Literature DB >> 2199114

Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components.

C A Engh1, P Massin, K E Suthers.   

Abstract

Certain roentgenographic signs have value in predicting the fixation of a cementless femoral component to bone by osseointegration. Other signs have value in predicting the gross stability of a cementless femoral component. The authors have determined the specificity and sensitivity of the signs for osseointegration in cases in which the histologic fixation has been confirmed after implant removal. The authors have also determined the specificity and sensitivity of the signs for gross implant stability in cases in which the stability has been confirmed at reoperation. Statistical methods were used to determine a numeric value for each of these roentgenographic signs, and these values were combined into a score. The score was divided into fixation by osseointegration and mechanical implant stability. The two scores were then combined into an overall score. When signs of osseointegration were present, the implant was always stable, and the overall scores were the highest. When signs of osseointegration were absent, the mechanical stability varied, and the scores were lower. A neutral or slightly negative score correlated with failed osseointegration but secondary successful implant stabilization. A very low negative score correlated with gross implant instability. To confirm the validity of the scoring system, the two-year postoperative score was determined for 1005 cases in which the clinical outcome was known. A strong correlation between the presence of symptoms and a low score confirmed the value of the scoring system for diagnosing implant loosening as the cause of symptoms. As a second test, the two-year and five-year postoperative results were compared in the same patients. A high two-year score correlated with durable implant stability through five years. A low two-year score correlated with a higher incidence of late symptomatic loosening.

Entities:  

Mesh:

Year:  1990        PMID: 2199114

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  252 in total

1.  Comparison of wear and osteolysis in hip replacement using two different coatings of the femoral stem.

Authors:  Joaquin Sanchez-Sotelo; David G Lewallen; William Scott Harmsen; Jeffrey Harrington; Miguel E Cabanela
Journal:  Int Orthop       Date:  2004-04-29       Impact factor: 3.075

2.  Second-generation annealed highly cross-linked polyethylene exhibits low wear.

Authors:  James A D'Antonio; William N Capello; Rama Ramakrishnan
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

3.  Hip resurfacing in patients who have osteonecrosis and are 25 years or under.

Authors:  Siraj A Sayeed; Aaron J Johnson; D Alex Stroh; Thomas P Gross; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

Review 5.  Assessment of fixation in cementless femoral revision of total hip arthroplasty: comparison of the Engh score versus radiolucent line measurement.

Authors:  Olivier Roche; Julien Girard; François Canovas; Henri Migaud; François Bonnomet; Mathias Goldschild; Pierre Le Béguec
Journal:  Int Orthop       Date:  2015-11-17       Impact factor: 3.075

6.  Anterior approach for total hip arthroplasty conversion of hip fusion.

Authors:  Caroline Scemama; Vincent Lestrat; Benoit Combourieu; Thierry Judet
Journal:  Int Orthop       Date:  2015-12-28       Impact factor: 3.075

7.  Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients.

Authors:  Jonathan Hutt; Ziad Harb; Ian Gill; Fadhil Kashif; John Miller; Matthew Dodd
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

8.  Cementless total hip arthroplasty for patients previously treated with femoral osteotomy for hip dysplasia: the incidence of periprosthetic fracture.

Authors:  Masanobu Ohishi; Yasuharu Nakashima; Takuaki Yamamoto; Goro Motomura; Jun-Ichi Fukushi; Satoshi Hamai; Yusuke Kohno; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2015-09-19       Impact factor: 3.075

9.  Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

Authors:  Sujee Jeyapalina; James Peter Beck; Kent N Bachus; Ornusa Chalayon; Roy D Bloebaum
Journal:  Clin Orthop Relat Res       Date:  2014-10       Impact factor: 4.176

10.  Effects of titanium particle size on osteoblast functions in vitro and in vivo.

Authors:  Moon G Choi; Hae S Koh; Daniel Kluess; Daniel O'Connor; Anshu Mathur; George A Truskey; Janet Rubin; David X F Zhou; K-L Paul Sung
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-08       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.