Aortic valve closure associated with HeartMate left ventricular device support: technical considerations and long-term results.

Robert M Adamson1, Walter P Dembitsky, Sam Baradarian, Joseph Chammas, Karen May-Newman, Suzanne Chillcott, Marcia Stahovich, Vicki McCalmont, Kristi Ortiz, Peter Hoagland, Brian Jaski.   

Abstract

BACKGROUND: Aortic valve integrity is crucial for optimal left ventricular assist device (LVAD) support. Pre-existing native aortic insufficiency, aortic valve incompetence acquired during support, as well as previously placed prosthetic aortic valves present unique problems for these patients.
METHODS: We reviewed and analyzed data for 28 patients who underwent left ventricular outflow tract closure associated with HeartMate I (n =12) and HeartMate II (n = 16) LVAD insertion or exchange. Indications for valve closure, surgical technique, LVAD function, survival rates and complications were retrospectively analyzed. Survival rates were compared with those of HeartMate LVAD patients (n = 104) who did not undergo aortic valve closure.
RESULTS: Indications for closure included native aortic valve insufficiency (10 patients), aortic valve deterioration after prolonged LVAD support (8 patients) and previously placed mechanical (9 patients) or bioprosthetic aortic prostheses (1 patient). There were 2 operative and 5 late deaths (mean 227 days post-operatively). Of the deaths, none were due to aortic valve closure. Actuarial survival was 78% at 1 year and 53% at 3 years, which was statistically better than for our patients with an intact aortic outflow (61% at 1 year, 45% at 3 years; p < 0.05). Five patients had transplants, 1 patient was successfully bridged to recovery, and 15 patients remain on LVAD support. No patient with outflow closure developed regurgitation, embolization or compromised LVAD support.
CONCLUSION: Outflow tract closure in LVAD-supported patients is safe, often necessary and well tolerated.
Copyright © 2011 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21256765     DOI: 10.1016/j.healun.2010.11.007

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  17 in total

1.  Replacement of the aortic valve with a bioprosthesis at the time of continuous flow ventricular assist device implantation for preexisting aortic valve dysfunction.

Authors:  Brian Lima; Themistokles Chamogeorgakis; Maria Mountis; Gonzalo V Gonzalez-Stawinski
Journal:  Proc (Bayl Univ Med Cent)       Date:  2015-10

Review 2.  Simultaneous procedures during left ventricular assist device implantation: is less always more?

Authors:  Nikhil Jaik; Robert S D Higgins; Bryan A Whitson
Journal:  Curr Heart Fail Rep       Date:  2014-03

Review 3.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

4.  Shear stress and blood trauma under constant and pulse-modulated speed CF-VAD operations: CFD analysis of the HVAD.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Michael A Sobieski; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Biol Eng Comput       Date:  2018-11-08       Impact factor: 2.602

5.  Daily transient discontinuation of extracorporeal LVAD to prevent thromboembolism of mechanical aortic valve prosthesis.

Authors:  Takamichi Inoue; Tadashi Kitamura; Shinzo Torii; Mitsuhiro Hirata; Toshiaki Mishima; Koichi Sughimoto; Hirotoki Ohkubo; Kensuke Kobayashi; Mamika Motokawa; Miyuki Shibata; Takuya Matsushiro; Yuta Tsuchida; Yurie Miyata; Minoru Ono; Kagami Miyaji
Journal:  J Artif Organs       Date:  2017-05-09       Impact factor: 1.731

Review 6.  Mechanical circulatory support: devices, outcomes and complications.

Authors:  Carmelo A Milano; Alan A Simeone
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

Review 7.  Current practice in patient selecting for long-term mechanical circulatory support.

Authors:  M S Halbreiner; E Soltesz; R Starling; N Moazami
Journal:  Curr Heart Fail Rep       Date:  2015-04

Review 8.  Clinical management for complications related to implantable LVAD use.

Authors:  Koichi Toda; Yoshiki Sawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-11-05

9.  Aortic valve closure for rapidly deteriorated aortic insufficiency after continuous flow left ventricular assist device implantation.

Authors:  Tomoyuki Fujita; Junjiro Kobayashi; Hiroki Hata; Osamu Seguchi; Takuma Sato; Masanobu Yanase; Yoshihiro Murata; Haruki Sunami; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2012-09-18       Impact factor: 1.731

Review 10.  Chronic outpatient management of patients with a left ventricular assist device.

Authors:  Elisa M Smith; Jennifer Franzwa
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.