Literature DB >> 22980510

Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels.

Michelle J Alfa1, Iram Fatima, Nancy Olson.   

Abstract

BACKGROUND: Compliance with cleaning of flexible endoscope channels cannot be verified using visual inspection. Adenosine triphosphate (ATP) has been suggested as a possible rapid cleaning monitor for flexible endoscope channels. There have not been published validation studies to specify the level of ATP that indicates inadequate cleaning has been achieved.
OBJECTIVE: The objective of this study was to validate the Clean-Trace (3M Inc, St. Paul, MN) ATP water test method for monitoring manual cleaning of flexible endoscopes.
METHODS: This was a simulated use study using a duodenoscope as the test device. Artificial test soil containing 10(6) colony-forming units of Pseudomonas aeruginosa and Enterococcus faecalis was used to perfuse all channels. The flush sample method for the suction-biopsy (L1) or air-water channel (L2) using 40 and 20 mLs sterile reverse osmosis water, respectively, was validated. Residuals of ATP, protein, hemoglobin, and bioburden were quantitated from channel samples taken from uncleaned, partially cleaned, and fully cleaned duodenoscopes. The benchmarks for clean were as follows: <6.4 μg/cm(2) protein, <2.2 μg/cm(2) hemoglobin, and <4-log10 colony-forming units/cm(2) bioburden.
RESULTS: The average ATP in clean channel samples was 27.7 RLUs and 154 RLUs for L1 and L2, respectively (<200 RLUs for all channels). The average protein, hemoglobin, and bioburden benchmarks were achieved if <200 RLUs were detected. If the channel sample was >200 RLUs, the residual organic and bioburden levels would exceed the acceptable benchmarks.
CONCLUSION: Our data validated that flexible endoscopes that have complete manual cleaning will have <200 RLUs by the Clean-Trace ATP test.
Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22980510     DOI: 10.1016/j.ajic.2012.03.018

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  17 in total

1.  Surface contamination in the operating room: use of adenosine triphosphate monitoring.

Authors:  Alex Ramirez; Sanjay Mohan; Rebecca Miller; Dmitry Tumin; Joshua C Uffman; Joseph D Tobias
Journal:  J Anesth       Date:  2018-12-11       Impact factor: 2.078

Review 2.  Duodenoscope-Associated Infections: Update on an Emerging Problem.

Authors:  M Rubayat Rahman; Abhilash Perisetti; Roxana Coman; Pardeep Bansal; Rajiv Chhabra; Hemant Goyal
Journal:  Dig Dis Sci       Date:  2018-12-19       Impact factor: 3.199

Review 3.  Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

Authors:  Günter Kampf; Patricia M Fliss; Heike Martiny
Journal:  World J Gastrointest Endosc       Date:  2014-09-16

4.  Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video).

Authors:  Monique T Barakat; Mohit Girotra; Robert J Huang; Subhas Banerjee
Journal:  Gastrointest Endosc       Date:  2018-02-06       Impact factor: 9.427

Review 5.  Current Practice of Duodenoscope Reprocessing.

Authors:  Stephen Kim; V Raman Muthusamy
Journal:  Curr Gastroenterol Rep       Date:  2016-10

Review 6.  Duodenoscope-associated infections: a review.

Authors:  Gheorghe G Balan; Catalin Victor Sfarti; Stefan Andrei Chiriac; Carol Stanciu; Anca Trifan
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-09-03       Impact factor: 3.267

7.  Adenosine triphosphate bioluminescence for bacteriologic surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes.

Authors:  Saurabh Sethi; Robert J Huang; Monique T Barakat; Niaz Banaei; Shai Friedland; Subhas Banerjee
Journal:  Gastrointest Endosc       Date:  2016-11-03       Impact factor: 9.427

8.  Efficacy of a novel channel-cleaning ball brush for endoscope reprocessing: a randomized controlled trial.

Authors:  Kwang Hyun Chung; Jeong Don Chae; Wonho Choe; Hyo Young Lee; Il Hwan Oh; Byoung Kwan Son
Journal:  Clin Endosc       Date:  2022-08-02

Review 9.  Gastrointestinal Endoscopy-Associated Infections: Update on an Emerging Issue.

Authors:  Anasua Deb; Abhilash Perisetti; Hemant Goyal; Mark M Aloysius; Sonali Sachdeva; Dushyant Dahiya; Neil Sharma; Nirav Thosani
Journal:  Dig Dis Sci       Date:  2022-03-09       Impact factor: 3.487

10.  Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels.

Authors:  Michelle J Alfa; Nancy Olson
Journal:  BMC Res Notes       Date:  2016-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.