johnson
Journal:  Ophthalmology       Date:  1998-06       Impact factor: 12.079

10.  Partial coherence interferometry: a novel approach to biometry in cataract surgery.

Authors:  W Drexler; O Findl; R Menapace; G Rainer; C Vass; C K Hitzenberger; A F Fercher
Journal:  Am J Ophthalmol       Date:  1998-10       Impact factor: 5.258

View more
  1 in total

1.  Correlation between central corneal thickness and myopia.

Authors:  Michael Mimouni; Victor Flores; Yinon Shapira; Shmuel Graffi; Shmuel Levartovsky; Tzahi Sela; Gur Munzer; Igor Kaiserman
Journal:  Int Ophthalmol       Date:  2017-10-26       Impact factor: 2.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.