Literature DB >> 26562096

Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis.

Annemarie M Den Harder1, Martin J Willemink1, Quirina M B De Ruiter2, Pim A De Jong1, Arnold M R Schilham1, Gabriel P Krestin3, Tim Leiner1, Ricardo P J Budde3.   

Abstract

OBJECTIVE: To investigate the achievable radiation dose reduction for coronary CT angiography (CCTA) with iterative reconstruction (IR) in adults and the effects on image quality.
METHODS: PubMed and EMBASE were searched, and original articles concerning IR for CCTA in adults using prospective electrocardiogram triggering were included. Primary outcome was the effective dose using filtered back projection (FBP) and IR. Secondary outcome was the effect of IR on objective and subjective image quality.
RESULTS: The search yielded 1616 unique articles, of which 10 studies (1042 patients) were included. The pooled routine effective dose with FBP was 4.2 mSv [95% confidence interval (CI) 3.5-5.0]. A dose reduction of 48% to a pooled effective dose of 2.2 mSv (95% CI 1.3-3.1) using IR was reported. Noise, contrast-to-noise ratio and subjective image quality were equal or improved in all but one study, whereas signal-to-noise ratio was decreased in two studies with IR at reduced dose.
CONCLUSION: IR allows for CCTA acquisition with an effective dose of 2.2 mSv with preserved objective and subjective image quality.

Entities:  

Mesh:

Year:  2015        PMID: 26562096      PMCID: PMC4985187          DOI: 10.1259/bjr.20150068

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  The CT-STAT (Coronary Computed Tomographic Angiography for Systematic Triage of Acute Chest Pain Patients to Treatment) trial.

Authors:  James A Goldstein; Kavitha M Chinnaiyan; Aiden Abidov; Stephan Achenbach; Daniel S Berman; Sean W Hayes; Udo Hoffmann; John R Lesser; Issam A Mikati; Brian J O'Neil; Leslee J Shaw; Michael Y H Shen; Uma S Valeti; Gilbert L Raff
Journal:  J Am Coll Cardiol       Date:  2011-09-27       Impact factor: 24.094

Review 2.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

3.  Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection.

Authors:  Rui Wang; U Joseph Schoepf; Runze Wu; Ryan P Reddy; Chuanchen Zhang; Wei Yu; Yi Liu; Zhaoqi Zhang
Journal:  Eur J Radiol       Date:  2012-05-10       Impact factor: 3.528

4.  Iterative image reconstruction techniques: Applications for cardiac CT.

Authors:  Matthias Renker; Ashok Ramachandra; U Joseph Schoepf; Rainer Raupach; Paul Apfaltrer; Garrett W Rowe; Sebastian Vogt; Thomas G Flohr; J Matthias Kerl; Ralf W Bauer; Christian Fink; Thomas Henzler
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-05-25

5.  AdaptiveIterative Dose Reduction in coronary CT angiography using 320-row CT: assessment of radiation dose reduction and image quality.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-08-16

6.  Coronary computed tomography and triple rule out CT in patients with acute chest pain and an intermediate cardiac risk profile. Part 1: impact on patient management.

Authors:  Joachim Gruettner; Christian Fink; Thomas Walter; Mathias Meyer; Paul Apfaltrer; U Joseph Schoepf; Joachim Saur; Tim Sueselbeck; Dominik Traunwieser; Richard Takx; Stefan Kralev; Martin Borggrefe; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur J Radiol       Date:  2012-06-29       Impact factor: 3.528

7.  ART: mathematics and applications. A report on the mathematical foundations and on the applicability to real data of the algebraic reconstruction techniques.

Authors:  G T Herman; A Lent; S W Rowland
Journal:  J Theor Biol       Date:  1973-11-05       Impact factor: 2.691

Review 8.  Cardiac computed tomography technology and dose-reduction strategies.

Authors:  James P Earls; Jonathon Leipsic
Journal:  Radiol Clin North Am       Date:  2010-06-11       Impact factor: 2.303

9.  The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT.

Authors:  Yang Hou; Shu Xu; Wenli Guo; Mani Vembar; Qiyong Guo
Journal:  Eur J Radiol       Date:  2012-10-01       Impact factor: 3.528

10.  Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.

Authors:  Wei-Hua Yin; Bin Lu; Nan Li; Lei Han; Zhi-Hui Hou; Run-Ze Wu; Yong-Jian Wu; Hong-Xia Niu; Shi-Liang Jiang; Aleksander W Krazinski; Ullrich Ebersberger; Felix G Meinel; U Joseph Schoepf
Journal:  JACC Cardiovasc Imaging       Date:  2013-10-23
View more
  19 in total

1.  The usefulness of full-iterative reconstruction algorithm for the visualization of cystic artery on CT angiography.

Authors:  Toshihiko Hamamura; Yoshiko Hayashida; Yohei Takeshita; Koichiro Sugimoto; Issei Ueda; Koichiro Futatsuya; Shingo Kakeda; Takatoshi Aoki; Yukunori Korogi
Journal:  Jpn J Radiol       Date:  2019-04-30       Impact factor: 2.374

2.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

Review 3.  Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.

Authors:  Sock Keow Tan; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Kwan Hoong Ng; Yang Faridah Abdul Aziz; Kok Han Chee; Zhonghua Sun
Journal:  Br J Radiol       Date:  2018-03-29       Impact factor: 3.039

Review 4.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

5.  Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique.

Authors:  Jack W Lambert; Yuxin Sun; Karen G Ordovas; Robert G Gould; Sizhe Wang; Benjamin M Yeh
Journal:  J Comput Assist Tomogr       Date:  2018 May/Jun       Impact factor: 1.826

Review 6.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

Review 7.  Multimodality cardiac imaging in the 21st century: evolution, advances and future opportunities for innovation.

Authors:  Melissa A Daubert; Tina Tailor; Olga James; Leslee J Shaw; Pamela S Douglas; Lynne Koweek
Journal:  Br J Radiol       Date:  2020-11-25       Impact factor: 3.039

8.  Effectiveness of automatic tube potential selection with tube current modulation in coronary CT angiography for obese patients: Comparison with a body mass index-based protocol using the propensity score matching method.

Authors:  Hong Seon Lee; Young Joo Suh; Kyunghwa Han; Jin Young Kim; Suyon Chang; Dong Jin Im; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Young Jin Kim; Byoung Wook Choi
Journal:  PLoS One       Date:  2018-01-05       Impact factor: 3.240

Review 9.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

10.  High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium.

Authors:  Ruiqi Feng; Jiajie Tong; Xiaofei Liu; Yu Zhao; Liang Zhang
Journal:  Korean J Radiol       Date:  2017-07-17       Impact factor: 3.500

View more