Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method.

Xun Jia1, Zhen Tian, Yifei Lou, Jan-Jakob Sonke, Steve B Jiang.   

Abstract

PURPOSE: Four-dimensional cone beam computed tomography (4D-CBCT) has been developed to provide respiratory phase-resolved volumetric imaging in image guided radiation therapy. Conventionally, it is reconstructed by first sorting the x-ray projections into multiple respiratory phase bins according to a breathing signal extracted either from the projection images or some external surrogates, and then reconstructing a 3D CBCT image in each phase bin independently using FDK algorithm. This method requires adequate number of projections for each phase, which can be achieved using a low gantry rotation or multiple gantry rotations. Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. 4D-CBCT images at different breathing phases share a lot of redundant information, because they represent the same anatomy captured at slightly different temporal points. Taking this redundancy along the temporal dimension into account can in principle facilitate the reconstruction in the situation of inadequate number of projection images. In this work, the authors propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method.
METHODS: The authors define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms implementation on GPU is designed to avoid redundant and uncoalesced memory access, in order to ensure a high computational efficiency. Our algorithms have been tested on a digital NURBS-based cardiac-torso phantom and a clinical patient case.
RESULTS: The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56-3.13 and our enhancement method increases the CNR by 2.75-3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is 509-683 s for the reconstruction algorithm and 524-540 s for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card.
CONCLUSIONS: By innovatively taking the temporal redundancy among 4D-CBCT images into consideration, the proposed algorithms can produce high quality 4D-CBCT images with much less streak artifacts than the FDK results, in the situation of inadequate number of projections.

Entities:  

Mesh:

Year:  2012        PMID: 22957625      PMCID: PMC3436920          DOI: 10.1118/1.4745559

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Four-dimensional cone-beam computed tomography using an on-board imager.

Authors:  Tianfang Li; Lei Xing; Peter Munro; Christopher McGuinness; Ming Chao; Yong Yang; Bill Loo; Albert Koong
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

2.  Fast non local means denoising for 3D MR images.

Authors:  Pierrick Coupé; Pierre Yger; Christian Barillot
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

3.  Linac-integrated 4D cone beam CT: first experimental results.

Authors:  Lars Dietrich; Siri Jetter; Thomas Tücking; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

4.  GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration.

Authors:  G C Sharp; N Kandasamy; H Singh; M Folkert
Journal:  Phys Med Biol       Date:  2007-09-10       Impact factor: 3.609

5.  High performance computing for deformable image registration: towards a new paradigm in adaptive radiotherapy.

Authors:  Sanjiv S Samant; Junyi Xia; Pinar Muyan-Ozcelik; John D Owens
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  Fast convolution-superposition dose calculation on graphics hardware.

Authors:  Sami Hissoiny; Benoît Ozell; Philippe Després
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Enhanced 4D cone-beam CT with inter-phase motion model.

Authors:  Tianfang Li; Albert Koong; Lei Xing
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

8.  Four-dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling.

Authors:  Jun Lu; Thomas M Guerrero; Peter Munro; Andrew Jeung; Pai-Chun M Chi; Peter Balter; X Ronald Zhu; Radhe Mohan; Tinsu Pan
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

9.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

10.  Streaking artifacts reduction in four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Joseph Zambelli; Ranjini Tolakanahalli; Brian Nett; Peter Munro; Joshua Star-Lack; Bhudatt Paliwal; Guang-Hong Chen
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more
  33 in total

1.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

3.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

4.  A method for volumetric imaging in radiotherapy using single x-ray projection.

Authors:  Yuan Xu; Hao Yan; Luo Ouyang; Jing Wang; Linghong Zhou; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

5.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization. Part II: An adaptive approach.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; Yan Liu; Hao Han; Hongbing Lu; William Moore; Zhengrong Liang
Journal:  Comput Med Imaging Graph       Date:  2015-03-06       Impact factor: 4.790

6.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections.

Authors:  You Zhang; Fang-Fang Yin; Tinsu Pan; Irina Vergalasova; Lei Ren
Journal:  Radiother Oncol       Date:  2015-03-26       Impact factor: 6.280

Review 7.  Patch-based models and algorithms for image processing: a review of the basic principles and methods, and their application in computed tomography.

Authors:  Davood Karimi; Rabab K Ward
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-10       Impact factor: 2.924

8.  Statistical iterative reconstruction using adaptive fractional order regularization.

Authors:  Yi Zhang; Yan Wang; Weihua Zhang; Feng Lin; Yifei Pu; Jiliu Zhou
Journal:  Biomed Opt Express       Date:  2016-02-24       Impact factor: 3.732

9.  Evaluating the four-dimensional cone beam computed tomography with varying gantry rotation speed.

Authors:  S A Yoganathan; K J Maria Das; Shajahan Mohamed Ali; Arpita Agarwal; Surendra P Mishra; Shaleen Kumar
Journal:  Br J Radiol       Date:  2016-02-26       Impact factor: 3.039

10.  Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-principle study.

Authors:  Jian-Feng Cai; Xun Jia; Hao Gao; Steve B Jiang; Zuowei Shen; Hongkai Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-04-21       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.