Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective.

Antonis Kalemis1, Bénédicte M A Delattre, Susanne Heinzer.   

Abstract

PET and MRI are established clinical tools which provide complementary information, but clinical workflow limits widespread clinical application of both modalities in combination. The two modalities are usually situated in different hospital departments and operated and reported independently, and patients are referred for both scans, often consecutively. With the advent of PET/MR as a new hybrid imaging modality there is now a possibility of addressing these concerns. There are two different design philosophies for integrated PET/MR imaging-positioning PET inside the MRI magnet or in tandem, similar to PET/CT. The Ingenuity TF PET/MR by Philips Healthcare is a sequential PET/MR tomograph combining state-of-the-art time-of-flight PET and high-field MRI with parallel transmission capabilities. In this review article we describe the technology implemented in the system, for example RF and magnetic shielding, MR-based attenuation correction, peculiarities in scatter correction, MR system optimisation, and the philosophy behind its design. Furthermore, we provide an overview of how the system has been used during the last two years, and expectations of how the use of PET/MR may continue in the years to come. On the basis of these observations and experiences we discuss the utility of the system, clinical workflow and acquisition times, and possible ways of optimization.

Entities:  

Mesh:

Year:  2012        PMID: 22868642     DOI: 10.1007/s10334-012-0330-y

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  84 in total

1.  Molecular imaging with PET--the future challenges.

Authors:  T Jones
Journal:  Br J Radiol       Date:  2002-11       Impact factor: 3.039

2.  Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA.

Authors:  Jing-Yu Cui; Guillem Pratx; Sven Prevrhal; Craig S Levin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

Review 3.  An outlook on future design of hybrid PET/MRI systems.

Authors:  Habib Zaidi; Alberto Del Guerra
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Relative capability of MR imaging and FDG PET to depict changes associated with prodromal and early Alzheimer disease.

Authors:  David S Karow; Linda K McEvoy; Christine Fennema-Notestine; Donald J Hagler; Robin G Jennings; James B Brewer; Carl K Hoh; Anders M Dale
Journal:  Radiology       Date:  2010-09       Impact factor: 11.105

5.  A PET-MRI case of corticocerebellar diaschisis after stroke.

Authors:  Valentina Garibotto; Maria I Vargas; Karl-Olof Lovblad; Osman Ratib
Journal:  Clin Nucl Med       Date:  2011-09       Impact factor: 7.794

6.  Correlation of inflammation assessed by 18F-FDG PET, active mineral deposition assessed by 18F-fluoride PET, and vascular calcification in atherosclerotic plaque: a dual-tracer PET/CT study.

Authors:  Thorsten Derlin; Zoltán Tóth; László Papp; Christian Wisotzki; Ivayla Apostolova; Christian R Habermann; Janos Mester; Susanne Klutmann
Journal:  J Nucl Med       Date:  2011-06-16       Impact factor: 10.057

7.  Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner.

Authors:  Gaspar Delso; Sebastian Fürst; Björn Jakoby; Ralf Ladebeck; Carl Ganter; Stephan G Nekolla; Markus Schwaiger; Sibylle I Ziegler
Journal:  J Nucl Med       Date:  2011-11-11       Impact factor: 10.057

8.  PET/CT and 3-T whole-body MRI in the detection of malignancy in treated oropharyngeal and hypopharyngeal carcinoma.

Authors:  Shu-Hang Ng; Sheng-Chieh Chan; Tzu-Chen Yen; Chun-Ta Liao; Chin-Yu Lin; Joseph Tung-Chieh Chang; Sheung-Fat Ko; Hung-Ming Wang; Kai-Ping Chang; Kang-Hsing Fan
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-15       Impact factor: 9.236

9.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

10.  Comparison of grey matter and metabolic reductions in frontotemporal dementia using FDG-PET and voxel-based morphometric MR studies.

Authors:  Tomonori Kanda; Kazunari Ishii; Takafumi Uemura; Naokazu Miyamoto; Toshiki Yoshikawa; Atsushi K Kono; Etsuro Mori
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-26       Impact factor: 9.236

View more
  23 in total

Review 1.  Clinical and research applications of simultaneous positron emission tomography and MRI.

Authors:  F Fraioli; S Punwani
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

2.  Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging.

Authors:  David Izquierdo-Garcia; Stephen J Sawiak; Karin Knesaurek; Jagat Narula; Valentin Fuster; Joseph Machac; Zahi A Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-21       Impact factor: 9.236

3.  mDixon-Based Synthetic CT Generation for PET Attenuation Correction on Abdomen and Pelvis Jointly Using Transfer Fuzzy Clustering and Active Learning-Based Classification.

Authors:  Pengjiang Qian; Yangyang Chen; Jung-Wen Kuo; Yu-Dong Zhang; Yizhang Jiang; Kaifa Zhao; Rose Al Helo; Harry Friel; Atallah Baydoun; Feifei Zhou; Jin Uk Heo; Norbert Avril; Karin Herrmann; Rodney Ellis; Bryan Traughber; Robert S Jones; Shitong Wang; Kuan-Hao Su; Raymond F Muzic
Journal:  IEEE Trans Med Imaging       Date:  2019-08-16       Impact factor: 10.048

Review 4.  Clinical oncologic applications of PET/MRI: a new horizon.

Authors:  Sasan Partovi; Andres Kohan; Christian Rubbert; Jose Luis Vercher-Conejero; Chiara Gaeta; Roger Yuh; Lisa Zipp; Karin A Herrmann; Mark R Robbin; Zhenghong Lee; Raymond F Muzic; Peter Faulhaber; Pablo R Ros
Journal:  Am J Nucl Med Mol Imaging       Date:  2014-03-20

5.  Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer.

Authors:  Josefine S Kornerup; Patrik Brodin; Charlotte Birk Christensen; Thomas Björk-Eriksson; Anne Kiil-Berthelsen; Lise Borgwardt; Per Munck Af Rosenschöld
Journal:  Pediatr Radiol       Date:  2014-11-07

6.  Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI.

Authors:  Sune H Keller; Søren Holm; Adam E Hansen; Bernhard Sattler; Flemming Andersen; Thomas L Klausen; Liselotte Højgaard; Andreas Kjær; Thomas Beyer
Journal:  MAGMA       Date:  2012-09-21       Impact factor: 2.310

7.  MR/PET or PET/MRI: does it matter?

Authors:  Thomas Beyer; Ewald Moser
Journal:  MAGMA       Date:  2013-02-06       Impact factor: 2.310

8.  Clinical utility of 18F-FDG-PET/MR for preoperative breast cancer staging.

Authors:  Diomidis Botsikas; Anastasia Kalovidouri; Minerva Becker; Michele Copercini; Dahila Amal Djema; Alexandre Bodmer; Sindy Monnier; Christoph D Becker; Xavier Montet; Benedicte M A Delattre; Osman Ratib; Valentina Garibotto; Claire Tabouret-Viaud
Journal:  Eur Radiol       Date:  2015-10-17       Impact factor: 5.315

9.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

Review 10.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.