Literature DB >> 25795593

Statistical image reconstruction for low-dose CT using nonlocal means-based regularization. Part II: An adaptive approach.

Hao Zhang1, Jianhua Ma2, Jing Wang3, Yan Liu4, Hao Han4, Hongbing Lu5, William Moore4, Zhengrong Liang6.   

Abstract

To reduce radiation dose in X-ray computed tomography (CT) imaging, one common strategy is to lower the tube current and exposure time settings during projection data acquisition. However, this strategy would inevitably increase the projection data noise, and the resulting image by the conventional filtered back-projection (FBP) method may suffer from excessive noise and streak artifacts. The well-known edge-preserving nonlocal means (NLM) filtering can reduce the noise-induced artifacts in the FBP reconstructed image, but it sometimes cannot completely eliminate the artifacts, especially under the very low-dose circumstance when the image is severely degraded. Instead of taking NLM filtering, we proposed a NLM-regularized statistical image reconstruction scheme, which can effectively suppress the noise-induced artifacts and significantly improve the reconstructed image quality. From our previous investigation on NLM-based strategy, we noted that using a spatially invariant filtering parameter in the regularization was rarely optimal for the entire field of view (FOV). Therefore, in this study we developed a novel strategy for designing spatially variant filtering parameters which are adaptive to the local characteristics of the image to be reconstructed. This adaptive NLM-regularized statistical image reconstruction method was evaluated with low-contrast phantoms and clinical patient data to show (1) the necessity in introducing the spatial adaptivity and (2) the efficacy of the adaptivity in achieving superiority in reconstructing CT images from low-dose acquisitions.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adaptive nonlocal means; Low-dose; Statistical image reconstruction; X-ray CT

Mesh:

Year:  2015        PMID: 25795593      PMCID: PMC4450134          DOI: 10.1016/j.compmedimag.2015.02.008

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  28 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

3.  An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.

Authors:  P Coupe; P Yger; S Prima; P Hellier; C Kervrann; C Barillot
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

4.  Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.

Authors:  Joshua D Evans; David G Politte; Bruce R Whiting; Joseph A O'Sullivan; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

5.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Low-dose X-ray CT reconstruction via dictionary learning.

Authors:  Qiong Xu; Hengyong Yu; Xuanqin Mou; Lei Zhang; Jiang Hsieh; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2012-04-20       Impact factor: 10.048

7.  Low-dose 4DCT reconstruction via temporal nonlocal means.

Authors:  Zhen Tian; Xun Jia; Bin Dong; Yifei Lou; Steve B Jiang
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

8.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

9.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; Yan Liu; Hongbing Lu; Zhengrong Liang
Journal:  Comput Med Imaging Graph       Date:  2014-05-14       Impact factor: 4.790

10.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

View more
  8 in total

Review 1.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

2.  Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network.

Authors:  Xin Yi; Paul Babyn
Journal:  J Digit Imaging       Date:  2018-10       Impact factor: 4.056

Review 3.  Applications of nonlocal means algorithm in low-dose X-ray CT image processing and reconstruction: A review.

Authors:  Hao Zhang; Dong Zeng; Hua Zhang; Jing Wang; Zhengrong Liang; Jianhua Ma
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

4.  Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; William Moore; Zhengrong Liang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

5.  Nonlocal low-rank and sparse matrix decomposition for spectral CT reconstruction.

Authors:  Shanzhou Niu; Gaohang Yu; Jianhua Ma; Jing Wang
Journal:  Inverse Probl       Date:  2018-01-10       Impact factor: 2.407

6.  MULTI-ENERGY CONE-BEAM CT RECONSTRUCTION WITH A SPATIAL SPECTRAL NONLOCAL MEANS ALGORITHM.

Authors:  Bin Li; Chenyang Shen; Yujie Chi; Ming Yang; Yifei Lou; Linghong Zhou; Xun Jia
Journal:  SIAM J Imaging Sci       Date:  2018-05-08       Impact factor: 2.867

7.  LCPR-Net: low-count PET image reconstruction using the domain transform and cycle-consistent generative adversarial networks.

Authors:  Hengzhi Xue; Qiyang Zhang; Sijuan Zou; Weiguang Zhang; Chao Zhou; Changjun Tie; Qian Wan; Yueyang Teng; Yongchang Li; Dong Liang; Xin Liu; Yongfeng Yang; Hairong Zheng; Xiaohua Zhu; Zhanli Hu
Journal:  Quant Imaging Med Surg       Date:  2021-02

8.  Prior-image-based CT reconstruction using attenuation-mismatched priors.

Authors:  Hao Zhang; Dante Capaldi; Dong Zeng; Jianhua Ma; Lei Xing
Journal:  Phys Med Biol       Date:  2021-03-17       Impact factor: 3.609

  8 in total