Literature DB >> 17089847

Four-dimensional cone-beam computed tomography using an on-board imager.

Tianfang Li1, Lei Xing, Peter Munro, Christopher McGuinness, Ming Chao, Yong Yang, Bill Loo, Albert Koong.   

Abstract

On-board cone-beam computed tomography (CBCT) has recently become available to provide volumetric information of a patient in the treatment position, and holds promises for improved target localization and irradiation dose verification. The design of currently available on-board CBCT, however, is far from optimal. Its quality is adversely influenced by many factors, such as scatter, beam hardening, and intra-scanning organ motion. In this work we quantitatively study the influence of organ motion on CBCT imaging and investigate a strategy to acquire high quality phase-resolved [four-dimensional (4D)] CBCT images based on phase binning of the CBCT projection data. An efficient and robust method for binning CBCT data according to the patient's respiratory phase derived in the projection space was developed. The phase-binned projections were reconstructed using the conventional Feldkamp algorithm to yield 4D CBCT images. Both phantom and patient studies were carried out to validate the technique and to optimize the 4D CBCT data acquisition protocol. Several factors that are important to the clinical implementation of the technique, such as the image quality, scanning time, number of projections, and radiation dose, were analyzed for various scanning schemes. The general references drawn from this study are: (i) reliable phase binning of CBCT projections is accomplishable with the aid of external or internal marker and simple analysis of its trace in the projection space, and (ii) artifact-free 4D CBCT images can be obtained without increasing the patient radiation dose as compared to the current 3D CBCT scan.

Entities:  

Mesh:

Year:  2006        PMID: 17089847     DOI: 10.1118/1.2349692

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  58 in total

1.  4D Cone-beam CT reconstruction using a motion model based on principal component analysis.

Authors:  David Staub; Alen Docef; Robert S Brock; Constantin Vaman; Martin J Murphy
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  In-treatment 4D cone-beam CT with image-based respiratory phase recognition.

Authors:  Satoshi Kida; Yoshitaka Masutani; Hideomi Yamashita; Toshikazu Imae; Taeko Matsuura; Naoya Saotome; Kuni Ohtomo; Keiichi Nakagawa; Akihiro Haga
Journal:  Radiol Phys Technol       Date:  2012-02-25

3.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

4.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Iterative image reconstruction for CBCT using edge-preserving prior.

Authors:  Jing Wang; Tianfang Li; Lei Xing
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Quality and accuracy of cone beam computed tomography gated by active breathing control.

Authors:  Bria P Thompson; Geoffrey D Hugo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer.

Authors:  J P Santoro; J McNamara; E Yorke; H Pham; A Rimner; K E Rosenzweig; G S Mageras
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-principle study.

Authors:  Jian-Feng Cai; Xun Jia; Hao Gao; Steve B Jiang; Zuowei Shen; Hongkai Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-04-21       Impact factor: 10.048

9.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.