Risk factors for inflammatory pseudotumour formation following hip resurfacing.

S Glyn-Jones1, H Pandit, Y-M Kwon, H Doll, H S Gill, D W Murray.   

Abstract

Metal-on-metal hip resurfacing is commonly performed for osteoarthritis in young active patients. We have observed cystic or solid masses, which we have called inflammatory pseudotumours, arising around these devices. They may cause soft-tissue destruction with severe symptoms and a poor outcome after revision surgery. The aim of this study was to determine the incidence of and risk factors for pseudotumours that are serious enough to require revision surgery. Since 1999, 1419 metal-on-metal hip resurfacings have been implanted by our group in 1224 patients; 1.8% of the patients had a revision for pseudotumour. In this series the Kaplan-Meier cumulative revision rate for pseudotumour increased progressively with time. At eight years, in all patients, it was 4% (95% confidence interval (CI) 2.2 to 5.8). Factors significantly associated with an increase in revision rate were female gender (p < 0.001), age under 40 (p = 0.003), small components (p = 0.003), and dysplasia (p = 0.019), whereas implant type was not (p = 0.156). These factors were inter-related, however, and on fitting a Cox proportional hazard model only gender (p = 0.002) and age (p = 0.024) had a significant independent influence on revision rate; size nearly reached significance (p = 0.08). Subdividing the cohort according to significant factors, we found that the revision rate for pseudotumours in men was 0.5% (95% CI 0 to 1.1) at eight years whereas in women over 40 years old it was 6% (95% CI 2.3 to 10.1) at eight years and in women under 40 years it was 13.1% at six years (95% CI 0 to 27) (p < 0.001). We recommend that resurfacings are undertaken with caution in women, particularly those under 40 years of age but they remain a good option in young men. Further work is required to understand the aetiology of pseudotumours so that this complication can be avoided.

Entities:  

Mesh:

Year:  2009        PMID: 19949118     DOI: 10.1302/0301-620X.91B12.22287

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  82 in total

1.  High revision rate at 5 years after hip resurfacing with the Durom implant.

Authors:  Florian D Naal; Ronny Pilz; Urs Munzinger; Otmar Hersche; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2011-01-29       Impact factor: 4.176

2.  Concomitant infection and local metal reaction in patients undergoing revision of metal on metal total hip arthroplasty.

Authors:  Kyle T Judd; Nicolas Noiseux
Journal:  Iowa Orthop J       Date:  2011

3.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 4.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

5.  Reply to letter to the editor: do complication rates differ by gender after metal-on-metal hip resurfacing arthroplasty? A systematic review.

Authors:  Bryan D Haughom; Brandon J Erickson; Michael D Hellman; Joshua J Jacobs
Journal:  Clin Orthop Relat Res       Date:  2015-09-23       Impact factor: 4.176

6.  Perivascular lymphocytic infiltration is not limited to metal-on-metal bearings.

Authors:  Vincent Y Ng; Adolph V Lombardi; Keith R Berend; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

7.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

8.  Fairness to all: gender and sex in scientific reporting.

Authors:  Seth S Leopold; Lee Beadling; Matthew B Dobbs; Mark C Gebhardt; Paul A Lotke; Paul A Manner; Clare M Rimnac; Montri D Wongworawat
Journal:  Clin Orthop Relat Res       Date:  2013-11-26       Impact factor: 4.176

9.  Wear in total knee arthroplasty--just a question of polyethylene?: Metal ion release in total knee arthroplasty.

Authors:  Jan Philippe Kretzer; Joern Reinders; Robert Sonntag; Sebastien Hagmann; Marcus Streit; Sebastian Jeager; Babak Moradi
Journal:  Int Orthop       Date:  2013-11-12       Impact factor: 3.075

10.  The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements.

Authors:  Steven M Kurtz; Jeffrey M Toth; Ryan Siskey; Lauren Ciccarelli; Dan Macdonald; Jorge Isaza; Todd Lanman; Ilona Punt; Marla Steinbeck; Jan Goffin; André van Ooij
Journal:  Semin Spine Surg       Date:  2012-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.