Literature DB >> 31545718

Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Jaesok Yu, Heechul Yoon, Yousuf M Khalifa, Stanislav Y Emelianov.   

Abstract

Ultrasound imaging using a matrix array allows real-time multi-planar volumetric imaging. To enhance image quality, the matrix array should provide fast volumetric ultrasound imaging with spatially consistent focusing in the lateral and elevational directions. However, because of the significantly increased data size, dealing with massive and continuous data acquisition is a significant challenge. We have designed an imaging acquisition sequence that handles volumetric data efficiently using a single 256-channel Verasonics ultrasound research platform multiplexed with a 1024-element matrix array. The developed sequence has been applied for building an ultrasonic pupilometer. Our results demonstrate the capability of the developed approach for structural visualization of an ex vivo porcine eye and the temporal response of the modeled eye pupil with moving iris at the volume rate of 30 Hz. Our study provides a fundamental ground for researchers to establish their own volumetric ultrasound imaging platform and could stimulate the development of new volumetric ultrasound approaches and applications.

Entities:  

Mesh:

Year:  2019        PMID: 31545718      PMCID: PMC7008949          DOI: 10.1109/TUFFC.2019.2942557

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  36 in total

Review 1.  The parameters of the porcine eyeball.

Authors:  Irene Sanchez; Raul Martin; Fernando Ussa; Ivan Fernandez-Bueno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-02-02       Impact factor: 3.117

2.  ULA-OP: an advanced open platform for ultrasound research.

Authors:  Piero Tortoli; Luca Bassi; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-10       Impact factor: 2.725

3.  3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamforming.

Authors:  Morten Fischer Rasmussen; Thomas Lehrmann Christiansen; Erik Vilain Thomsen; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-05       Impact factor: 2.725

Review 4.  Freehand 3-D Ultrasound Imaging: A Systematic Review.

Authors:  Mohammad Hamed Mozaffari; Won-Sook Lee
Journal:  Ultrasound Med Biol       Date:  2017-07-14       Impact factor: 2.998

5.  SARUS: A Synthetic Aperture Real-time Ultrasound System.

Authors:  Jørgen Arendt Jensen; Hans Holten-Lund; Ronnie Thorup Nilsson; Martin Hansen; Ulrik Darling Larsen; Rune Petter Domsten; Borislav Gueorguiev Tomov; Matthias Bo Stuart; Svetoslav Ivanov Nikolov; Michael Johannes Pihl; Yigang Du; Joachim Hee Rasmussen; Morten Fischer Rasmussen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

6.  The current status of ophthalmic B-scan ultrasonography.

Authors:  Y L Fisher
Journal:  J Clin Ultrasound       Date:  1975-09       Impact factor: 0.910

7.  The pupillary light reflex in normal subjects.

Authors:  C J Ellis
Journal:  Br J Ophthalmol       Date:  1981-11       Impact factor: 4.638

8.  NIH Image to ImageJ: 25 years of image analysis.

Authors:  Caroline A Schneider; Wayne S Rasband; Kevin W Eliceiri
Journal:  Nat Methods       Date:  2012-07       Impact factor: 28.547

9.  GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

Authors:  Jung Woo Choe; Amin Nikoozadeh; Omer Oralkan; Butrus T Khuri-Yakub
Journal:  IEEE Trans Med Imaging       Date:  2013-03-18       Impact factor: 10.048

10.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

View more
  3 in total

1.  Synchronization of RF Data in Ultrasound Open Platforms (UOPs) for High-Accuracy and High-Resolution Photoacoustic Tomography Using the "Scissors" Programming Method.

Authors:  Lei Fu; Zhicheng Jin; Baiyan Qi; Wonjun Yim; Zhuohong Wu; Tengyu He; Jesse V Jokerst
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-05-26       Impact factor: 3.267

Review 2.  Current Development and Applications of Super-Resolution Ultrasound Imaging.

Authors:  Qiyang Chen; Hyeju Song; Jaesok Yu; Kang Kim
Journal:  Sensors (Basel)       Date:  2021-04-01       Impact factor: 3.576

3.  3D transcranial ultrasound localization microscopy for discrimination between ischemic and hemorrhagic stroke in early phase.

Authors:  Arthur Chavignon; Vincent Hingot; Cyrille Orset; Denis Vivien; Olivier Couture
Journal:  Sci Rep       Date:  2022-08-26       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.