Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis.

Carl J Schultz1, Annick Weustink, Nicolo Piazza, Amber Otten, Nico Mollet, Gabriel Krestin, Robert J van Geuns, Pim de Feyter, Patrick W J Serruys, Peter de Jaegere.   

Abstract

OBJECTIVES: Using multislice computed tomography (MSCT), we sought to evaluate the geometry and apposition of the CoreValve ReValving System (CRS, Medtronic, Luxembourgh, Luxembourgh) in patients with aortic stenosis.
BACKGROUND: There are no data on the durability of percutaneous aortic valve replacement. Geometric factors may affect durability.
METHODS: Thirty patients had MSCT at a median 1.5 months (interquartile range [IQR] 0 to 7 months) after percutaneous aortic valve replacement. Axial dimensions and apposition of the CRS were evaluated at 4 levels: 1) the ventricular end; 2) the nadir; 3) central coaptation of the CRS leaflets; and 4) commissures. Orthogonal smallest and largest diameters and cross-sectional surface area were measured at each level.
RESULTS: The CRS (26-mm: n = 14, 29-mm: n = 16) was implanted at 8.5 mm (IQR 5.2 to 11.0 mm) below the noncoronary sinus. None of the CRS frames reached nominal dimensions. The difference between measured and nominal cross-sectional surface area at the ventricular end was 1.6 cm(2) (IQR 0.9 to 2.6 cm(2)) and 0.5 cm(2) (IQR 0.2 to 0.7 cm(2)) at central coaptation. At the level of central coaptation the CRS was undersized relative to the native annulus by 24% (IQR 15% to 29%). The difference between the orthogonal smallest and largest diameters (degree of deformation) at the ventricular end was 4.4 mm (IQR 3.3 to 6.4 mm) and it decreased progressively toward the outflow. Incomplete apposition of the CRS frame was present in 62% of patients at the ventricular end and was ubiquitous at the central coaptation and higher.
CONCLUSIONS: Dual-source MSCT demonstrated incomplete and nonuniform expansion of the CRS frame, but the functionally important mid-segment was well expanded and almost symmetrical. Undersizing and incomplete apposition were seen in the majority of patients.

Entities:  

Mesh:

Year:  2009        PMID: 19712801     DOI: 10.1016/j.jacc.2009.04.075

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  23 in total

Review 1.  Guidance of transcatheter aortic valve replacement by echocardiography.

Authors:  Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

2.  [Imaging technique and current status of valvular heart disease using cardiac MRI].

Authors:  J Lotz; J M Sohns
Journal:  Radiologe       Date:  2013-10       Impact factor: 0.635

3.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

4.  Assessment of a transcatheter heart valve prosthesis with multidetector computed tomography: in vitro and in vivo imaging characteristics.

Authors:  Linda M de Heer; Jesse Habets; Jolanda Kluin; Pieter R Stella; Willem P Th M Mali; Lex A van Herwerden; Ricardo P J Budde
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-09       Impact factor: 2.357

Review 5.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

6.  Hemodynamic Impact of Transcatheter Aortic Valve Deployment Configuration.

Authors:  Eric Sirois; Kewei Li; Joe Calderan; Lisong Ai; Wei Sun
Journal:  J Med Device       Date:  2013-12-05       Impact factor: 0.582

Review 7.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

8.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root.

Authors:  Wenbin Mao; Qian Wang; Susheel Kodali; Wei Sun
Journal:  J Biomech Eng       Date:  2018-10-01       Impact factor: 2.097

Review 9.  Transcatheter aortic valve implantation: current and future approaches.

Authors:  Josep Rodés-Cabau
Journal:  Nat Rev Cardiol       Date:  2011-11-15       Impact factor: 32.419

Review 10.  Annular Rupture During Transcatheter Aortic Valve Implantation: Predictors, Management and Outcomes.

Authors:  J J Coughlan; Thomas Kiernan; Darren Mylotte; Samer Arnous
Journal:  Interv Cardiol       Date:  2018-09