Literature DB >> 10767809

Complications of pedicle screw fixation in reconstructive surgery of the cervical spine.

K Abumi1, Y Shono, M Ito, H Taneichi, Y Kotani, K Kaneda.   

Abstract

STUDY
DESIGN: Retrospective evaluation of complications in 180 consecutive patients with cervical disorders who had been treated by using pedicle screw fixation systems.
OBJECTIVES: To determine the risks associated with pedicle screw fixation in the cervical spine and to emphasize the importance of preoperative planning and surgical techniques in reducing the risks of this procedure. SUMMARY OF BACKGROUND DATA: Generally, pedicle screw fixation in the cervical spine has been considered too risky for the neurovascular structures. There have been several reports describing the complications of lateral mass screw-plate fixation. However, no studies have examined in detail the complications associated with cervical pedicle screw fixation.
METHODS: One hundred eighty patients who underwent cervical reconstructive surgery using cervical pedicle screw fixation were reviewed to clarify the complications associated with the pedicle screw fixation procedure. Cervical disorders were spinal injuries in 70 patients and nontraumatic lesions in 110 patients. Seven hundred twelve screws were inserted into the cervical pedicles, and the locations of 669 screws were radiologically evaluated.
RESULTS: Injury of the vertebral artery occurred in one patient. The bleeding was stopped by bone wax, and no neurologic complication developed after surgery. On computed tomographic (CT) scan, 45 screws (6.7%) were found to penetrate the pedicle, and 2 of 45 screws caused radiculopathy. Besides these three neurovascular complications directly attributed to screw insertion, radiculopathy caused by iatrogenic foraminal stenosis from excessive reduction of the translational deformity was observed in one patient.
CONCLUSIONS: The incidence of the clinically significant complications caused by pedicle screw insertion was low. Complications associated with cervical pedicle screw fixation can be minimized by sufficient preoperative imaging studies of the pedicles and strict control of screw insertion. Pedicle screw fixation is a useful procedure for reconstruction of the cervical spine in various kinds of disorders and can be performed safely.

Entities:  

Mesh:

Year:  2000        PMID: 10767809     DOI: 10.1097/00007632-200004150-00011

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  130 in total

1.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  The use of pedicle screw-rod system for the posterior fixation in cervico-thoracic junction.

Authors:  Wonik Cho; Ahmed Shawky Eid; Ung-Kyu Chang
Journal:  J Korean Neurosurg Soc       Date:  2010-07-31

3.  Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs.

Authors:  Bradley J Dunlap; Eldin E Karaikovic; Hyung-Soon Park; Mark J Sokolowski; Li-Qun Zhang
Journal:  Eur Spine J       Date:  2010-02-02       Impact factor: 3.134

4.  Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina.

Authors:  Katsuhiro Tofuku; Hiroaki Koga; Setsuro Komiya
Journal:  Eur Spine J       Date:  2011-08-10       Impact factor: 3.134

5.  Monitoring reduced scattering coefficient in pedicle screw insertion trajectory using near-infrared spectroscopy.

Authors:  Weitao Li; Yangyang Liu; Haixiang Sun; Yue Pan; Zhiyu Qian
Journal:  Med Biol Eng Comput       Date:  2015-12-22       Impact factor: 2.602

6.  The C7 pedicle as a superior fixation point in spinal stabilization for spinal metastatic disease.

Authors:  Harjot Thind; Andrew J Fabiano
Journal:  J Spine Surg       Date:  2018-03

Review 7.  An overview of blood-sparing techniques used in spine surgery during the perioperative period.

Authors:  Marek Szpalski; Robert Gunzburg; Bernard Sztern
Journal:  Eur Spine J       Date:  2004-06-15       Impact factor: 3.134

8.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

9.  Percutaneous, Navigated Minimally Invasive Posterior Cervical Pedicle Screw Fixation.

Authors:  Domagoj Coric; Vincent J Rossi; John Peloza; Paul K Kim; Tim E Adamson
Journal:  Int J Spine Surg       Date:  2020-10-29

10.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

View more