Literature DB >> 3338137

Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.

R D Okada1, D Glover, T Gaffney, S Williams.   

Abstract

To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored by miniature implantable radiation detectors for 4 hr after administration of the isotope. The dogs were then killed. Serial gamma camera images were also acquired during the study. Heart rate, arterial blood pressure, pressure distal to the stenosis, and cardiac output did not change significantly during the experiment. Microsphere-determined regional myocardial blood flow was significantly reduced in the left circumflex distribution in the 12 dogs with coronary artery stenoses. In the 12 dogs with left circumflex coronary artery stenoses, the 4 hr fractional Tc-MIBI clearances from the normal and ischemic zones were minimal and equivalent (0.15 +/- 0.05 vs 0.15 +/- 0.07). In the eight control dogs, 4 hr fractional Tc-MIBI clearances from the left anterior descending and left circumflex artery zones were minimal and equivalent (0.11 +/- 0.06 vs 0.10 +/- 0.07). Four hour fractional Tc-MIBI clearance from the blood was 0.98 +/- 0.03 for the dogs with stenosis and 0.97 +/- 0.02 for the dogs without stenosis. One additional dog had complete occlusion of the left circumflex coronary artery followed by administration of Tc-MIBI and scandium-46-labeled microspheres. This heart was immediately sectioned and counted to determine the relationship of regional blood flow to Tc-MIBI distribution (r = .92).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3338137     DOI: 10.1161/01.cir.77.2.491

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  90 in total

1.  Functional assessment of coronary artery stenosis by doppler derived absolute and relative coronary blood flow velocity reserve in comparison with (99m)Tc MIBI SPECT.

Authors:  H J Verberne; J J Piek; R A van Liebergen; K T Koch; J M Schroeder-Tanka; E A van Royen
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  The challenge of quantifying defect size and severity: reality versus algorithm.

Authors:  R L Eisner; R E Patterson
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

Review 3.  An overview of radiotracers in nuclear cardiology.

Authors:  W Acampa; C Di Benedetto; A Cuocolo
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

Review 4.  Myocardial perfusion imaging agents: SPECT and PET.

Authors:  George A Beller; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

Review 5.  Acute rest myocardial perfusion imaging for chest pain.

Authors:  Michael C Kontos; Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

Review 6.  Role of nuclear cardiac imaging in myocardial infarction: postinfarction risk stratification.

Authors:  John J Mahmarian; Girish Dwivedi; Tultul Lahiri
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

7.  Measuring myocardium at risk in acute myocardial infarction--a continuing challenge.

Authors:  Todd D Miller; Raymond J Gibbons
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

8.  Assessment of Regional Viability in the Infarct Zone Following Myocardial Infarction.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1997       Impact factor: 2.300

9.  Assessment of area at risk and efficacy of treatment in patients with acute coronary syndrome using 99mTc tetrofosmin imaging in humans.

Authors:  H Matsuo; S Watanabe; Y Nishida; T Matsubara; M Kano; A Sugiyama; Y Matsuno; H Oda; Y Kotoo; H Oohashi
Journal:  Ann Nucl Med       Date:  1993-11       Impact factor: 2.668

10.  Preliminary evaluation in humans of Tc-99m-Q3, a new tracer for myocardial perfusion imaging.

Authors:  G Bisi; R Sciagrà; L Bacciottini; D Antoniucci; G M Santoro; P Buonamici; C Bonino
Journal:  Int J Card Imaging       Date:  1993-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.