Literature DB >> 23039631

Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: results from independently conducted FROC∕ROC studies in mammography.

Federica Zanca1, Stephen L Hillis, Filip Claus, Chantal Van Ongeval, Valerie Celis, Veerle Provoost, Hong-Jun Yoon, Hilde Bosmans.   

Abstract

PURPOSE: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings.
METHODS: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations.
RESULTS: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46].
CONCLUSIONS: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable.

Mesh:

Year:  2012        PMID: 23039631      PMCID: PMC3461051          DOI: 10.1118/1.4747262

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  48 in total

1.  Components-of-variance models and multiple-bootstrap experiments: an alternative method for random-effects, receiver operating characteristic analysis.

Authors:  S V Beiden; R F Wagner; G Campbell
Journal:  Acad Radiol       Date:  2000-05       Impact factor: 3.173

2.  Analysis of uncertainties in estimates of components of variance in multivariate ROC analysis.

Authors:  S V Beiden; R F Wagner; G Campbell; H P Chan
Journal:  Acad Radiol       Date:  2001-07       Impact factor: 3.173

3.  Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method.

Authors:  D D Dorfman; K S Berbaum; C E Metz
Journal:  Invest Radiol       Date:  1992-09       Impact factor: 6.016

4.  Observer studies involving detection and localization: modeling, analysis, and validation.

Authors:  Dev P Chakraborty; Kevin S Berbaum
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

5.  Gains in accuracy from replicated readings of diagnostic images: prediction and assessment in terms of ROC analysis.

Authors:  C E Metz; J H Shen
Journal:  Med Decis Making       Date:  1992 Jan-Mar       Impact factor: 2.583

6.  Neural networks for computer-aided diagnosis: detection of lung nodules in chest radiograms.

Authors:  Giuseppe Coppini; Stefano Diciotti; Massimo Falchini; Natale Villari; Guido Valli
Journal:  IEEE Trans Inf Technol Biomed       Date:  2003-12

7.  A technique optimization protocol and the potential for dose reduction in digital mammography.

Authors:  Nicole T Ranger; Joseph Y Lo; Ehsan Samei
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

8.  Analyzing a portion of the ROC curve.

Authors:  D K McClish
Journal:  Med Decis Making       Date:  1989 Jul-Sep       Impact factor: 2.583

Review 9.  Unified measurement of observer performance in detecting and localizing target objects on images.

Authors:  R G Swensson
Journal:  Med Phys       Date:  1996-10       Impact factor: 4.071

10.  A receiver operating characteristic partial area index for highly sensitive diagnostic tests.

Authors:  Y Jiang; C E Metz; R M Nishikawa
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

View more
  3 in total

1.  The impact of simulated motion blur on lesion detection performance in full-field digital mammography.

Authors:  Ahmed K Abdullah; Judith Kelly; John D Thompson; Claire E Mercer; Rob Aspin; Peter Hogg
Journal:  Br J Radiol       Date:  2017-06-16       Impact factor: 3.039

2.  ROC or FROC? It depends on the research question.

Authors:  Stephen L Hillis; Dev P Chakraborty; Colin G Orton
Journal:  Med Phys       Date:  2017-03-17       Impact factor: 4.071

Review 3.  Multi-reader multi-case studies using the area under the receiver operator characteristic curve as a measure of diagnostic accuracy: systematic review with a focus on quality of data reporting.

Authors:  Thaworn Dendumrongsup; Andrew A Plumb; Steve Halligan; Thomas R Fanshawe; Douglas G Altman; Susan Mallett
Journal:  PLoS One       Date:  2014-12-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.