Literature DB >> 23009187

Chemical resistance of disposable nitrile gloves exposed to simulated movement.

Robert N Phalen1, Weng Kee Wong.   

Abstract

Large discrepancies between laboratory permeation testing and field exposures have been reported, with indications that hand movement could account for a portion of these differences. This study evaluated the influence of simulated movement on chemical permeation of 30 different disposable nitrile glove products. Products were investigated out-of-box and with exposure to simulated whole-glove movement. Permeation testing was conducted using ethanol as a surrogate test chemical. A previously designed pneumatic system was used to simulate hand movement. No movement and movement tests were matched-paired to control for environmental conditions, as were statistical analyses. Permeation data were collected for a 30-min exposure period or until a breakthrough time (BT) and steady-state permeation rate (SSPR) could be determined. A third parameter, area under the curve at 30 min (AUC-30), was used to estimate potential worker exposure. With movement, a significant decrease in BT (p ≤ 0.05), ranging from 6-33%, was observed for 28 products. The average decrease in BT was 18% (p ≤ 0.001). With movement, a significant increase in SSPR (p ≤ 0.05), ranging from 1-78%, was observed with 25 products. The average increase in SSPR was 18% (p ≤ 0.001). Significant increases in AUC-30 (p ≤ 0.05), ranging from 23-277%, were also observed for all products where it could be calculated. On average, there was a 58% increase (p ≤ 0.001). The overall effect of movement on permeation through disposable nitrile gloves was significant. Simulated movement significantly shortened the BT, increased the SSPR, and increased the cumulative 30-min exposure up to three times. Product variability also accounted for large differences, up to 40 times, in permeation and cumulative exposure. Glove selection must take these factors into account. It cannot be assumed that all products will perform in a similar manner.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23009187      PMCID: PMC3495187          DOI: 10.1080/15459624.2012.723584

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  10 in total

Review 1.  A critique of assumptions about selecting chemical-resistant gloves: a case for workplace evaluation of glove efficacy.

Authors:  Thomas D Klingner; Mark F Boeniger
Journal:  Appl Occup Environ Hyg       Date:  2002-05

2.  Occupational exposure and dose over time: limitations of cumulative exposure.

Authors:  T J Smith
Journal:  Am J Ind Med       Date:  1992       Impact factor: 2.214

3.  Concepts of skin protection: considerations for the evaluation and terminology of the performance of skin protective equipment.

Authors:  Derk H Brouwer; Robert J Aitken; Reinhard Oppl; John W Cherrie
Journal:  J Occup Environ Hyg       Date:  2005-09       Impact factor: 2.155

4.  A moving robotic hand system for whole-glove permeation and penetration: captan and nitrile gloves.

Authors:  Robert Phalen; Shane Que Hee
Journal:  J Occup Environ Hyg       Date:  2008-04       Impact factor: 2.155

5.  Batch lot variability in permeation through nitrile gloves.

Authors:  J L Perkins; B Pool
Journal:  Am Ind Hyg Assoc J       Date:  1997-07

6.  A breakthrough time comparison of nitrile and neoprene glove materials produced by different glove manufacturers.

Authors:  R L Mickelsen; R C Hall
Journal:  Am Ind Hyg Assoc J       Date:  1987-11

7.  Integrity of disposable nitrile exam gloves exposed to simulated movement.

Authors:  Robert N Phalen; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2011-05       Impact factor: 2.155

8.  Environmental contamination and assessment of exposure to antineoplastic agents by determination of cyclophosphamide in urine of exposed pharmacy technicians: is skin absorption an important exposure route?

Authors:  P J Sessink; M C Van de Kerkhof; R B Anzion; J Noordhoek; R P Bos
Journal:  Arch Environ Health       Date:  1994 May-Jun

9.  Modeling the temperature dependence of N-methylpyrrolidone permeation through butyl- and natural-rubber gloves.

Authors:  E T Zellers; R Sulewski
Journal:  Am Ind Hyg Assoc J       Date:  1993-09

10.  Permeability of 13 different gloves to 13 cytotoxic agents under controlled dynamic conditions.

Authors:  Pierre E Wallemacq; Arnaud Capron; Roger Vanbinst; Eric Boeckmans; Jean Gillard; Bertrand Favier
Journal:  Am J Health Syst Pharm       Date:  2006-03-15       Impact factor: 2.637

  10 in total
  5 in total

1.  Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

Authors:  Robert N Phalen; Thi Le; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

Review 2.  Glove permeation of chemicals: The state of the art of current practice, Part 1: Basics and the permeation standards.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2019-11-04       Impact factor: 2.155

Review 3.  A review of HTM 01-05 through an environmentally sustainable lens.

Authors:  Brett Duane; Paul Ashley; Darshini Ramasubbu; Amarantha Fennell-Wells; Brian Maloney; Taylor McKerlie; John Crotty; Mark Johnstone; Sheryl Wilmott
Journal:  Br Dent J       Date:  2022-08-26       Impact factor: 2.727

Review 4.  Glove permeation of chemicals: The state of the art of current practice-Part 2. Research emphases on high boiling point compounds and simulating the donned glove environment.

Authors:  Sean Banaee; Shane S Que Hee
Journal:  J Occup Environ Hyg       Date:  2020-03-25       Impact factor: 2.155

5.  Hazardous substances in frequently used professional cleaning products.

Authors:  Fabian Melchior Gerster; David Vernez; Pascal Pierre Wild; Nancy Brenna Hopf
Journal:  Int J Occup Environ Health       Date:  2014 Jan-Mar
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.