Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor.

S W Hughes1, T J D'Arcy, D J Maxwell, W Chiu, A Milner, J E Saunders, R J Sheppard.   

Abstract

A system is described for calculating volume from a sequence of multiplanar 2D ultrasound images. Ultrasound images are captured using a video digitising card (Hauppauge Win/TV card) installed in a personal computer, and regions of interest transformed into 3D space using position and orientation data obtained from an electromagnetic device (Polhemus, Fastrak). The accuracy of the system was assessed by scanning 10 water filled balloons (13-141 mL), 10 kidneys (147-200 mL) and 16 fetal livers (8-37 mL) in water using an Acuson 128XP/10 (5 MHz curvilinear probe). Volume was calculated using the ellipsoid, planimetry, tetrahedral and ray tracing methods and compared with the actual volume measured by weighing (balloons) and water displacement (kidneys and livers). The mean percentage error for the ray tracing method was 0.9 +/- 2.4%, 2.7 +/- 2.3%, 6.6 +/- 5.4% for balloons, kidneys and livers, respectively. So far the system has been used clinically to scan fetal livers and lungs, neonate brain ventricles and adult prostate glands.

Entities:  

Mesh:

Year:  1996        PMID: 8865553     DOI: 10.1016/0301-5629(96)00022-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

Review 1.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

2.  What does 2-dimensional imaging add to 3- and 4-dimensional obstetric ultrasonography?

Authors:  Luís F Gonçalves; Jyh Kae Nien; Jimmy Espinoza; Juan Pedro Kusanovic; Wesley Lee; Betsy Swope; Eleazar Soto; Marjorie C Treadwell; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-06       Impact factor: 2.153

3.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

4.  Automatic virtual transducer locating system to assist in interpreting ultrasound imaging.

Authors:  Nobuyuki Taniguchi; Tomoyuki Kuwata; Tomoko Ono; Kouichi Itoh; Kiyoka Omoto; Yasutomo Fujii; Akifumi Ootake
Journal:  J Med Ultrason (2001)       Date:  2003-12       Impact factor: 1.314

Review 5.  Advances in fetal cardiac imaging.

Authors:  M Sklansky
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

6.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.