Literature DB >> 19059105

Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device.

James O Mudd1, Jonathan D Cuda, Marc Halushka, Karl A Soderlund, John V Conte, Stuart D Russell.   

Abstract

BACKGROUND: Left ventricular assist devices (LVADs) are an important therapy for selected individuals with advanced heart failure unable to wait for a suitable donor for transplantation. Pulsatile LVADs are associated with commissural fusion of the aortic valve, yet little is known about this association with newer generation continuous axial flow LVADs.
METHODS: We retrospectively reviewed pathologic samples from 9 patients enrolled in the HeartMate II Bridge to Transplantation Trial. Echocardiograms at 1, 6 and 12 months after device placement were evaluated for aortic valve opening and aortic insufficiency. At the time of transplantation, explanted hearts were examined for gross pathologic valvular abnormalities and histologic analysis.
RESULTS: All but 1 explant had evidence of commissural fusion of the native aortic valve leaflets. Over time there was a decreasing prevalence of aortic valve opening and an increasing prevalence of mild to moderate aortic insufficiency independent of pump speed. All patients had improvements in their functional status and were successfully bridged to orthotopic heart transplantation.
CONCLUSIONS: Commissural fusion of the native aortic valve leaflets occurs frequently with an increasing prevalence of aortic insufficiency during continuous flow LVAD support. With the potential broader use of non-pulsatile LVADs and the prospect of using LVADs as means to assist in myocardial recovery, special attention should be given to evaluating aortic valve function during LVAD support.

Entities:  

Mesh:

Year:  2008        PMID: 19059105     DOI: 10.1016/j.healun.2008.05.029

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  29 in total

1.  Analysis of aortic valve commissural fusion after support with continuous-flow left ventricular assist device.

Authors:  Jerson R Martina; Marguerite E I Schipper; Nicolaas de Jonge; Faiz Ramjankhan; Roel A de Weger; Jaap R Lahpor; Aryan Vink
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-06-24

Review 2.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

Review 3.  Impact of adverse events on ventricular assist device outcomes.

Authors:  Aleksandar Adzic; Snehal R Patel; Simon Maybaum
Journal:  Curr Heart Fail Rep       Date:  2013-03

4.  Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved?

Authors:  Tohid Pirbodaghi; Siavash Asgari; Chris Cotter; Kevin Bourque
Journal:  Heart Fail Rev       Date:  2014-03       Impact factor: 4.214

5.  Impact of LVAD Implantation Site on Ventricular Blood Stagnation.

Authors:  Anthony R Prisco; Alberto Aliseda; Jennifer A Beckman; Nahush A Mokadam; Claudius Mahr; Guilherme J M Garcia
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

Review 6.  Mechanical circulatory support: devices, outcomes and complications.

Authors:  Carmelo A Milano; Alan A Simeone
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

7.  The development of aortic insufficiency in left ventricular assist device-supported patients.

Authors:  Jennifer Cowger; Francis D Pagani; Jonathan W Haft; Matthew A Romano; Keith D Aaronson; Theodore J Kolias
Journal:  Circ Heart Fail       Date:  2010-08-25       Impact factor: 8.790

8.  Preservation of native aortic valve flow and full hemodynamic support with the TORVAD using a computational model of the cardiovascular system.

Authors:  Jeffrey R Gohean; Mitchell J George; Kay-Won Chang; Erik R Larson; Thomas D Pate; Mark Kurusz; Raul G Longoria; Richard W Smalling
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

9.  Living Without a Pulse: The Vascular Implications of Continuous-Flow Left Ventricular Assist Devices.

Authors:  Suneet N Purohit; William K Cornwell; Jay D Pal; JoAnn Lindenfeld; Amrut V Ambardekar
Journal:  Circ Heart Fail       Date:  2018-06       Impact factor: 8.790

10.  Development of a novel drive mode to prevent aortic insufficiency during continuous-flow LVAD support by synchronizing rotational speed with heartbeat.

Authors:  Yuichiro Kishimoto; Yoshiaki Takewa; Mamoru Arakawa; Akihide Umeki; Masahiko Ando; Takashi Nishimura; Yutaka Fujii; Toshihide Mizuno; Motonobu Nishimura; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-23       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.