Literature DB >> 22875172

Assessment of a transcatheter heart valve prosthesis with multidetector computed tomography: in vitro and in vivo imaging characteristics.

Linda M de Heer1, Jesse Habets, Jolanda Kluin, Pieter R Stella, Willem P Th M Mali, Lex A van Herwerden, Ricardo P J Budde.   

Abstract

Multidetector-row computed tomography (MDCT) image quality (IQ) of the commonly implanted Sapien prosthesis was assessed both in vitro and in vivo. The prosthesis was imaged in an in vitro model with a 256-slice CT system under pulsatile conditions using three protocols (1) retrospectively ECG-gating at 120 kV/600 mAs and (2) 140 kV/406 mAs, and (3) prospective triggering at 120 kV/210 mAs (10 acquisitions per protocol). After reconstruction in three perpendicular planes, IQ of the supra-,peri-,sub-,and intraprosthetic as well as leaflet regions was scored on a four-point scale (1 = non-diagnostic, 2 = moderate, 3 = good and 4 = excellent) by two observers. IQ was also assessed for twenty-one post-operative scans. The in vitro scans of the two retrospective protocols and twenty-one in vivo scans were analyzed during systole and diastole. The prospectively triggered scans were analyzed during diastole. Except for the valve leaflets in 5 systolic reconstructions, the in vitro scores were moderate to excellent. In vivo, 7 systolic and 3 diastolic reconstructions of the valve leaflets were non-diagnostic as well as 3 peri-prosthetic regions in diastole. All other scores were moderate to excellent. The Sapien prosthesis surrounded by a radiopaque stainless steel stent can be visualized with MDCT with moderate to good IQ, except for the valve leaflet region that has generally non-diagnostic or moderate IQ.

Entities:  

Mesh:

Year:  2012        PMID: 22875172     DOI: 10.1007/s10554-012-0111-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  23 in total

1.  Risk factors and outcome in European cardiac surgery: analysis of the EuroSCORE multinational database of 19030 patients.

Authors:  F Roques; S A Nashef; P Michel; E Gauducheau; C de Vincentiis; E Baudet; J Cortina; M David; A Faichney; F Gabrielle; E Gams; A Harjula; M T Jones; P P Pintor; R Salamon; L Thulin
Journal:  Eur J Cardiothorac Surg       Date:  1999-06       Impact factor: 4.191

2.  Transapical minimally invasive aortic valve implantation; the initial 50 patients.

Authors:  Thomas Walther; Volkmar Falk; Jörg Kempfert; Michael A Borger; Jens Fassl; Michael W A Chu; Gerhard Schuler; Friedrich W Mohr
Journal:  Eur J Cardiothorac Surg       Date:  2008-02-21       Impact factor: 4.191

3.  The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience.

Authors:  Eli Konen; Orly Goitein; Micha S Feinberg; Yael Eshet; Ehud Raanani; Uri Rimon; Elio Di-Segni
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

4.  Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis.

Authors:  Carl J Schultz; Annick Weustink; Nicolo Piazza; Amber Otten; Nico Mollet; Gabriel Krestin; Robert J van Geuns; Pim de Feyter; Patrick W J Serruys; Peter de Jaegere
Journal:  J Am Coll Cardiol       Date:  2009-09-01       Impact factor: 24.094

5.  Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation.

Authors:  Ralf Koos; Ertunc Altiok; Andreas Horst Mahnken; Mirja Neizel; Guido Dohmen; Nikolaus Marx; Harald Kühl; Rainer Hoffmann
Journal:  Int J Cardiol       Date:  2011-02-18       Impact factor: 4.164

6.  Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves.

Authors:  Petr Symersky; Ricardo P J Budde; Mathias Prokop; Bas A J M de Mol
Journal:  J Heart Valve Dis       Date:  2011-03

7.  Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: comparison with transthoracic echocardiography.

Authors:  Fabien Chenot; Patrick Montant; Céline Goffinet; Agnès Pasquet; David Vancraeynest; Emmanuel Coche; Jean-Louis Vanoverschelde; Bernhard L Gerber
Journal:  Radiology       Date:  2009-12-17       Impact factor: 11.105

8.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.

Authors:  Laurens F Tops; David A Wood; Victoria Delgado; Joanne D Schuijf; John R Mayo; Sanjeevan Pasupati; Frouke P L Lamers; Ernst E van der Wall; Martin J Schalij; John G Webb; Jeroen J Bax
Journal:  JACC Cardiovasc Imaging       Date:  2008-05

9.  Role of multislice computed tomography in transcatheter aortic valve replacement.

Authors:  David A Wood; Laurens F Tops; John R Mayo; Sanjeevan Pasupati; Martin J Schalij; Karin Humphries; May Lee; Abdullah Al Ali; Brad Munt; Rob Moss; Christopher R Thompson; Jeroen J Bax; John G Webb
Journal:  Am J Cardiol       Date:  2009-05-01       Impact factor: 2.778

10.  Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients.

Authors:  Jesse Habets; Petr Symersky; Lex A van Herwerden; Bas A J M de Mol; Anje M Spijkerboer; Willem P Th M Mali; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2011-01-29       Impact factor: 5.315

View more
  2 in total

Review 1.  Cardiovascular imaging 2012 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2013-04       Impact factor: 2.357

2.  Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes.

Authors:  Dominika Suchá; Steven A J Chamuleau; Petr Symersky; Matthijs F L Meijs; Renee B A van den Brink; Bas A J M de Mol; Willem P Th M Mali; Jesse Habets; Lex A van Herwerden; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2015-10-16       Impact factor: 5.315

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.