Literature DB >> 22899130

Synthetic-focusing strategies for real-time annular-array imaging.

Jeffrey A Ketterling1, Erwan Filoux.   

Abstract

Annular arrays provide a means to achieve enhanced image quality with a limited number of elements. Synthetic-focusing (SF) strategies that rely on beamforming data from individual transmit-to-receive (TR) element pairs provide a means to improve image quality without specialized TR delay electronics. Here, SF strategies are examined in the context of high-frequency ultrasound (>15 MHz) annular arrays composed of five elements, operating at 18 and 38 MHz. Acoustic field simulations are compared with experimental data acquired from wire and anechoic-sphere phantoms, and the values of lateral beamwidth, SNR, contrast-to-noise ratio (CNR), and depth of field (DOF) are compared as a function of depth. In each case, data were acquired for all TR combinations (25 in total) and processed with SF using all 25 TR pairs and SF with the outer receive channels removed one by one. The results show that removing the outer receive channels led to an overall degradation of lateral resolution, an overall decrease in SNR, and did not reduce the DOF, although the DOF profile decreased in amplitude. The CNR was >1 and remained fairly constant as a function of depth, with a slight decrease in CNR for the case with just the central element receiving. The relative changes between the calculated and measured quantities were nearly identical for the 18- and 38-MHz arrays. B-mode images of the anechoic phantom and an in vivo mouse embryo using full SF with 25 TR pairs or reduced TR-pair approaches showed minimal qualitative difference.

Entities:  

Mesh:

Year:  2012        PMID: 22899130      PMCID: PMC3422783          DOI: 10.1109/TUFFC.2012.2388

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  15 in total

1.  Unit-delay focusing architecture and integrated-circuit implementation for high-frequency ultrasound.

Authors:  James R Talman; Steven L Garverick; Christine E Morton; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

2.  A digital beamformer for high-frequency annular arrays.

Authors:  Jeremy A Brown; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-08       Impact factor: 2.725

3.  40-MHz annular array imaging of mouse embryos.

Authors:  Orlando Aristizábal; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

Review 4.  Synthetic aperture ultrasound imaging.

Authors:  Jørgen Arendt Jensen; Svetoslav Ivanov Nikolov; Kim Løkke Gammelmark; Morten Høgholm Pedersen
Journal:  Ultrasonics       Date:  2006-08-11       Impact factor: 2.890

5.  High-frequency ultrasound annular array imaging. Part II: digital beamformer design and imaging.

Authors:  Chang-Hong Hu; Kevin A Snook; Pei-Jie Cao; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

6.  GPU-based beamformer: fast realization of plane wave compounding and synthetic aperture imaging.

Authors:  Billy Y S Yiu; Ivan K H Tsang; Alfred C H Yu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-08       Impact factor: 2.725

7.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

8.  Annular array design and logarithmic processing for ultrasonic imaging.

Authors:  H E Melton; F L Thurstone
Journal:  Ultrasound Med Biol       Date:  1978       Impact factor: 2.998

9.  Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom.

Authors:  Erwan Filoux; Jonathan Mamou; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-05       Impact factor: 2.725

10.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion.

Authors:  G E Trahey; L F Nock
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

View more
  4 in total

1.  High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging.

Authors:  Erwan Filoux; Ashwin Sampathkumar; Parag V Chitnis; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  Rev Sci Instrum       Date:  2013-05       Impact factor: 1.523

2.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

3.  Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer.

Authors:  Parag V Chitnis; Orlando Aristizábal; Erwan Filoux; Ashwin Sampathkumar; Jonathan Mamou; Jeffrey A Ketterling
Journal:  Ultrason Imaging       Date:  2015-04-28       Impact factor: 1.578

4.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part II: Experimental Validation.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.