Literature DB >> 22987158

Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study.

Wei Tian1, Yajun Liu, Shan Zheng, Yanwei Lv.   

Abstract

PURPOSE: Evaluate the accuracy of five different techniques for lower cervical pedicle screw placement.
METHODS: Forty human cadaveric cervical spines were equally divided into five groups, and each group had eight specimens. Pedicle screws with dia. 3.5 mm were used. Group 1 was blind screw placement without any assistance; Group 2-5 was assisted by the X-ray fluoroscopy, virtual fluoroscopy navigation system, CT-based navigation system, and Iso-C 3D navigation system, respectively. Thereafter, cortical integrity of each pedicle was evaluated by anatomic dissection of the specimens.
RESULTS: A total of 398 pedicle screws were inserted. In the Group 1-5, the average operation time per sample was 27 ± 3.0, 112 ± 10.3, 69 ± 6.4, 98 ± 11.0, and 91 ± 6.0 min, respectively. The outcome for excellent, fair and poor were 29 (36.3 %), 21 (26.2 %) and 30 (37.5 %) in Group 1; 35 (44.9 %), 29 (37.2 %) and 14 (17.9 %) in Group 2; 34 (42.5 %), 36 (45.0 %) and 10 (12.5 %) in Group 3; 70 (87.5 %), 10 (12.5 %) and 0 (0.0 %) in Group 4; 72 (90.0 %), 8 (10.0 %) and 0 (0.0 %) in Group 5.
CONCLUSIONS: Blind screw placement was surely unsafe. Lower cervical pedicle screw placement assisted by the CT-based navigation system or the Iso-C 3D navigation system significantly improved the accuracy compared to the fluoroscopy assistance and the virtual fluoroscopy navigation assistance.

Entities:  

Mesh:

Year:  2012        PMID: 22987158      PMCID: PMC3540299          DOI: 10.1007/s00586-012-2494-6

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  14 in total

1.  Pedicle screw placement accuracy: a meta-analysis.

Authors:  Victor Kosmopoulos; Constantin Schizas
Journal:  Spine (Phila Pa 1976)       Date:  2007-02-01       Impact factor: 3.468

2.  Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries.

Authors:  S Rajasekaran; S Vidyadhara; Perumal Ramesh; Ajoy P Shetty
Journal:  Spine (Phila Pa 1976)       Date:  2007-01-15       Impact factor: 3.468

3.  Biomechanical pullout strength and stability of the cervical artificial pedicle screw.

Authors:  Alison H Barnes; Johnny A Eguizabal; Frank L Acosta; Jeffrey C Lotz; Jenni M Buckley; Christopher P Ames
Journal:  Spine (Phila Pa 1976)       Date:  2009-01-01       Impact factor: 3.468

Review 4.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

5.  Radiation exposure from musculoskeletal computerized tomographic scans.

Authors:  Debdut Biswas; Jesse E Bible; Michael Bohan; Andrew K Simpson; Peter G Whang; Jonathan N Grauer
Journal:  J Bone Joint Surg Am       Date:  2009-08       Impact factor: 5.284

6.  Pedicle screw fixation in the cervical spine.

Authors:  Rongming Xu; Nabil A Ebraheim; Martin Skie
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2008-08

Review 7.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

8.  Cervical pedicle screw insertion using a computed tomography cutout technique.

Authors:  Hiroshi Miyamoto; Koki Uno
Journal:  J Neurosurg Spine       Date:  2009-12

9.  Posterior fixation and fusion of unstable Hangman's fracture by using intraoperative three-dimensional fluoroscopy-based navigation.

Authors:  Wei Tian; Chong Weng; Bo Liu; Qin Li; Lin Hu; Zhi-Yu Li; Ya-Jun Liu; Yu-Zhen Sun
Journal:  Eur Spine J       Date:  2011-11-23       Impact factor: 3.134

10.  Complications of pedicle screw fixation in reconstructive surgery of the cervical spine.

Authors:  K Abumi; Y Shono; M Ito; H Taneichi; Y Kotani; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  2000-04-15       Impact factor: 3.468

View more
  15 in total

1.  Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.

Authors:  Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein
Journal:  Eur Spine J       Date:  2016-01-25       Impact factor: 3.134

2.  Cervical pedicle screw instrumentation is more reliable with O-arm-based 3D navigation: analysis of cervical pedicle screw placement accuracy with O-arm-based 3D navigation.

Authors:  Sourabh Chachan; Hamid Rahmatullah Bin Abd Razak; Wee Lim Loo; John Carson Allen; Dinesh Shree Kumar
Journal:  Eur Spine J       Date:  2018-04-12       Impact factor: 3.134

3.  The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine.

Authors:  J Bredow; J Oppermann; B Kraus; P Schiller; G Schiffer; R Sobottke; P Eysel; T Koy
Journal:  Eur Spine J       Date:  2015-04-30       Impact factor: 3.134

4.  Accuracy and workflow of navigated spinal instrumentation with the mobile AIRO(®) CT scanner.

Authors:  Nils Hecht; Marije Kamphuis; Marcus Czabanka; Bernd Hamm; Susanne König; Johannes Woitzik; Michael Synowitz; Peter Vajkoczy
Journal:  Eur Spine J       Date:  2015-02-22       Impact factor: 3.134

5.  A novel technique of cervical pedicle screw placement with a pilot screw under the guidance of intraoperative 3D imaging from C-arm cone-beam CT without navigation for safe and accurate insertion.

Authors:  Masahiko Takahata; Katsuhisa Yamada; Iwata Akira; Tsutomu Endo; Hideki Sudo; Hidetoki Yokoyama; Norimasa Iwasaki
Journal:  Eur Spine J       Date:  2018-07-23       Impact factor: 3.134

6.  The intraoperative portable CT scanner-based spinal navigation: a viable option for instrumentation in the region of cervico-thoracic junction.

Authors:  Pavel Barsa; Robert Frőhlich; Miroslav Šercl; Pavel Buchvald; Petr Suchomel
Journal:  Eur Spine J       Date:  2016-03-17       Impact factor: 3.134

7.  Accuracy of pedicle screw insertion by AIRO® intraoperative CT in complex spinal deformity assessed by a new classification based on technical complexity of screw insertion.

Authors:  S Rajasekaran; Manindra Bhushan; Siddharth Aiyer; Rishi Kanna; Ajoy Prasad Shetty
Journal:  Eur Spine J       Date:  2018-01-09       Impact factor: 3.134

8.  Posterior internal fixation plus vertebral bone implantation under navigational aid for thoracolumbar fracture treatment.

Authors:  Wei Zhou; Weiqing Kong; Bizhen Zhao; Yishan Fu; Tao Zhang; Jianguang Xu
Journal:  Exp Ther Med       Date:  2013-04-29       Impact factor: 2.447

9.  CT morphometric analysis to determine the anatomical basis for the use of transpedicular screws during reconstruction and fixations of anterior cervical vertebrae.

Authors:  Chun Chen; Dike Ruan; Changfu Wu; Weidong Wu; Peidong Sun; Yuanzhi Zhang; Jigong Wu; Sheng Lu; Jun Ouyang
Journal:  PLoS One       Date:  2013-12-11       Impact factor: 3.240

10.  In vitro study of accuracy of subaxial cervical pedicle screw insertion using calipers based on the gravity line.

Authors:  Xiang Yao; Shiqing Liu
Journal:  PLoS One       Date:  2017-07-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.