Literature DB >> 22981854

AdaptiveIterative Dose Reduction in coronary CT angiography using 320-row CT: assessment of radiation dose reduction and image quality.

Nobuo Tomizawa1, Takeshi Nojo, Masaaki Akahane, Rumiko Torigoe, Shigeru Kiryu, Kuni Ohtomo.   

Abstract

BACKGROUND: Several methods have been developed to reduce the radiation dose in coronary computed tomography angiography (CTA).
OBJECTIVE: The objective of our study was to evaluate the effects of Adaptive Iterative Dose Reduction (AIDR) on objective and subjective image quality as well as the radiation dose, compared with conventional filtered back projection (FBP), in coronary CTA.
METHODS: We retrospectively reviewed 100 consecutive patients who underwent coronary CTA. In the first 50 patients, a higher tube current was used, and images were reconstructed with FBP. In the last 50 patients, a lower tube current was used, and images were reconstructed with AIDR. Subjective and objective image quality (noise, signal-to-noise ratio, contrast-to-noise ratio) were assessed.
RESULTS: The median radiation dose of the AIDR group was 22% lower than that of the FBP group (4.2 vs 5.4 mSv; P = 0.0001). No significant difference was found in subjective image quality, noise, signal-to-noise ratio, or contrast-to-noise ratio between the 2 groups.
CONCLUSION: AIDR reduced the tube current which resulted in reduction of radiation dose in coronary CTA while maintaining subjective and objective image quality compared with coronary CTA reconstructed with FBP.
Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22981854     DOI: 10.1016/j.jcct.2012.02.009

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  25 in total

Review 1.  Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis.

Authors:  Annemarie M Den Harder; Martin J Willemink; Quirina M B De Ruiter; Pim A De Jong; Arnold M R Schilham; Gabriel P Krestin; Tim Leiner; Ricardo P J Budde
Journal:  Br J Radiol       Date:  2015-11-12       Impact factor: 3.039

2.  Detection of pure ground-glass nodules in the lung by low-dose multi-detector computed tomography, with use of an iterative reconstruction method: a comparison with conventional image reconstruction by the filtered back-projection method.

Authors:  Shiho Akashita; Yasuhiko Tachibana; Kentaro Sakamaki; Keiji Sogawa; Tomio Inoue
Journal:  Jpn J Radiol       Date:  2015-01-01       Impact factor: 2.374

3.  Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.

Authors:  Fuminari Tatsugami; Toru Higaki; Wataru Fukumoto; Yoko Kaichi; Chikako Fujioka; Masao Kiguchi; Hideya Yamamoto; Yasuki Kihara; Kazuo Awai
Journal:  Int J Cardiovasc Imaging       Date:  2015-03-10       Impact factor: 2.357

4.  Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study.

Authors:  S Feger; A Shaban; S Lukas; C Kendziorra; M Rief; E Zimmermann; M Dewey
Journal:  Int J Cardiovasc Imaging       Date:  2016-11-10       Impact factor: 2.357

5.  Neointimal formation after carotid artery stenting: phantom and clinical evaluation of model-based iterative reconstruction (MBIR).

Authors:  Kazushi Yokomachi; Fuminari Tatsugami; Toru Higaki; Shinji Kume; Shigeyuki Sakamoto; Takahito Okazaki; Kaoru Kurisu; Yuko Nakamura; Yasutaka Baba; Makoto Iida; Kazuo Awai
Journal:  Eur Radiol       Date:  2018-06-22       Impact factor: 5.315

6.  Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner.

Authors:  Nobuo Tomizawa; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-17       Impact factor: 2.357

7.  Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study.

Authors:  K W Doo; E-Y Kang; H S Yong; O H Woo; K Y Lee; Y-W Oh
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

8.  Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT.

Authors:  Nobuo Tomizawa; Shigeaki Kanno; Eriko Maeda; Masaaki Akahane; Rumiko Torigoe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2014-04-28       Impact factor: 2.374

9.  Effect of the forward-projected model-based iterative reconstruction solution algorithm on image quality and radiation dose in pediatric cardiac computed tomography.

Authors:  Yukako Nishiyama; Keiji Tada; Yuichi Nishiyama; Hiroshi Mori; Mitsunari Maruyama; Takashi Katsube; Nobuko Yamamoto; Hidekazu Kanayama; Yasushi Yamamoto; Hajime Kitagaki
Journal:  Pediatr Radiol       Date:  2016-08-16

10.  Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis.

Authors:  Ernesto Di Cesare; Antonio Gennarelli; Alessandra Di Sibio; Valentina Felli; Alessandra Splendiani; Giovanni Luca Gravina; Antonio Barile; Carlo Masciocchi
Journal:  Radiol Med       Date:  2014-02-20       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.