Literature DB >> 8567138

Revision arthroplasty with an isoelastic uncemented femoral stem.

T J Niinimäki1, J P Puranen, P K Jalovaara.   

Abstract

We carried out 102 hip revision arthroplasties using an uncemented isoelastic femoral stem on 92 patients between 1985 and 1989. The proximal femoral bone stock had deteriorated in 45%. Eleven patients died during the mean follow up of 5.7 years. The femoral component has been revised again for loosening in 13, for infection in 5 and for dislocation in 3. Radiographs of 70 hips showed incipient migration at 3 months in 20, and at the time of review 27 hips had migrated 5 mm or more. Nine stems had migrated more than 8 mm and were judged to be loose. There were 11 fractures before operation and 15 during operation; they all healed. Slight cortical hypertrophy of not more than 2 mm was present in most cases. Three patients (4 hips) were excluded because of severe systemic illness. Of the remaining 66 hips, the clinical outcome was excellent in 18%, good in 50%, fair in 26% and poor in 6%. The isoelastic stem is associated with poor primary fixation which is indicated by early subsidence. The results, with a total failure rate of 33%, are unsatisfactory and the isoelastic femoral stem used in this series cannot be recommended for revision operations.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8567138     DOI: 10.1007/bf00181114

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  34 in total

1.  Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits.

Authors:  P Aspenberg; S Goodman; S Toksvig-Larsen; L Ryd; T Albrektsson
Journal:  Acta Orthop Scand       Date:  1992-04

2.  Unsatisfactory results after repeated revision of hip arthroplasty. 61 cases followed for 5 (1-10) years.

Authors:  J B Retpen; J E Varmarken; N D Röck; J S Jensen
Journal:  Acta Orthop Scand       Date:  1992-04

3.  [Results of 5-7 year follow-up of implantation of RM isoelastic hip endoprosthesis].

Authors:  D Träger
Journal:  Unfallchirurg       Date:  1989-06       Impact factor: 1.000

4.  Observations on the effect of movement on bone ingrowth into porous-surfaced implants.

Authors:  R M Pilliar; J M Lee; C Maniatopoulos
Journal:  Clin Orthop Relat Res       Date:  1986-07       Impact factor: 4.176

5.  The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component.

Authors:  J L Lewis; M J Askew; R L Wixson; G M Kramer; R R Tarr
Journal:  J Bone Joint Surg Am       Date:  1984-02       Impact factor: 5.284

6.  Definition of endoprosthetic loosening. Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips.

Authors:  B Mjöberg; J Brismar; L I Hansson; H Pettersson; G Selvik; R Onnerfält
Journal:  Acta Orthop Scand       Date:  1985-12

7.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

8.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

9.  Revision total hip arthroplasty. Long-term results without cement.

Authors:  J M Lawrence; C A Engh; G E Macalino
Journal:  Orthop Clin North Am       Date:  1993-10       Impact factor: 2.472

10.  Cementless R.M. isoelastic total hip prosthesis in revision surgery for loose prostheses.

Authors:  M Gerundini; U Fusco; A Avai; G Maistrelli
Journal:  Ital J Orthop Traumatol       Date:  1987-06
View more
  2 in total

1.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

2.  Total hip replacement arthroplasty with Mallory-Head system--minimum ten-year follow-up results.

Authors:  Joo-Hyoun Song; Dong-Hyun Kim; Juyoung Kim
Journal:  Int Orthop       Date:  2012-08-04       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.