Abstract

PURPOSE: We investigated the influence of beam modulation on treatment planning by comparing four available stereotactic radiosurgery (SRS) modalities: Gamma-Knife-Perfexion, Novalis-Tx Dynamic-Conformal-Arc (DCA) and Dynamic-Multileaf-Collimation-Intensity-Modulated-radiotherapy (DMLC-IMRT), and Cyberknife.
MATERIAL AND METHODS: Patients with arteriovenous malformation (n = 10) or acoustic neuromas (n = 5) were planned with different treatment modalities. Paddick conformity index (CI), dose heterogeneity (DH), gradient index (GI) and beam-on time were used as dosimetric indices.
RESULTS: Gamma-Knife-Perfexion can achieve high degree of conformity (CI = 0.77 ± 0.04) with limited low-doses (GI = 2.59 ± 0.10) surrounding the inhomogeneous dose distribution (D(H) = 0.84 ± 0.05) at the cost of treatment time (68.1 min ± 27.5). Novalis-Tx-DCA improved this inhomogeneity (D(H) = 0.30 ± 0.03) and treatment time (16.8 min ± 2.2) at the cost of conformity (CI = 0.66 ± 0.04) and Novalis-TX-DMLC-IMRT improved the DCA CI (CI = 0.68 ± 0.04) and inhomogeneity (D(H) = 0.18 ± 0.05) at the cost of low-doses (GI = 3.94 ± 0.92) and treatment time (21.7 min ± 3.4) (p<0.01). Cyberknife achieved comparable conformity (CI = 0.77 ± 0.06) at the cost of low-doses (GI = 3.48 ± 0.47) surrounding the homogeneous (D(H) = 0.22 ± 0.02) dose distribution and treatment time (28.4min±8.1) (p<0.01).
CONCLUSIONS: Gamma-Knife-Perfexion will comply with all SRS constraints (high conformity while minimizing low-dose spread). Multiple focal entries (Gamma-Knife-Perfexion and Cyberknife) will achieve better conformity than High-Definition-MLC of Novalis-Tx at the cost of treatment time. Non-isocentric beams (Cyberknife) or IMRT-beams (Novalis-Tx-DMLC-IMRT) will spread more low-dose than multiple isocenters (Gamma-Knife-Perfexion) or dynamic arcs (Novalis-Tx-DCA). Inverse planning and modulated fluences (Novalis-Tx-DMLC-IMRT and CyberKnife) will deliver the most homogeneous treatment. Furthermore, Linac-based systems (Novalis and Cyberknife) can perform image verification at the time of treatment delivery.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22884842     DOI: 10.1016/j.radonc.2012.07.002

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  23 in total

1.  Authors' reply to "Dosimetric of intracranial stereotactic radiosurgery: only 'an exercise of style'".

Authors:  Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian Ruge
Journal:  Strahlenther Onkol       Date:  2015-10       Impact factor: 3.621

2.  CyberKnife for Treatment of Vestibular Schwannoma: A Meta-analysis.

Authors:  Hossein Mahboubi; Ronald Sahyouni; Omid Moshtaghi; Kent Tadokoro; Yaser Ghavami; Kasra Ziai; Harrison W Lin; Hamid R Djalilian
Journal:  Otolaryngol Head Neck Surg       Date:  2017-04-25       Impact factor: 3.497

3.  Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform.

Authors:  Chuxiong Ding; Brian Hrycushko; Louis Whitworth; Xiang Li; Lucien Nedzi; Bradley Weprin; Ramzi Abdulrahman; Babu Welch; Steve B Jiang; Zabi Wardak; Robert D Timmerman
Journal:  Med Phys       Date:  2017-08-12       Impact factor: 4.071

4.  Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery: Comparison of dosimetric treatment plan quality.

Authors:  Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian Ruge
Journal:  Strahlenther Onkol       Date:  2014-11-22       Impact factor: 3.621

5.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

6.  Optimization by visualization of indices.

Authors:  Uwe Haverkamp; Darius Norkus; Jan Kriz; Mariam Müller Minai; Franz-Josef Prott; Hans Theodor Eich
Journal:  Strahlenther Onkol       Date:  2014-06-28       Impact factor: 3.621

7.  The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique.

Authors:  Xiaoyu Duan; William Giles; John P Kirkpatrick; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2019

8.  Dosimetric performance of two linear accelerator-based radiosurgery systems to treat single and multiplebrain metastases.

Authors:  Yoshihiro Ueda; Shingo Ohira; Hideya Yamazaki; Nobuhisa Mabuchi; Naokazu Higashinaka; Masayoshi Miyazaki; Teruki Teshima
Journal:  Br J Radiol       Date:  2019-06-12       Impact factor: 3.039

9.  Quantifying the trigger level of the vacuum surveillance system of the Gamma-Knife eXtend™ positioning system and evaluating the potential impact on dose delivery.

Authors:  Béatrice Reiner; Peter Bownes; David L Buckley; David I Thwaites
Journal:  J Radiosurg SBRT       Date:  2016

10.  Robotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformations.

Authors:  Sławomir Blamek; Aleksandra Grządziel; Leszek Miszczyk
Journal:  Radiat Oncol       Date:  2013-08-23       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.