Literature DB >> 25925675

Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer.

Parag V Chitnis1, Orlando Aristizábal2, Erwan Filoux3, Ashwin Sampathkumar3, Jonathan Mamou3, Jeffrey A Ketterling3.   

Abstract

This paper presents an adaptive synthetic-focusing scheme that, when applied to photoacoustic (PA) data acquired using an annular array, improves focusing across a greater imaging depth and enhances spatial resolution. The imaging system was based on a 40-MHz, 5-element, annular-array transducer with a focal length of 12 mm and an 800-µm diameter hole through its central element to facilitate coaxial delivery of 532-nm laser. The transducer was raster-scanned to facilitate 3D acquisition of co-registered ultrasound and PA image data. Three synthetic-focusing schemes were compared for obtaining PA A-lines for each scan location: delay-and-sum (DAS), DAS weighted with a coherence factor (DAS + CF), and DAS weighted with a sign-coherence factor (DAS + SCF). Bench-top experiments that used an 80-µm hair were performed to assess the enhancement provided by the two coherence-based schemes. Both coherence-based schemes increased the signal-to-noise ratio by approximately 10 dB. When processed using the DAS-only scheme, the lateral dimension of the hair in a PA image with 20 dB dynamic range was between 300 µm and 1 mm for imaging depth ranging from 8 to 20 mm. In comparison, the DAS + CF scheme resulted in a lateral dimension of 200 to 450 µm over the same range. The DAS + SCF synthetic focusing further improved the smallest-resolvable dimension, which was between 150 and 400 µm over the same range of imaging depth. When used on PA data obtained from a 12-day-old mouse embryo, the DAS + SCF processing improved visualization of neurovasculature.
© The Author(s) 2015.

Entities:  

Keywords:  annular arrays; beamforming; coherence weighting; photoacoustic imaging

Mesh:

Year:  2015        PMID: 25925675      PMCID: PMC5002350          DOI: 10.1177/0161734615583981

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  19 in total

1.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

2.  Adaptive synthetic-aperture focusing technique for microvasculature imaging using photoacoustic microscopy.

Authors:  Zilin Deng; Xiaoquan Yang; Hui Gong; Qingming Luo
Journal:  Opt Express       Date:  2012-03-26       Impact factor: 3.894

3.  Optoacoustic imaging with synthetic aperture focusing and coherence weighting.

Authors:  C K Liao; M L Li; P C Li
Journal:  Opt Lett       Date:  2004-11-01       Impact factor: 3.776

4.  40-MHz annular array imaging of mouse embryos.

Authors:  Orlando Aristizábal; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

5.  Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer.

Authors:  Roger J Zemp; Rachel Bitton; Meng-Lin Li; K Kirk Shung; George Stoica; Lihong V Wang
Journal:  J Biomed Opt       Date:  2007 Jan-Feb       Impact factor: 3.170

6.  Adaptive beamforming for photoacoustic imaging.

Authors:  Suhyun Park; Andrei B Karpiouk; Salavat R Aglyamov; Stanislav Y Emelianov
Journal:  Opt Lett       Date:  2008-06-15       Impact factor: 3.776

7.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array.

Authors:  Srikant Vaithilingam; Te-Jen Ma; Yukio Furukawa; Ira O Wygant; Xuefeng Zhuang; Adam De La Zerda; Omer Oralkan; Aya Kamaya; Sanjiv S Gambhir; R Brooke Jeffrey; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

8.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

9.  Synthetic-focusing strategies for real-time annular-array imaging.

Authors:  Jeffrey A Ketterling; Erwan Filoux
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-08       Impact factor: 2.725

10.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

View more
  5 in total

1.  Backward-Mode Photoacoustic Imaging Using Illumination Through a CMUT With Improved Transparency.

Authors:  Xiao Zhang; Xun Wu; Oluwafemi Joel Adelegan; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

2.  Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging.

Authors:  Rashid Al Mukaddim; Rifat Ahmed; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

3.  Fiber-optic annular detector array for large depth of field photoacoustic macroscopy.

Authors:  Johannes Bauer-Marschallinger; Astrid Höllinger; Bernhard Jakoby; Peter Burgholzer; Thomas Berer
Journal:  Photoacoustics       Date:  2017-01-25

4.  Spatiotemporal Coherence Weighting for In Vivo Cardiac Photoacoustic Image Beamformation.

Authors:  Rashid Al Mukaddim; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

5.  Optical imaging of post-embryonic zebrafish using multi orientation raster scan optoacoustic mesoscopy.

Authors:  Murad Omar; Johannes Rebling; Kai Wicker; Tobias Schmitt-Manderbach; Mathias Schwarz; Jérôme Gateau; Hérnan López-Schier; Timo Mappes; Vasilis Ntziachristos
Journal:  Light Sci Appl       Date:  2017-01-13       Impact factor: 17.782

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.