Literature DB >> 21908170

Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty.

Kace A Ezzet1, Juan C Hermida, Nikolai Steklov, Darryl D D'Lima.   

Abstract

Metallic femoral components with ceramic articulating surfaces can substantially lower polyethylene (PE) wear during walking activities under conditions of normal knee alignment. It is unknown whether these types of components can maintain low wear rates under conditions of knee malalignment and the harsher kinematics associated with younger, athletically active patients. Wear was measured in non-cross-linked, ethylene oxide-sterilized PE inserts against oxidized zirconium or cobalt-chrome femoral components in a knee wear simulator. The vertical load was modified to replicate knee varus malalignment of 3°, and the range of tibial rotation was increased to 20°. Mean gravimetric and volumetric wear rate over 5 million cycles was 55% lower in the oxidized zirconium group. An oxidized zirconium femoral component can significantly reduce PE wear under simulated conditions of athletically active patients with modestly malaligned total knee arthroplasty prostheses.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21908170     DOI: 10.1016/j.arth.2011.06.002

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

Review 1.  Clinical Results of Oxidized Zirconium Femoral Component in TKA. A Review of Long-Term Survival: Review Article.

Authors:  Roberto Civinini; Fabrizio Matassi; Christian Carulli; Luigi Sirleo; Andrea Cozzi Lepri; Massimo Innocenti
Journal:  HSS J       Date:  2016-07-13

2.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

3.  Does oxidized zirconium make a difference? Midterm cohort survivorship of symmetric posterior condyle posterior-stabilized total knee arthroplasty

Authors:  A. Ross Demcoe; Eric R. Bohm; David R. Hedden; Colin D. Burnell; Thomas R. Turgeon
Journal:  Can J Surg       Date:  2019-04-01       Impact factor: 2.089

4.  Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters.

Authors:  Steven P Mell; Markus A Wimmer; Joshua J Jacobs; Hannah J Lundberg
Journal:  J Mech Behav Biomed Mater       Date:  2021-10-28

5.  Improved design decreases wear in total knee arthroplasty with varus malalignment.

Authors:  Kazutaka Nishikawa; Ken Okazaki; Shuichi Matsuda; Yasutaka Tashiro; Shinya Kawahara; Hiroyuki Nakahara; Shigetoshi Okamoto; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-16       Impact factor: 4.342

6.  Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components.

Authors:  Thomas J Heyse; Marcella E Elpers; Danyal H Nawabi; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

7.  Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study.

Authors:  Anne Postler; Franziska Beyer; Cornelia Lützner; Eric Tille; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-03       Impact factor: 4.342

8.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07

9.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

10.  Alternative bearings in total knee arthroplasty: risk of early revision compared to traditional bearings: an analysis of 62,177 primary cases.

Authors:  Maria C S Inacio; Guy Cafri; Elizabeth W Paxton; Steven M Kurtz; Robert S Namba
Journal:  Acta Orthop       Date:  2013-03-14       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.