Literature DB >> 2286204

Simultaneous measurement of left ventricular function and perfusion.

A T Elliott1, J H McKillop, S D Pringle, G J Gillen, J T Wilson, A R Lorimer, H J Dargie.   

Abstract

A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2286204     DOI: 10.1007/bf01268021

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  3 in total

1.  Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.

Authors:  R D Okada; D Glover; T Gaffney; S Williams
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

2.  Factors that affect the reproducibility of measurements of left ventricular function from first-pass radionuclide ventriculograms.

Authors:  D S Dymond; A Elliott; D Stone; G Hendrix; R Spurrell
Journal:  Circulation       Date:  1982-02       Impact factor: 29.690

3.  Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201.

Authors:  A J Sinusas; G A Beller; W H Smith; E L Vinson; V Brookeman; D D Watson
Journal:  J Nucl Med       Date:  1989-09       Impact factor: 10.057

  3 in total
  4 in total

Review 1.  Measurement of ventricular function with radionuclide techniques.

Authors:  Kim A Williams
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

2.  Gated planar technetium 99m-labeled sestamibi myocardial perfusion image inversion for quantitative scintigraphic assessment of left ventricular function.

Authors:  K A Williams; L A Taillon
Journal:  J Nucl Cardiol       Date:  1995 Jul-Aug       Impact factor: 5.952

3.  Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; C Benjamin; A Gagnon
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

4.  Amplitude analysis of stress technetium-99m methoxy isobutylisonitrile images in coronary artery disease.

Authors:  E E Camargo; F H Hironaka; M C Giorgi; J Soares Júnior; J C Meneguetti; R Abe; C C Robilotta; A C Munhoz; H Checchi; J A Ramirez
Journal:  Eur J Nucl Med       Date:  1992
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.